Atrial function analysis after percutaneous umbrella device and suture-mediated patent fossa ovalis closure

被引:4
|
作者
Tarsia, Carmela [1 ]
Gaspardone, Carlo [2 ]
Sgueglia, Gregory A. [1 ]
De Santis, Antonella [1 ]
D'ascoli, Emanuela [1 ]
Piccioni, Fabiana [1 ]
Iamele, Maria [1 ]
Posteraro, Giuseppe A. [1 ]
Cinque, Alessandra [1 ]
Gaspardone, Achille [1 ,3 ]
机构
[1] St Eugenio Hosp, Unit Cardiol, Rome, Italy
[2] Univ Vita Salute San Raffaele, Milan, Italy
[3] St Eugenio Hosp, Unit Cardiol, Piazzale Umanesimo 10, I-00144 Rome, Italy
关键词
Atrial function; Cardiology; Septal occluder device; STRAIN-RATE; FORAMEN; ECHOCARDIOGRAPHY; OUTCOMES; THERAPY;
D O I
10.23736/S2724-5683.21.05710-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Atrial fibrillation is an undesirable event following percutaneous patent fossa ovalis (PFO) closure with metallic occluders, suggesting that implanting a rigid closure device could alter atrial function. Suture-mediated PFO closure is a new technique, achieving closure of the PFO by means of a simple suture. Aim of this study was to evaluate left atrial function after closure of PFO by direct suture and traditional occluders.METHODS: We studied 40 age and sex homogeneous patients, 20 undergoing PFO closure by device (OCL) and 20 by suturing (NS). Twenty healthy sex-age matched subjects made up the control group (CT). Left atrial function was evaluated by using volumetric and speckle-tracking analysis assessing the following parameters: total emptying fraction (EF), Expansion Index (EI), active emptying fraction (AEF), strain values of the reservoir (r-ED), conduit (cd-ED) and contraction phase (ct-ED).RESULTS: Compared to CT and NS, OCL patients had significantly worst indices of left atrial reservoir function (EF P=0.001, EI P=0.003, r-ED P<0.001), conduit function (cd-ED P=0.018) and contraction function (AEF P=0.010; ct-ED P<0.001). No significant differences were observed in left atrial function indices between CT and NS patients. CONCLUSIONS: Suture-mediated PFO closure does not alter left atrial function. Conversely, metallic occluder is as-sociated with worse left atrium function. This detrimental effect on atrial function could favor the development of atrial arrhythmias.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 50 条
  • [21] Suture-mediated closure devices for percutaneous endovascular abdominal aneurysm repair
    Szpotan, Tomasz
    Czernik, Maciej
    Majos, Agata
    POLISH JOURNAL OF RADIOLOGY, 2023, 88 : E47 - E52
  • [22] Percutaneous suture-mediated patent foramen ovale closure: two-year clinical follow-up
    Gaspardone, Achille
    Cinque, Alessandra
    Beggio, Elisa
    De Santis, Antonella
    D'ascoli, Emanuela
    Piccioni, Fabiana
    Iamele, Maria
    Sgueglia, Gregory A.
    Gaspardone, Carlo
    Di Matteo, Antonio
    Versaci, Francesco
    MINERVA CARDIOLOGY AND ANGIOLOGY, 2023, 71 (02) : 169 - 174
  • [23] Initial experience using The Closer: A new device for percutaneous suture-mediated closure of arterial puncture sites
    Hahn, U
    Betsch, A
    Tepe, G
    Koenig, CW
    Wiskirchen, J
    Duda, SH
    RADIOLOGY, 2000, 217 : 380 - 380
  • [24] Suture-mediated percutaneous closure of the arterial puncture site after abdominal aortic stent implantation
    Wiskirchen, J
    Duda, SH
    Steger, V
    Schott, U
    Ziemer, G
    Claussen, CD
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1998, 7 (04) : 321 - 324
  • [25] A rare complication of the use of the 6 French suture-mediated closure device
    Agnoletti, G
    Le Bidois, J
    Jan, D
    CARDIOLOGY IN THE YOUNG, 2005, 15 (03) : 324 - 325
  • [26] Ultrasonographic assessment and clinical outcomes after deployment of a suture-mediated femoral vascular closure device
    Papoutsis, Dimitrios
    Mourouzis, Konstantinos
    Bozini, Nikoleta
    Aznaouridis, Konstantinos
    Oikonomou, Evangelos
    Chatzimichael, Katerina
    Brountzos, Elias
    Vavuranakis, Manolis
    Tsioufis, Costas
    Lekakis, John
    Siasos, Gerasimos
    Tousoulis, Dimitris
    CARDIOVASCULAR JOURNAL OF AFRICA, 2023,
  • [27] Management of arterial puncture site after catheterization procedures: Evaluating a suture-mediated closure device
    Gerckens, U
    Cattelaens, N
    Lampe, EG
    Grube, E
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (12): : 1658 - 1663
  • [28] Nonocclusive "Island" of Stenosis after Suture-mediated Arteriotomy Closure
    Wickman, Christopher
    Resnick, Scott A.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (12) : 1642 - 1644
  • [29] Initial experience using Prostar(TM): A new device for percutaneous suture-mediated closure of arterial puncture sites
    Carere, RG
    Webb, JG
    Ahmed, T
    Dodek, AA
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 37 (04): : 367 - 372
  • [30] Percutaneous transluminal angioplasty of suture-mediated closure device-related femoral artery stenosis or occlusive disease
    Kim, Y-J
    Yoon, H-K
    Ko, G-Y
    Shin, J-H
    Sung, K-B
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (978): : 486 - 490