Automatic Calibration of a Device for Blood Pressure Waveform Measurement

被引:0
|
作者
Siemasz, Rafal [1 ]
Tomczuk, Krzysztof [1 ]
Malecha, Ziemowit [1 ]
Felisiak, Piotr Andrzej [1 ]
Weiser, Artur [2 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Mech & Power Engn, PL-50370 Wroclaw, Poland
[2] Wroclaw Med Univ, Dept Neurosurg, PL-50425 Wroclaw, Poland
关键词
blood pressure measurement; pneumatic sensor; blood pressure waveform; sensor calibration; ARTERIAL TONOMETRY; EUROPEAN-SOCIETY; VALIDATION;
D O I
10.3390/s23187985
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article presents a prototype of a new, non-invasive, cuffless, self-calibrating blood pressure measuring device equipped with a pneumatic pressure sensor. The developed sensor has a double function: it measures the waveform of blood pressure and calibrates the device. The device was used to conduct proof-of-concept measurements on 10 volunteers. The main novelty of the device is the pneumatic pressure sensor, which works on the principle of a pneumatic nozzle flapper amplifier with negative feedback. The developed device does not require a cuff and can be used on arteries where cuff placement would be impossible (e.g., on the carotid artery). The obtained results showed that the systolic and diastolic pressure measurement errors of the proposed device did not exceed & PLUSMN;6.6% and & PLUSMN;8.1%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] THE MEASUREMENT OF AMBULATORY BLOOD-PRESSURE BY AN AUTOMATIC METHOD
    MALLION, JM
    DEGAUDEMARIS, R
    DEBRU, JL
    DOYON, B
    PERDRIX, A
    MORIN, B
    CAU, G
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1980, 73 : 95 - 101
  • [32] AUTOMATIC MEASUREMENT OF BLOOD PRESSURE WITHOUT ARTERIAL PUNCTURE
    WOLFF, HS
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1969, 62 (10): : 1019 - &
  • [33] Brachial artery waveforms for automatic blood pressure measurement
    Al-Jumaily, A. M.
    Lan, H.
    Stergiopulos, N.
    JOURNAL OF BIOMECHANICS, 2013, 46 (03) : 506 - 510
  • [34] EVALUATION OF AN AUTOMATIC BLOOD-PRESSURE DEVICE FOR USE IN BLOOD-PRESSURE SCREENING PROGRAMS
    DORING, A
    FILIPIAK, B
    METHODS OF INFORMATION IN MEDICINE, 1984, 23 (02) : 75 - 81
  • [35] What is the Awareness Level of the Hypertensive Elderly People on the Blood Pressure Measurement Follow-up and Device Calibration?
    Genc, Fatma
    Yigitbas, Cagla
    BEZMIALEM SCIENCE, 2022, 10 (03): : 353 - 360
  • [36] Development of an Automatic Blood Aspiration Device for Periodic Measurement of Blood Glucose Level
    Lim, Fang Ming
    Putra, Andi S.
    Yeoh, Jo Ern
    Winata, Laird A.
    Tan, Kok Kiong
    Chew, Sophia T. H.
    Ti, Lian Kah
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (02):
  • [37] AUTOMATIC DEVICE FOR MEASURING BLOOD-PRESSURE - ARTERIOSONDE 1217
    LAULHERE, L
    DOYON, B
    DEBRU, JL
    MORIN, B
    MALLION, JM
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1979, 72 : 120 - 125
  • [38] Clinical validation of an automatic device measuring blood pressure in the fingers
    Arosio, E
    Zannoni, M
    PANMINERVA MEDICA, 1999, 41 (02) : 143 - 148
  • [39] A device for calibration of semiautomatic and automatic apparatuses for measuring arterial pressure and pulse rate
    Gogin V.A.
    Vargin A.A.
    Karataev R.N.
    Biomedical Engineering, 2002, 36 (3) : 181 - 182
  • [40] Repeated office blood pressure measurement by automated device to evaluate blood pressure control
    Crippa, G
    Sverzellati, E
    Venturi, C
    Antoniotti, P
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 46A - 46A