Mapping of Thoracodorsal Artery Perforators: Accuracy of Thermography and Handheld Doppler

被引:1
|
作者
Illg, Claudius [1 ]
Heinzel, Johannes C. [1 ]
Denzinger, Markus [2 ]
Schaefer, Ruth C. [1 ]
Daigeler, Adrien [1 ]
Krauss, Sabrina [1 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Hand Plast Reconstruct & Burn Surg, BG Unfallklin Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
[2] Univ Med Ctr Regensburg, Dept Pediat Surg, Klin St Hedwig, Regensburg, Germany
关键词
thoracodorsal artery flap; latissimus dorsi musculocutaneous flap; thermography; DIRT; color duplex ultrasound; handheld Doppler; DORSI MUSCULOCUTANEOUS FLAPS; RECONSTRUCTION; RELIABILITY; ULTRASOUND; EXPERIENCE; ANATOMY; MUSCLE;
D O I
10.1055/s-0044-1779733
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The versatile musculocutaneous latissimus dorsi flap and the thoracodorsal artery (TDA) perforator flap have developed into indispensable approaches in reconstructive surgery. While the anatomy of the TDA is consistent, the skin perforators vary in location and course. Dynamic infrared thermography (DIRT) recently gained popularity for perforator identification; however, its use and accuracy in thoracodorsal artery perforator (TDAP) mapping is yet to be determined. Methods TDAPs were visualized in 50 cases by DIRT. Based on the thermographic hotspots, the corresponding perforators were then identified by color duplex ultrasound (CDU) and handheld Doppler in a blinded fashion by two separate examiners. Results The midpoint of all perforator fascia passages was localized 99.7 mm caudal and 13.5 mm medial of the posterior axillary fold. The positive predictive value of perforator identification by dynamic infrared thermography was 86.5% and the correlating perforator fascia passage was 9.9 +/- 5.8 mm from the hotspot midpoint, with a maximum of 29 mm. The positive predictive value of perforator identification by handheld Doppler was 95% and the signal was 7.2 +/- 5.1 mm from the perforator fascia passage. Conclusion DIRT precisely localizes TDAPs. The fusion with CDU combines both modalities' advantages. The combination with handheld Doppler is a fast way of perforator imaging, decreasing the handheld Dopplers' high false positive rate.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 50 条
  • [1] Preoperative color Doppler ultrasonographic examination in the planning of thoracodorsal artery perforator flap with capillary perforators
    Tashiro, Kensuke
    Yamashita, Shuji
    Araki, Jun
    Narushima, Mitsunaga
    Iida, Takuya
    Koshima, Isao
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2016, 69 (03): : 346 - 350
  • [2] Different types of suprafascial courses in thoracodorsal artery skin perforators
    Lin, Cheng-Ta
    Huang, Jer-Shyung
    Hsu, Kuei-Chang
    Yang, Kuo-Chung
    Chen, Jin-Shyr
    Chen, Lee-Wei
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 121 (03) : 840 - 848
  • [3] Using dynamic infrared thermography to optimize color Doppler ultrasound mapping of cutaneous perforators.
    Muntean, Maximilian Vlad
    Strilciuc, Stefan
    Ardelean, Filip
    Pestean, Cosmin
    Lacatus, Radu
    Badea, Alexandru Florin
    Georgescu, Alexandru
    MEDICAL ULTRASONOGRAPHY, 2015, 17 (04) : 503 - 508
  • [4] Reliability of anatomical landmarks for skin perforators of the thoracodorsal artery perforator flap
    Lin, Cheng-Ta
    Huang, Jer-Shyung
    Yang, Kuo-Chung
    Hsu, Kuei-Chang
    Chen, Jin-Shyr
    Chen, Lee-Wei
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 118 (06) : 1376 - 1386
  • [5] Three-dimensional visualization of thoracodorsal artery perforators using photoacoustic imaging
    Shimizu, Hanako
    Saito, Susumu
    Yoshikawa, Aya
    Sekiguchi, Hiroyuki
    Tsuge, Itaru
    Morimoto, Naoki
    Toi, Masakazu
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (09): : 3166 - 3173
  • [6] Reliability of anatomical landmarks for skin perforators of the thoracodorsal artery perforator flap - Discussion
    Disa, Joseph J.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 118 (06) : 1387 - 1387
  • [7] Evaluation of Diagnostic Accuracy Using Preoperative Handheld Doppler in Identifying the Cutaneous Perforators in the Anterolateral Thigh Flap: A Systematic Review
    Cheng, Hsu-Tang
    Lin, Fu-Yu
    Chang, Sophia Chia-Ning
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 129 (04) : 769E - 770E
  • [8] New thoracodorsal artery perforator (TAPcp) flap with capillary perforators for reconstruction of upper limb
    Koshima, Isao
    Narushima, Mitsunaga
    Mihara, Makoto
    Iida, Takuya
    Gonda, Koichi
    Uchida, Gentaro
    Nakagawa, Masahiro
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2010, 63 (01): : 140 - 145
  • [9] Efficacy of the handheld Doppler in preoperative identification of the cutaneous perforators in the anterolateral thigh flap
    Yu, Peirong
    Youssef, Adel
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 118 (04) : 928 - 933
  • [10] Efficacy of the handheld Doppler in preoperative identification of the cutaneous perforators in the anterolateral thigh flap - Discussion
    Levin, L. Scott
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 118 (04) : 934 - 935