Automatic Calibration of a Device for Blood Pressure Waveform Measurement

被引:0
|
作者
Siemasz, Rafal [1 ]
Tomczuk, Krzysztof [1 ]
Malecha, Ziemowit [1 ]
Felisiak, Piotr Andrzej [1 ]
Weiser, Artur [2 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Mech & Power Engn, PL-50370 Wroclaw, Poland
[2] Wroclaw Med Univ, Dept Neurosurg, PL-50425 Wroclaw, Poland
关键词
blood pressure measurement; pneumatic sensor; blood pressure waveform; sensor calibration; ARTERIAL TONOMETRY; EUROPEAN-SOCIETY; VALIDATION;
D O I
10.3390/s23187985
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article presents a prototype of a new, non-invasive, cuffless, self-calibrating blood pressure measuring device equipped with a pneumatic pressure sensor. The developed sensor has a double function: it measures the waveform of blood pressure and calibrates the device. The device was used to conduct proof-of-concept measurements on 10 volunteers. The main novelty of the device is the pneumatic pressure sensor, which works on the principle of a pneumatic nozzle flapper amplifier with negative feedback. The developed device does not require a cuff and can be used on arteries where cuff placement would be impossible (e.g., on the carotid artery). The obtained results showed that the systolic and diastolic pressure measurement errors of the proposed device did not exceed & PLUSMN;6.6% and & PLUSMN;8.1%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] VALIDATION OF A SELF BLOOD-PRESSURE MEASUREMENT DEVICE
    FOUQUERAY, B
    JULIEN, J
    PAGNY, JY
    JEUNEMAITRE, X
    SASSANO, P
    BATTAGLIA, C
    PLOUIN, PF
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1988, 10 (05) : 907 - 907
  • [42] DEVELOPMENT OF A PULSE OXIMETER AND BLOOD PRESSURE MEASUREMENT DEVICE
    Fe, Ana
    Sousa, Joana
    Gamboa, Hugo
    BIODEVICES: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2012, : 201 - 206
  • [43] A Systematic Review on Blood Pressure Measurement Technologies and Calibration Techniques
    Penumerthy, Suman
    Min, Seung Nam
    Subramaniyam, Murali
    ADVANCES IN HUMAN FACTORS AND ERGONOMICS IN HEALTHCARE AND MEDICAL DEVICES (AHFE 2021), 2021, 263 : 245 - 252
  • [44] Instruments and Methods for Calibration of Oscillometric Blood Pressure Measurement Devices
    Balestrieri, Eulalia
    Rapuano, Sergio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (09) : 2391 - 2404
  • [45] Automated Pressure Calibration of Blood Pressure Measuring Device Calibrator To Realize Its Traceability
    Turk, Ahmet
    Hamarat, Abdullah
    2019 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2019,
  • [46] EVALUATION OF A NEW MONITORING DEVICE FOR ARTERIAL BLOOD-PRESSURE AND HEART-RATE MEASUREMENT BY AUTOMATIC SPHYGMOMANOMETRY
    CHASTONAY, P
    MOREL, D
    FORSTER, A
    SUTER, PM
    ANASTHESIE INTENSIVTHERAPIE NOTFALLMEDIZIN, 1982, 17 (06): : 348 - 350
  • [47] Measurement home blood pressure: Validation of the device automatic artsana CSI 610 in agreement with international protocol ESH
    Pini, C.
    Gerosa, R.
    Pastori, M.
    Baccheschi, J.
    Omboni, S.
    Parati, G.
    JOURNAL OF HYPERTENSION, 2007, 25 : S38 - S39
  • [48] CLINICAL-EVALUATIONS OF A NEW AUTOMATIC ELECTRONIC DEVICE FOR THE MEASUREMENT OF THE BLOOD-PRESSURE (SPHYGMODIGITAL-4000)
    MULLER, PO
    BARISWYL, C
    REGAMEY, C
    WEIDMANN, P
    SCHWEIZERISCHE RUNDSCHAU FUR MEDIZIN PRAXIS, 1983, 72 (23): : 804 - 812
  • [49] Automatic calibration of pressure transducers
    不详
    CHEMICAL ENGINEERING & TECHNOLOGY, 1999, 22 (09) : 728 - 728
  • [50] ESTIMATES OF BLOOD-PRESSURE VARIABILITY IN ADOLESCENTS USING AN AUTOMATIC BLOOD-PRESSURE MEASURING DEVICE
    LOMBARDI, DA
    GILLMAN, MW
    ELLISON, RC
    HOSMER, DW
    PULEO, EM
    JOURNAL OF HUMAN HYPERTENSION, 1994, 8 (06) : 441 - 443