Electroless Deposition of Gold on a Glassy Carbon Electrode (GCE) Surface for Selective Detection of Hydrogen Peroxide

被引:2
|
作者
Imran Hossain, Mohammad [1 ]
Dutta, Anim [1 ]
Ahmed, Jahir [2 ,3 ]
Faisal, Mohd [2 ,3 ]
Algethami, Jari S. [2 ,3 ]
Harraz, Farid A. [2 ,4 ]
Hasnat, Mohammad A. [1 ]
机构
[1] Shahjalal Univ Sci & Technol, Sch Phys Sci, Dept Chem, Electrochem & Catalysis Res Lab ECRL, Sylhet 3114, Bangladesh
[2] Najran Univ, Promising Ctr Sensors & Elect Devices PCSED, Adv Mat & Nanores Ctr, Najran 11001, Saudi Arabia
[3] Najran Univ, Fac Sci & Arts, Dept Chem, Najran 11001, Saudi Arabia
[4] Najran Univ, Fac Sci & Arts Sharurah, Dept Chem, Sharurah 68342, Saudi Arabia
来源
CHEMISTRYSELECT | 2024年 / 9卷 / 01期
关键词
Chemisorption; Electroless deposition; Glassy carbon electrode; Hydrogen peroxide sensor; Kinetics; COLLOIDAL GOLD; ELECTROCHEMICAL DETECTION; AMPEROMETRIC SENSOR; NANOPARTICLES; GRAPHENE; REDUCTION; IMMOBILIZATION; SUBMONOLAYER; HYDROQUINONE; DEGRADATION;
D O I
10.1002/slct.202301638
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electroless deposition technique was employed to coat the surface of a glassy carbon electrode (GCE) with nanoparticles of gold (AuNPs). Afterward, sulfur (S) components were immobilized onto this AuNPs/GC electrode via an in-situ chemisorption approach that considerably enhanced the catalytic activity, conductivity, and persistent durability of the electrode. Scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS) were used to characterize the modified electrode surface. The experimental results indicated that the S-AuNPs/GC electrode exhibits outstanding catalytic activity for the selective detection of H2O2 (HP). SWV measurements showed that the electrochemical sensor has a wide linear range of 10 to 2500 mu M and a heightened sensitivity of 50.08 mu A mM-1 cm-2. The proposed HP sensor demonstrated adequate repeatability and durability, as well as interference-free quantitative analysis capability. Conventional GCE and Au electrodes are ineffective in carrying out hydrogen peroxide (HP) reduction reactions. Whereas Au NPs modified GCE break down HP to O2 causing O2 interference in the subsequent HP sensing. In such a case, a sulfur adlayer can seal the Au facets responsible for O2 reduction allowing the unblocking of the active sites of Au at -0.93 V enabling a two-electron transfer HP reduction reaction.image
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Gold Nanoframe Array Electrode for Straightforward Detection of Hydrogen Peroxide
    Purwidyantri, Agnes
    Tian, Ya-Chung
    Saputra, Gardin Muhammad Andika
    Prabowo, Briliant Adhi
    Liu, Hui-Ling
    Yang, Chia-Ming
    Lai, Chao-Sung
    CHEMOSENSORS, 2021, 9 (02) : 1 - 13
  • [32] Electroless deposition of gold nanoparticles on a glassy carbon surface to attain methylene blue degradation via oxygen reduction reactions
    Islam, Md Tarikul
    Hasan, Md Mahmudul
    Shabik, Md Fazle
    Islam, Fahadul
    Nagao, Yuki
    Hasnat, Mohammad A.
    ELECTROCHIMICA ACTA, 2020, 360
  • [33] A ternary nanocomposite electrode of polyoxometalate/carbon nanotubes/gold nanoparticles for electrochemical detection of hydrogen peroxide
    Guo, Shuyue
    Xu, Lin
    Xu, Bingbing
    Sun, Zhixia
    Wang, Lihao
    ANALYST, 2015, 140 (03) : 820 - 826
  • [34] Voltammetric study of saffron in blood mediated by modified glassy carbon electrode (GCE) with carbon nanotube (CNT/GCE)
    Radhi, Muhammed Mizher
    Khalaf, Maysara Samer
    Ali, Zainab Oun
    Al-Dabbagh, Thamir Aboud
    EPITOANYAG-JOURNAL OF SILICATE BASED AND COMPOSITE MATERIALS, 2018, 70 (03): : 78 - 81
  • [35] Mechanism of hydrogen peroxide oxidation reaction at a glassy carbon electrode in alkaline solution
    Westbroek, P
    Temmerman, E
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 482 (01): : 40 - 47
  • [36] Electrochemical determination of hydrogen peroxide at a glassy carbon electrode modified with palladium nanoparticles
    Kitte, Shimeles Addisu
    Assresahegn, Birhanu Desalegn
    Soreta, Tesfaye Refera
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (05) : 701 - 711
  • [37] Investigation on the electrochemical behaviors of phenol oxidation on GCE (glassy carbon electrode)
    Wang, Yan
    Zuo, Shaoqing
    Zhu, Huaigong
    ADVANCES IN MATERIALS AND MATERIALS PROCESSING, PTS 1-3, 2013, 652-654 : 1684 - +
  • [38] Selective Electrochemical Determination of L-Cysteine by a Cobalt Carbon Nanotube (CNT)-Modified Glassy Carbon Electrode (GCE)
    Kivrak, Hilal
    Selcuk, Kadir
    Caglar, Aykut
    Aktas, Nahit
    ANALYTICAL LETTERS, 2024, 57 (17) : 2798 - 2812
  • [39] One-step voltammetric deposition of L-proline assisted silver nanoparticles modified glassy carbon electrode for electrochemical detection of hydrogen peroxide
    Zhao, Fengming
    Zhou, Menglei
    Wang, Lingqiao
    Huang, Zhangkao
    Chu, Youqun
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 833 : 205 - 212
  • [40] Electrochemical Deposition of Gold Nanoparticles on a Glassy Carbon Electrode Modified with Sulfanilic Acid
    Lin, Tai-Hsuan
    Hung, Wei-Hsiu
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (02) : D45 - D50