Mechanical, natural and hybrid ventilation systems in different building types: Energy and indoor air quality analysis

被引:20
|
作者
Tognon, Giacomo [1 ]
Marigo, Marco [1 ]
De Carli, Michele [1 ]
Zarrella, Angelo [1 ]
机构
[1] Univ Padua, Dept Ind Engn, Appl Phys Sect, Via Venezia 1, I-35131 Padua, Italy
来源
关键词
Air conditioning systems; Hybrid ventilation; Natural ventilation; Infection risk; Building simulations; FLOW;
D O I
10.1016/j.jobe.2023.107060
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ventilation is fundamental for providing good Indoor Air Quality in buildings. Nevertheless, it involves considerable energy consumption. In this paper, a co-simulation approach was applied to two case studies, a residential and an educational building, to evaluate different control strategies for hybrid ventilation systems in terms of annual energy demand and risk mitigation. The sim-ulations were performed using TRNSYS and CONTAM and successively applying the Wells-Riley model to estimate the airborne infection risk. The analysis is performed for three climates, Venice, Rome and Helsinki. Results for the apartment show that different control strategies do not lead to significant variations in the overall heating demand for a given climate. In contrast, increasing natural ventilation hours during the cooling season produces savings in both sensible (up to 31% in Venice) and latent demand (up to 30% in Rome). Fan absorption in the heating season is reduced by 40% and 86% in Rome for the flat and classroom, respectively and by 84% in Venice for the apartment in the cooling season. Moreover, a control strategy enhancing natural venti-lation is promising in reducing the infection risk. Therefore, if well-regulated through a suitable control strategy, the hybrid ventilation system seems promising in maintaining healthy indoor environments while reducing energy consumption.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] INDOOR AIR-QUALITY IN 3 SMALL HOUSING FLATS WITH DIFFERENT VENTILATION SYSTEMS
    REPONEN, T
    KOKOTTI, H
    SAVOLAINEN, T
    RAUNEMAA, T
    JOURNAL OF AEROSOL SCIENCE, 1987, 18 (06) : 701 - 704
  • [22] The effect of natural ventilation strategy on indoor air quality in schools
    Stabile, Luca
    Dell'Isola, Marco
    Russi, Aldo
    Massimo, Angelamaria
    Buonanno, Giorgio
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 595 : 894 - 902
  • [23] Energy implications of meeting indoor air quality and thermal comfort standards in Mediterranean schools using natural and mechanical ventilation strategies
    Maiques, M.
    Tarragona, J.
    Gangolells, M.
    Casals, M.
    ENERGY AND BUILDINGS, 2025, 328
  • [24] Ventilation performance and indoor air quality in workstations under different supply air systems: A numerical approach
    Jiang, Z
    Haghighat, F
    Chen, Q
    INDOOR AND BUILT ENVIRONMENT, 1997, 6 (03) : 160 - 167
  • [25] Impact of different mechanical ventilation strategies for night purging on indoor air quality in public buildings
    Lestinen, Sami
    Kilpelainen, Simo
    Kosonen, Risto
    Jokisalo, Juha
    COLD CLIMATE HVAC & ENERGY 2021, 2021, 246
  • [26] Indoor air quality varies with ventilation types and working areas in hospitals
    Jung, Chien-Cheng
    Wu, Pei-Chih
    Tseng, Chao-Heng
    Su, Huey-Jen
    BUILDING AND ENVIRONMENT, 2015, 85 : 190 - 195
  • [27] Measuring and analysis of indoor air quality of building
    Li, DY
    Deng, QQ
    Pan, SY
    Hao, XJ
    Shi, YZ
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 627 - 633
  • [28] Energy efficiency and indoor air quality of seminar rooms in older buildings with and without mechanical ventilation
    Maas, Stefan
    Antunes, Joel Da Cruz
    Steffgen, Georges
    BAUPHYSIK, 2019, 41 (05) : 243 - 251
  • [29] The Relationship between Mechanical Ventilation, Indoor Air Quality Classes, and Energy Classes in a Romanian Context
    Vasile, Vasilica
    Iordache, Vlad
    Radu, Valentin Mihai
    Dragomir, Claudiu-Sorin
    ATMOSPHERE, 2024, 15 (04)
  • [30] THE EFFECTS OF REDUCED VENTILATION ON INDOOR AIR-QUALITY IN AN OFFICE BUILDING
    TURIEL, I
    HOLLOWELL, CD
    MIKSCH, RR
    RUDY, JV
    YOUNG, RA
    COYE, MJ
    ATMOSPHERIC ENVIRONMENT, 1983, 17 (01) : 51 - 64