Atrial function analysis after percutaneous umbrella device and suture-mediated patent fossa ovalis closure

被引:4
|
作者
Tarsia, Carmela [1 ]
Gaspardone, Carlo [2 ]
Sgueglia, Gregory A. [1 ]
De Santis, Antonella [1 ]
D'ascoli, Emanuela [1 ]
Piccioni, Fabiana [1 ]
Iamele, Maria [1 ]
Posteraro, Giuseppe A. [1 ]
Cinque, Alessandra [1 ]
Gaspardone, Achille [1 ,3 ]
机构
[1] St Eugenio Hosp, Unit Cardiol, Rome, Italy
[2] Univ Vita Salute San Raffaele, Milan, Italy
[3] St Eugenio Hosp, Unit Cardiol, Piazzale Umanesimo 10, I-00144 Rome, Italy
关键词
Atrial function; Cardiology; Septal occluder device; STRAIN-RATE; FORAMEN; ECHOCARDIOGRAPHY; OUTCOMES; THERAPY;
D O I
10.23736/S2724-5683.21.05710-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Atrial fibrillation is an undesirable event following percutaneous patent fossa ovalis (PFO) closure with metallic occluders, suggesting that implanting a rigid closure device could alter atrial function. Suture-mediated PFO closure is a new technique, achieving closure of the PFO by means of a simple suture. Aim of this study was to evaluate left atrial function after closure of PFO by direct suture and traditional occluders.METHODS: We studied 40 age and sex homogeneous patients, 20 undergoing PFO closure by device (OCL) and 20 by suturing (NS). Twenty healthy sex-age matched subjects made up the control group (CT). Left atrial function was evaluated by using volumetric and speckle-tracking analysis assessing the following parameters: total emptying fraction (EF), Expansion Index (EI), active emptying fraction (AEF), strain values of the reservoir (r-ED), conduit (cd-ED) and contraction phase (ct-ED).RESULTS: Compared to CT and NS, OCL patients had significantly worst indices of left atrial reservoir function (EF P=0.001, EI P=0.003, r-ED P<0.001), conduit function (cd-ED P=0.018) and contraction function (AEF P=0.010; ct-ED P<0.001). No significant differences were observed in left atrial function indices between CT and NS patients. CONCLUSIONS: Suture-mediated PFO closure does not alter left atrial function. Conversely, metallic occluder is as-sociated with worse left atrium function. This detrimental effect on atrial function could favor the development of atrial arrhythmias.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 50 条
  • [41] Assessment of Left Atrial Function after Percutaneous Closure of Patent Foramen Ovale
    Vavuranakis, Manolis
    Kavouras, Charalampos
    Vlasseros, Ioannis
    Aggeli, Constantina
    Felekos, Ioannis
    Vrachatis, Dimitrios A.
    Stefanadis, Christodoulos
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (07): : 765 - 771
  • [42] Percutaneous Suture-mediated Closure Versus Surgical Arteriotomy in Endovascular Aortic Aneurysm Repair
    Etezadi, Vahid
    Katzen, Barry T.
    Naiem, Amer
    Johar, Amardeep
    Wong, Scott
    Fuller, Joseph
    Benenati, James F.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (02) : 142 - 147
  • [43] Commentary on 'A Randomized Controlled Trial of the Fascia Suture Technique Compared with a Suture-mediated Closure Device for Femoral Arterial Closure After Endovascular Aortic Repair'
    Wanhainen, A.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 49 (02) : 174 - 174
  • [44] Safety and efficacy of the perclose suture-mediated closure device after diagnostic and interventional catheterizations in a large consecutive population
    Kahn, ZM
    Kumar, M
    Hollander, G
    Frankel, R
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (01) : 8 - 13
  • [45] Percutaneous suture-mediated closure of femoral access sites deployed through the procedure sheath: Initial clinical experience with a novel vascular closure device
    Eggebrecht, H
    Naber, C
    Woertgen, U
    Ringe, S
    Konorza, TFM
    Schmermund, A
    von Birgelen, C
    Haude, M
    Kroeger, K
    Erbel, R
    Baumgart, D
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (03) : 313 - 321
  • [46] Antegrade Femoral Puncture Using a Suture-Mediated Closure Device in Infrainguinal Endovascular Interventions
    Mastrorilli, Davide
    Forcella, Edoardo
    Miccoli, Tommaso
    De Massari, Chiara
    Garriboli, Luca
    ANNALS OF VASCULAR SURGERY, 2025, 112 : 246 - 252
  • [47] Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair
    Chan, Gabriel
    Quek, Lawrence Hwee Han
    Tan, Glenn Leong Wei
    Pua, Uei
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (07) : 1036 - 1039
  • [48] Comparison of costs and safety of a suture-mediated closure device with conventional manual compression after coronary artery interventions
    Rickli, H
    Unterweger, M
    Sütsch, G
    Brunner-La Rocca, HP
    Sagmeister, M
    Ammann, P
    Amann, FW
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (03) : 297 - 302
  • [49] Angiographic follow-up after suture-mediated femoral artery closure
    Brown, DB
    Crawford, ST
    Norton, PL
    Hovsepian, DM
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (07) : 677 - 680
  • [50] Successful Angioplasty of a Superficial Femoral Artery Stenosis Caused by a Suture-Mediated Closure Device
    Joseph J. Gemmete
    Narasimham Dasika
    Andrew R. Forauer
    Kyung Cho
    David M. Williams
    CardioVascular and Interventional Radiology, 2003, 26 : 410 - 412