Glassy carbon electrode modified with gold nanoparticles and hemoglobin in a chitosan matrix for improved pH-switchable sensing of hydrogen peroxide

被引:0
|
作者
Yang Liu
Liang Shi
Jin Gong
Yu-Ting Fang
Ning Bao
Hai-Ying Gu
Jiang Zeng
机构
[1] Nantong University,Institute of Analytical Chemistry for Life Science, School of Public Health
来源
Microchimica Acta | 2015年 / 182卷
关键词
Hemoglobin; Gold nanoparticles; Chitosan; Electrochemistry;
D O I
暂无
中图分类号
学科分类号
摘要
Hemoglobin (Hb) has been demonstrated to endow electrochemical sensors with pH-switchable response because of the presence of carboxyl and amino groups. Hb was deposited in a chitosan matrix on a glassy carbon electrode (GCE) that was previously coated with clustered gold nanoparticles (Au-NPs) by electrodeposition. The switching behavior is active (“on”) to the negatively charged probe [Fe(CN)63−] at pH 4.0, but inactive (“off”) to the probe at pH 8.0. This switch is fully reversible by simply changing the pH value of the solution and can be applied for pH-controlled reversible electrochemical reduction of H2O2 catalyzed by Hb. The modified electrode was tested for its response to the different electroactive probes. The response to these species strongly depends on pH which was cycled between 4 and 8. The effect is also attributed to the presence of pH dependent charges on the surface of the electrode which resulted in either electrostatic attraction or repulsion of the electroactive probes. The presence of Hb, in turn, enhances the pH-controllable response, and the electrodeposited Au-NPs improve the capability of switching. This study reveals the potential of protein based pH-switchable materials and also provides a simple and effective strategy for fabrication of switchable chemical sensors as exemplified in a pH-controllable electrode for hydrogen peroxide.
引用
收藏
页码:2461 / 2468
页数:7
相关论文
共 50 条
  • [1] Glassy carbon electrode modified with gold nanoparticles and hemoglobin in a chitosan matrix for improved pH-switchable sensing of hydrogen peroxide
    Liu, Yang
    Shi, Liang
    Gong, Jin
    Fang, Yu-Ting
    Bao, Ning
    Gu, Hai-Ying
    Zeng, Jiang
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2461 - 2468
  • [2] A modified glassy carbon electrode for hydrogen peroxide sensing
    Zheng, Cai-yun
    Chen, Shui-hong
    Shang, Yong-jia
    Li, Mao-guo
    ANNALI DI CHIMICA, 2007, 97 (11-12) : 1227 - 1235
  • [3] A glassy carbon electrode modified with SnO2 nanofibers, polyaniline and hemoglobin for improved amperometric sensing of hydrogen peroxide
    A. K. M. Kafi
    Qamar Wali
    Rajan Jose
    Tapan Kumar Biswas
    Mashitah M. Yusoff
    Microchimica Acta, 2017, 184 : 4443 - 4450
  • [4] A glassy carbon electrode modified with SnO2 nanofibers, polyaniline and hemoglobin for improved amperometric sensing of hydrogen peroxide
    Kafi, A. K. M.
    Wali, Qamar
    Jose, Rajan
    Biswas, Tapan Kumar
    Yusoff, Mashitah M.
    MICROCHIMICA ACTA, 2017, 184 (11) : 4443 - 4450
  • [5] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320
  • [6] Amperometric biosensor for nitrite and hydrogen peroxide based on hemoglobin immobilized on gold nanoparticles/polythionine/platinum nanoparticles modified glassy carbon electrode
    Zhang, Yu
    Yuan, Ruo
    Chai, Yaqin
    Wang, Jinfen
    Zhong, Huaan
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (04) : 570 - 574
  • [7] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Qingxia Wang
    Haili Zhang
    Yiwei Wu
    Aimin Yu
    Microchimica Acta, 2012, 176 : 279 - 285
  • [8] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [9] Hydrogen peroxide sensor based on hemoglobin immobilized on glassy carbon electrode with SiO2 nanoparticles/chitosan film as immobilization matrix
    Zhang, H.
    Zou, X.
    Han, D.
    ANALYTICAL LETTERS, 2007, 40 (04) : 661 - 676
  • [10] Immobilization of Hemoglobin on the Gold Colloid Modified Pretreated Glassy Carbon Electrode for Preparing a Novel Hydrogen Peroxide Biosensor
    Liu, Yang
    Jiang, Qi-Yu
    Lu, Shuang-Yun
    Zhang, Ye
    Gu, Hai-Ying
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2009, 152 (03) : 418 - 427