Electroless Deposition of Gold on a Glassy Carbon Electrode (GCE) Surface for Selective Detection of Hydrogen Peroxide

被引:2
|
作者
Imran Hossain, Mohammad [1 ]
Dutta, Anim [1 ]
Ahmed, Jahir [2 ,3 ]
Faisal, Mohd [2 ,3 ]
Algethami, Jari S. [2 ,3 ]
Harraz, Farid A. [2 ,4 ]
Hasnat, Mohammad A. [1 ]
机构
[1] Shahjalal Univ Sci & Technol, Sch Phys Sci, Dept Chem, Electrochem & Catalysis Res Lab ECRL, Sylhet 3114, Bangladesh
[2] Najran Univ, Promising Ctr Sensors & Elect Devices PCSED, Adv Mat & Nanores Ctr, Najran 11001, Saudi Arabia
[3] Najran Univ, Fac Sci & Arts, Dept Chem, Najran 11001, Saudi Arabia
[4] Najran Univ, Fac Sci & Arts Sharurah, Dept Chem, Sharurah 68342, Saudi Arabia
来源
CHEMISTRYSELECT | 2024年 / 9卷 / 01期
关键词
Chemisorption; Electroless deposition; Glassy carbon electrode; Hydrogen peroxide sensor; Kinetics; COLLOIDAL GOLD; ELECTROCHEMICAL DETECTION; AMPEROMETRIC SENSOR; NANOPARTICLES; GRAPHENE; REDUCTION; IMMOBILIZATION; SUBMONOLAYER; HYDROQUINONE; DEGRADATION;
D O I
10.1002/slct.202301638
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electroless deposition technique was employed to coat the surface of a glassy carbon electrode (GCE) with nanoparticles of gold (AuNPs). Afterward, sulfur (S) components were immobilized onto this AuNPs/GC electrode via an in-situ chemisorption approach that considerably enhanced the catalytic activity, conductivity, and persistent durability of the electrode. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS) were used to characterize the modified electrode surface. The experimental results indicated that the S-AuNPs/GC electrode exhibits outstanding catalytic activity for the selective detection of H2O2 (HP). SWV measurements showed that the electrochemical sensor has a wide linear range of 10 to 2500 mu M and a heightened sensitivity of 50.08 mu A mM-1 cm-2. The proposed HP sensor demonstrated adequate repeatability and durability, as well as interference-free quantitative analysis capability. Conventional GCE and Au electrodes are ineffective in carrying out hydrogen peroxide (HP) reduction reactions. Whereas Au NPs modified GCE break down HP to O2 causing O2 interference in the subsequent HP sensing. In such a case, a sulfur adlayer can seal the Au facets responsible for O2 reduction allowing the unblocking of the active sites of Au at -0.93 V enabling a two-electron transfer HP reduction reaction.image
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Fabrication of Prussian Blue/Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode for Electrochemical Detection of Hydrogen Peroxide
    Farah, Abdullahi Mohamed
    Shooto, Ntaote David
    Thema, Force Tefo
    Modise, Johannes Sekomeng
    Dikio, Ezekiel Dixon
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (05): : 4302 - 4313
  • [42] Glassy carbon electrode modified with gold nanoparticles and hemoglobin in a chitosan matrix for improved pH-switchable sensing of hydrogen peroxide
    Liu, Yang
    Shi, Liang
    Gong, Jin
    Fang, Yu-Ting
    Bao, Ning
    Gu, Hai-Ying
    Zeng, Jiang
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2461 - 2468
  • [44] Flow Injection Non-Enzymatic Amperometric Detection of Hydrogen Peroxide Based on a Glassy Carbon Electrode Modified with Silver Particles on Glassy Carbon Spherical Powder
    Sirisaeng, Thanaporn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Limbut, Warakorn
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (03) : B74 - B82
  • [45] Glassy carbon electrode modified with gold nanoparticles and hemoglobin in a chitosan matrix for improved pH-switchable sensing of hydrogen peroxide
    Yang Liu
    Liang Shi
    Jin Gong
    Yu-Ting Fang
    Ning Bao
    Hai-Ying Gu
    Jiang Zeng
    Microchimica Acta, 2015, 182 : 2461 - 2468
  • [47] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Wang, Ai-Jun
    Zhang, Pei-Pei
    Li, Yong-Fang
    Feng, Jiu-Ju
    Dong, Wen-Ju
    Liu, Xue-Yan
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 31 - 37
  • [48] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320
  • [49] A New Hydrogen Peroxide Biosensor Based on Hrp/Ag Nanowires/Glassy Carbon Electrode
    Zhang, Min
    Cheng, Faliang
    Cai, Zhiquan
    Chen, Meiqiong
    MECHANICAL AND AEROSPACE ENGINEERING, PTS 1-7, 2012, 110-116 : 577 - 584
  • [50] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Ai-Jun Wang
    Pei-Pei Zhang
    Yong-Fang Li
    Jiu-Ju Feng
    Wen-Ju Dong
    Xue-Yan Liu
    Microchimica Acta, 2011, 175 : 31 - 37