Mapping of Thoracodorsal Artery Perforators: Accuracy of Thermography and Handheld Doppler

被引:1
|
作者
Illg, Claudius [1 ]
Heinzel, Johannes C. [1 ]
Denzinger, Markus [2 ]
Schaefer, Ruth C. [1 ]
Daigeler, Adrien [1 ]
Krauss, Sabrina [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Hand Plast Reconstruct & Burn Surg, BG Unfallklin Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
[2] Univ Med Ctr Regensburg, Dept Pediat Surg, Klin St Hedwig, Regensburg, Germany
关键词
thoracodorsal artery flap; latissimus dorsi musculocutaneous flap; thermography; DIRT; color duplex ultrasound; handheld Doppler; DORSI MUSCULOCUTANEOUS FLAPS; RECONSTRUCTION; RELIABILITY; ULTRASOUND; EXPERIENCE; ANATOMY; MUSCLE;
D O I
10.1055/s-0044-1779733
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The versatile musculocutaneous latissimus dorsi flap and the thoracodorsal artery (TDA) perforator flap have developed into indispensable approaches in reconstructive surgery. While the anatomy of the TDA is consistent, the skin perforators vary in location and course. Dynamic infrared thermography (DIRT) recently gained popularity for perforator identification; however, its use and accuracy in thoracodorsal artery perforator (TDAP) mapping is yet to be determined. Methods TDAPs were visualized in 50 cases by DIRT. Based on the thermographic hotspots, the corresponding perforators were then identified by color duplex ultrasound (CDU) and handheld Doppler in a blinded fashion by two separate examiners. Results The midpoint of all perforator fascia passages was localized 99.7 mm caudal and 13.5 mm medial of the posterior axillary fold. The positive predictive value of perforator identification by dynamic infrared thermography was 86.5% and the correlating perforator fascia passage was 9.9 +/- 5.8 mm from the hotspot midpoint, with a maximum of 29 mm. The positive predictive value of perforator identification by handheld Doppler was 95% and the signal was 7.2 +/- 5.1 mm from the perforator fascia passage. Conclusion DIRT precisely localizes TDAPs. The fusion with CDU combines both modalities' advantages. The combination with handheld Doppler is a fast way of perforator imaging, decreasing the handheld Dopplers' high false positive rate.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 50 条
  • [41] Accuracy of color-Doppler in the quantification of proximal vertebral artery stenoses
    de Bray, JM
    Pasco, A
    Tranquart, F
    Papon, X
    Alecu, C
    Giraudeau, B
    Dubas, F
    Emile, J
    CEREBROVASCULAR DISEASES, 2001, 11 (04) : 335 - 340
  • [42] Diagnostic accuracy of uterine artery and spiral artery Doppler for evaluation of endometrial pathology in postmenopausal bleeding
    Nasheeha, Noorul
    Poomalar, G. K.
    JOURNAL OF GYNECOLOGY OBSTETRICS AND HUMAN REPRODUCTION, 2021, 50 (10)
  • [43] Boomerang-shaped Lateral-to-back Flap Utilizing Multiple Thoracodorsal Artery Perforators around the Lateral Border of Latissimus Dorsi Muscle for Reconstruction of Large Circular Defect
    Kagaya, Yu
    Arikawa, Masaki
    Sekiyama, Takuya
    Akazawa, Satoshi
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2020, 8 (02)
  • [44] Accuracy of infrared thermography for perforator mapping: A systematic review and meta-analysis of diagnostic studies
    Berner, Juan Enrique
    Pereira, Nicolas
    Troisi, Luigi
    Will, Patrick
    Nanchahal, Jagdeep
    Jain, Abhilash
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2021, 74 (06): : 1173 - 1179
  • [45] Accuracy of gray scale and color Doppler sonographic mapping in diagnosis of pneumonia in adult
    Elkholy, Maha M.
    Mohammad, Hala A.
    Osman, Nasr M.
    Ibraheem, Bahaa
    Emam, Rash
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2016, 65 (02): : 491 - 498
  • [46] ASSESSMENT OF THE ACCURACY OF COLOR DOPPLER FLOW MAPPING BY DIGITAL IMAGE-ANALYSIS
    WALKER, PG
    KIM, YH
    MURALIDHARAN, E
    MIYAJIMA, Y
    DELATORE, J
    YOGANATHAN, AP
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1994, 11 (01): : 11 - 28
  • [47] Preoperative vascular mapping with multislice CT of deep inferior epigastric artery perforators in planning breast reconstruction after mastectomy
    Pellegrin, A.
    Stocca, T.
    Belgrano, M.
    Bertolotto, M.
    Pozzi-Mucelli, F.
    Arnez, Z. Marij
    Cova, M. A.
    RADIOLOGIA MEDICA, 2013, 118 (05): : 732 - 743
  • [48] Accuracy of color Doppler versus angiography in the quantification of proximal vertebral artery stenoses
    de Bray, JM
    Pasco, A
    Papon, X
    Cosmin, A
    Tranquart, F
    Dubas, F
    Emile, J
    STROKE, 2000, 31 (01) : 329 - 329
  • [49] The accuracy of transcranial Doppler in the diagnosis of stenosis or occlusion of the terminal internal carotid artery
    Navarro, JC
    Mikulik, R
    Garami, Z
    Alexandrov, AV
    JOURNAL OF NEUROIMAGING, 2004, 14 (04) : 314 - 318
  • [50] Diagnostic accuracy of Doppler ultrasonography for assessment of internal thoracic artery graft patency
    Joob, Beuy
    Wiwanitkit, Viroj
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2014, 14 (08): : 754 - 756