Mapping of Thoracodorsal Artery Perforators: Accuracy of Thermography and Handheld Doppler

被引:1
|
作者
Illg, Claudius [1 ]
Heinzel, Johannes C. [1 ]
Denzinger, Markus [2 ]
Schaefer, Ruth C. [1 ]
Daigeler, Adrien [1 ]
Krauss, Sabrina [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Hand Plast Reconstruct & Burn Surg, BG Unfallklin Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
[2] Univ Med Ctr Regensburg, Dept Pediat Surg, Klin St Hedwig, Regensburg, Germany
关键词
thoracodorsal artery flap; latissimus dorsi musculocutaneous flap; thermography; DIRT; color duplex ultrasound; handheld Doppler; DORSI MUSCULOCUTANEOUS FLAPS; RECONSTRUCTION; RELIABILITY; ULTRASOUND; EXPERIENCE; ANATOMY; MUSCLE;
D O I
10.1055/s-0044-1779733
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The versatile musculocutaneous latissimus dorsi flap and the thoracodorsal artery (TDA) perforator flap have developed into indispensable approaches in reconstructive surgery. While the anatomy of the TDA is consistent, the skin perforators vary in location and course. Dynamic infrared thermography (DIRT) recently gained popularity for perforator identification; however, its use and accuracy in thoracodorsal artery perforator (TDAP) mapping is yet to be determined. Methods TDAPs were visualized in 50 cases by DIRT. Based on the thermographic hotspots, the corresponding perforators were then identified by color duplex ultrasound (CDU) and handheld Doppler in a blinded fashion by two separate examiners. Results The midpoint of all perforator fascia passages was localized 99.7 mm caudal and 13.5 mm medial of the posterior axillary fold. The positive predictive value of perforator identification by dynamic infrared thermography was 86.5% and the correlating perforator fascia passage was 9.9 +/- 5.8 mm from the hotspot midpoint, with a maximum of 29 mm. The positive predictive value of perforator identification by handheld Doppler was 95% and the signal was 7.2 +/- 5.1 mm from the perforator fascia passage. Conclusion DIRT precisely localizes TDAPs. The fusion with CDU combines both modalities' advantages. The combination with handheld Doppler is a fast way of perforator imaging, decreasing the handheld Dopplers' high false positive rate.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 50 条
  • [21] Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators
    Kim, Jong Gyu
    Lee, Soo Hyang
    ARCHIVES OF PLASTIC SURGERY-APS, 2012, 39 (04): : 354 - 359
  • [22] Treatment of Hidradenitis Suppurativa with Extensive Resection of the Lesion and Coverage with Perforator Flaps of the Lateral Thoracic Wall (Lateral Thoracic Artery, Thoracodorsal Artery Perforators)
    Rodriguez, Jorge M.
    Rodriguez, Felipe
    Rivera, Daniel
    Naranjo, Karol
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2019, 7 (02)
  • [23] Preoperative perforator mapping of anterolateral thigh perforators via Projected Augmented Reality and Dynamic Infrared Thermography
    Meier, Eva L.
    de Jong, Tim
    Ulrich, Dietmar J. O.
    Hummelink, Stefan
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2025, 100 : 60 - 66
  • [24] Diagnostic accuracy of new handheld echocardiography with doppler and harmonic Imaging properties
    Borges, AC
    Knebel, F
    Walde, T
    Sanad, W
    Baumann, G
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (03) : 234 - 238
  • [25] In-Vivo Quantitative Mapping of the Perforasomes of Deep Inferior Epigastric Artery Perforators
    Leung, Rachael
    Chae, Michael P.
    Tobin, Vicky
    Hunter-Smith, David J.
    Rozen, Warren M.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2018, 6 (10)
  • [26] Handheld Doppler Detection and Light Illumination for Vascular Mapping in Nasal Reconstruction
    Zhang, Xulong
    Song, Zhen
    Xu, Yihao
    Zheng, Ruobing
    Guo, Junsheng
    Tian, Le
    Wang, Huan
    You, Jianjun
    Fan, Fei
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (01) : 59 - 62
  • [27] Use of a handheld Doppler to measure brachial and femoral artery occlusion pressure
    Vehrs, Pat R.
    Richards, Shay
    Blazzard, Chase
    Hart, Hannah
    Kasper, Nicole
    Lacey, Ryan
    Lopez, Daniela
    Baker, Luke
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [28] Examine the Diagnostic Accuracy of Handheld Doppler Ultrasound for Diagnosing Peripheral Vascular Disease
    Ali, Sana Sharafat
    Asghar, Syed Tanseer
    Khan, Javed Iqbal
    Khan, Shahzad
    Kashif, Muhammad
    Khan, Zardad
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (04): : 1342 - 1344
  • [29] Anatomical study and colour Doppler assessment of the skin perforators of the anterior tibial artery and possible clinical applications
    Panagiotopoulos, K.
    Soucacos, P. N.
    Korres, D. S.
    Petrocheilou, G.
    Kalogeropoulos, A.
    Panagiotopoulos, E.
    Zoubos, A. B.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2009, 62 (11): : 1524 - 1529
  • [30] COMPARISON OF DOPPLER SONOGRAPHY AND PLATE THERMOGRAPHY FOR DETECTION OF CAROTID-ARTERY STENOSIS
    HOFFERBERTH, B
    GOTTSCHALDT, M
    DYKAN, S
    STROKE, 1980, 11 (01) : 27 - 30