Mapping of Thoracodorsal Artery Perforators: Accuracy of Thermography and Handheld Doppler

被引:1
|
作者
Illg, Claudius [1 ]
Heinzel, Johannes C. [1 ]
Denzinger, Markus [2 ]
Schaefer, Ruth C. [1 ]
Daigeler, Adrien [1 ]
Krauss, Sabrina [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Hand Plast Reconstruct & Burn Surg, BG Unfallklin Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
[2] Univ Med Ctr Regensburg, Dept Pediat Surg, Klin St Hedwig, Regensburg, Germany
关键词
thoracodorsal artery flap; latissimus dorsi musculocutaneous flap; thermography; DIRT; color duplex ultrasound; handheld Doppler; DORSI MUSCULOCUTANEOUS FLAPS; RECONSTRUCTION; RELIABILITY; ULTRASOUND; EXPERIENCE; ANATOMY; MUSCLE;
D O I
10.1055/s-0044-1779733
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The versatile musculocutaneous latissimus dorsi flap and the thoracodorsal artery (TDA) perforator flap have developed into indispensable approaches in reconstructive surgery. While the anatomy of the TDA is consistent, the skin perforators vary in location and course. Dynamic infrared thermography (DIRT) recently gained popularity for perforator identification; however, its use and accuracy in thoracodorsal artery perforator (TDAP) mapping is yet to be determined. Methods TDAPs were visualized in 50 cases by DIRT. Based on the thermographic hotspots, the corresponding perforators were then identified by color duplex ultrasound (CDU) and handheld Doppler in a blinded fashion by two separate examiners. Results The midpoint of all perforator fascia passages was localized 99.7 mm caudal and 13.5 mm medial of the posterior axillary fold. The positive predictive value of perforator identification by dynamic infrared thermography was 86.5% and the correlating perforator fascia passage was 9.9 +/- 5.8 mm from the hotspot midpoint, with a maximum of 29 mm. The positive predictive value of perforator identification by handheld Doppler was 95% and the signal was 7.2 +/- 5.1 mm from the perforator fascia passage. Conclusion DIRT precisely localizes TDAPs. The fusion with CDU combines both modalities' advantages. The combination with handheld Doppler is a fast way of perforator imaging, decreasing the handheld Dopplers' high false positive rate.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 50 条
  • [31] 2-DIMENSIONAL COLOR DOPPLER IMAGING FOR PRECISION PREOPERATIVE MAPPING AND SIZE DETERMINATION OF TRAM FLAP PERFORATORS
    CHANG, BW
    LUETHKE, R
    BERG, WA
    HAMPER, UM
    MANSON, PN
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 93 (01) : 197 - 200
  • [32] Handheld Doppler Localization of the Angular Artery to Reduce Intravascular Injection in Tear Trough Rejuvenation
    Noell, Claire M.
    Weiss, Robert A.
    DERMATOLOGIC SURGERY, 2021, 47 (08) : 1171 - 1173
  • [33] Diagnostic accuracy and efficacy of color Doppler mapping for tubal patency
    Demir, Berfu
    Kocak, Muberra
    Beydilli, Gulay
    Kaplan, Metin
    Gelisen, Orhan
    Haberal, Ali
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2011, 37 (07) : 782 - 786
  • [34] Thoracodorsal artery perforator (TDAP) flap in immediate breast reconstruction and the role of preoperative mapping: A clinical experience
    Lopez Ojeda A.B.
    Lopez C.C.
    Rodrigues T.A.G.
    Vidal J.M.
    Suñe C.H.
    Bermejo Segu J.O.
    Narvaez J.A.
    Serra Payro J.M.
    Palacin Porte J.A.
    Viñals Viñals J.M.
    European Journal of Plastic Surgery, 2013, 36 (3) : 165 - 170
  • [35] Scrotal Thermography and Doppler Ultrasonography of the Testicular Artery of Buffaloes Subjected to Environmental Heat Stress
    Ramires Neto, Carlos
    de Resende, Helene Lacerda
    Monteiro, Gabriel A.
    Zorzetto, Mariana F.
    Sancler da Silva, Yame F. R.
    Oba, Eunice
    BUFFALO BULLETIN, 2013, 32 : 1145 - 1145
  • [36] The accuracy of transvaginal ultrasound and uterine artery Doppler in the prediction of adenomyosis
    ElKattan, Eman
    Omran, Eman
    Al Inany, Hisham
    MIDDLE EAST FERTILITY SOCIETY JOURNAL, 2010, 15 (02) : 73 - 78
  • [37] The accuracy of transcranial Doppler in the diagnosis of middle cerebral artery stenosis
    Navarro, Jose C.
    Lao, Annabelle Y.
    Sharma, Vijay K.
    Tsivgoulis, Georgios
    Alexandrov, Andrei V.
    CEREBROVASCULAR DISEASES, 2007, 23 (5-6) : 325 - 330
  • [38] Improving the Accuracy of Easily Accessible 5-MHz Handheld Doppler Examination in Perforator Flap Planning
    Hocaoglu, Emre
    Elbey, Huseyin
    Salmaslioglu, Artur
    Erer, Metin
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (01) : 130E - 132E
  • [39] ACCURACY OF SPATIAL JET MAPPING WITH A NEW COLOR CODED FLOW MAPPING DOPPLER TECHNIQUE - COMPARISON OF ULTRASOUND DOPPLER WITH LASER DOPPLER IN AN INVITRO MODEL OF VALVE STENOSIS
    YOGANATHAN, AP
    SAHN, DJ
    VALDESCRUZ, L
    SHERMAN, F
    SWENSSON, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 453 - 453
  • [40] ACCURACY OF ECHO-DOPPLER FLOWMETRY FOR RENAL-ARTERY STENOSIS
    ANTONICA, G
    SABBA, C
    BERARDI, E
    BUONAMICO, P
    PAOLO, C
    VULPIS, V
    ETTORRE, G
    PIRRELLI, A
    ALBANO, O
    JOURNAL OF HYPERTENSION, 1991, 9 : S240 - S241