The effect of natural ventilation strategy on indoor air quality in schools

被引:112
|
作者
Stabile, Luca [1 ]
Dell'Isola, Marco [1 ]
Russi, Aldo [1 ]
Massimo, Angelamaria [1 ]
Buonanno, Giorgio [2 ,3 ]
机构
[1] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, Via Di Biasio 43, I-03043 Cassino, FR, Italy
[2] Univ Parthenope, Dept Engn, Naples, Italy
[3] Queensland Univ Technol, Brisbane, Qld, Australia
关键词
Schools; Exposure; Particles; Airing strategy; CO2; Ultrafine particles; Ventilation; LUNG-CANCER RISK; ULTRAFINE PARTICLES; PARTICULATE MATTER; AIRBORNE PARTICLES; ITALIAN CLASSROOMS; MEDITERRANEAN BUILDINGS; THERMAL CONDITIONS; EXPOSURE; POLLUTANTS; RADON;
D O I
10.1016/j.scitotenv.2017.03.048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to reduce children's exposure to pollutants in classrooms a proper ventilation strategy need to be adopted. Such strategy is even more important in naturally ventilated schools where the air exchange rate is only based on the manual airing of classrooms. The present work aimed to evaluate the effect of the manual airing strategy on indoor air quality in Italian classrooms. For this aim, schools located in the Central Italy were investigated. Indoor air quality was studied in terms of CO2, particle number and PM concentrations and compared to corresponding outdoor levels. In particular two experimental analyses were performed: i) a comparison between heating and non heating season in different schools; ii) an evaluation of the effect of scheduled airing periods on the dilution of indoor-generated pollutants and the penetration of outdoor-generated ones. In particular, different airing procedures, i.e. different window opening periods (5 to 20 min per hour) were imposed and controlled through contacts installed on classroom windows and doors. Results revealed that the airing strategy differently affect the several pollutants detected in indoors depending on their size, origin and dynamics. Longer airing periods may result in reduced indoor CO2 concentrations and, similarly, other gaseous indoor-generated pollutants. Simultaneously, higher ultrafine particle (and other vehicular-related pollutants) levels in indoors were measured due to infiltration from outdoors. Finally, a negligible effect of the manual airing on PM levels in classroom was detected. Therefore, a simultaneous reduction in concentration levels for all the pollutant metrics in classrooms cannot be obtained just relying upon air permeability of the building envelope and manual airing of the classrooms. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:894 / 902
页数:9
相关论文
共 50 条
  • [1] The Effects of Ventilation on Indoor Air Quality in Schools
    Zhong, Lexuan
    [J]. 2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [2] Effect of ventilation on indoor air quality
    Chen Jin-hua
    Duan Sheng-hui
    Zheng Ping
    Zhao Wen-jiang
    Zi Li-mei
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 48 - 52
  • [3] From spontaneous to strategic natural window ventilation: Improving indoor air quality in Swiss schools
    Vassella, Claudia C.
    Koch, Jeremy
    Henzi, Alexander
    Jordan, Alexander
    Waeber, Roger
    Iannaccone, Reto
    Charriere, Roland
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2021, 234
  • [4] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Shin, HS
    Lee, JK
    Ahn, YC
    Yeo, CS
    Byun, SH
    Lee, JK
    Kang, TW
    Lee, KG
    Park, HS
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2005, 19 (04) : 1001 - 1005
  • [5] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Shin, HS
    Ahn, YC
    Lee, JK
    Kang, TW
    Lee, KG
    Park, HS
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2762 - 2766
  • [6] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Hee-Soo Shin
    Jai-Kwon Lee
    Young-Chull Ahn
    Chang-Shin Yeo
    Sang-Hyun Byun
    Jae-Keun Lee
    Tae-Wook Kang
    Kam-Gyu Lee
    Hyo-Soon Park
    [J]. Journal of Mechanical Science and Technology, 2005, 19 : 1001 - 1005
  • [7] Effect of quality and maintenance of the ventilation to the indoor air quality
    Niskanen, J
    Valkeapää, A
    Anttonen, H
    [J]. PROGRESS IN MODERN VENTILATION, VOL 2, PROCEEDINGS, 2000, : 168 - 171
  • [8] The effect of post-COVID-19 ventilation measures on indoor air quality in primary schools
    Eichholtz, Piet
    Kok, Nils
    Sun, Xudong
    [J]. PNAS NEXUS, 2023, 3 (01):
  • [9] Effect of natural ventilation on indoor air quality and thermal comfort in dormitory during winter
    Lei, Zhangping
    Liu, Chuanping
    Wang, Li
    Li, Na
    [J]. BUILDING AND ENVIRONMENT, 2017, 125 : 240 - 247
  • [10] Ventilation and Indoor Air Quality
    Kumar, Ashok
    Moreno-Rangel, Alejandro
    Khan, M. Amirul, I
    Piasecki, Michal
    [J]. ATMOSPHERE, 2022, 13 (10)