Automatic Calibration of a Device for Blood Pressure Waveform Measurement

被引:0
|
作者
Siemasz, Rafal [1 ]
Tomczuk, Krzysztof [1 ]
Malecha, Ziemowit [1 ]
Felisiak, Piotr Andrzej [1 ]
Weiser, Artur [2 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Mech & Power Engn, PL-50370 Wroclaw, Poland
[2] Wroclaw Med Univ, Dept Neurosurg, PL-50425 Wroclaw, Poland
关键词
blood pressure measurement; pneumatic sensor; blood pressure waveform; sensor calibration; ARTERIAL TONOMETRY; EUROPEAN-SOCIETY; VALIDATION;
D O I
10.3390/s23187985
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article presents a prototype of a new, non-invasive, cuffless, self-calibrating blood pressure measuring device equipped with a pneumatic pressure sensor. The developed sensor has a double function: it measures the waveform of blood pressure and calibrates the device. The device was used to conduct proof-of-concept measurements on 10 volunteers. The main novelty of the device is the pneumatic pressure sensor, which works on the principle of a pneumatic nozzle flapper amplifier with negative feedback. The developed device does not require a cuff and can be used on arteries where cuff placement would be impossible (e.g., on the carotid artery). The obtained results showed that the systolic and diastolic pressure measurement errors of the proposed device did not exceed & PLUSMN;6.6% and & PLUSMN;8.1%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] VALIDATION OF A SELF BLOOD PRESSURE MEASUREMENT DEVICE
    FOUQUERAY, B
    JULIEN, J
    PAGNY, JY
    JEUNEMAITRE, X
    SASSANO, P
    BATTAGLIA, C
    PLOUIN, PF
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1988, 81 : 231 - 234
  • [22] Monitoring of the central blood pressure waveform via a conformal ultrasonic device
    Wang, Chonghe
    Li, Xiaoshi
    Hu, Hongjie
    Zhang, Lin
    Huang, Zhenlong
    Lin, Muyang
    Zhang, Zhuorui
    Yin, Zhenan
    Huang, Brady
    Gong, Hua
    Bhaskaran, Shubha
    Gu, Yue
    Makihata, Mitsutoshi
    Guo, Yuxuan
    Lei, Yusheng
    Chen, Yimu
    Wang, Chunfeng
    Li, Yang
    Zhang, Tianjiao
    Chen, Zeyu
    Pisano, Albert P.
    Zhang, Liangfang
    Zhou, Qifa
    Xu, Sheng
    NATURE BIOMEDICAL ENGINEERING, 2018, 2 (09): : 687 - 695
  • [23] Monitoring of the central blood pressure waveform via a conformal ultrasonic device
    Chonghe Wang
    Xiaoshi Li
    Hongjie Hu
    Lin Zhang
    Zhenlong Huang
    Muyang Lin
    Zhuorui Zhang
    Zhenan Yin
    Brady Huang
    Hua Gong
    Shubha Bhaskaran
    Yue Gu
    Mitsutoshi Makihata
    Yuxuan Guo
    Yusheng Lei
    Yimu Chen
    Chunfeng Wang
    Yang Li
    Tianjiao Zhang
    Zeyu Chen
    Albert P. Pisano
    Liangfang Zhang
    Qifa Zhou
    Sheng Xu
    Nature Biomedical Engineering, 2018, 2 : 687 - 695
  • [24] Accuracy of blood pressure measurement: sphygmomanometer calibration and beyond
    Parati, Gianfranco
    Faini, Andrea
    Castiglioni, Paolo
    JOURNAL OF HYPERTENSION, 2006, 24 (10) : 1915 - 1918
  • [25] An Automated Calibration System for Blood Pressure Measurement Traceability
    B. A. Rodrigues Filho
    R. F. Farias
    W. E. dos Anjos
    MAPAN, 2020, 35 : 43 - 51
  • [26] An Automated Calibration System for Blood Pressure Measurement Traceability
    Rodrigues Filho, B. A.
    Farias, R. F.
    dos Anjos, W. E.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2020, 35 (01): : 43 - 51
  • [27] Validation of semi-automatic device UA-704 for self-measurement of blood pressure
    Kobalava, ZD
    Kotovskaya, YV
    Rodionov, E
    BLOOD PRESSURE MONITORING, 2005, 10 (04) : 223 - 225
  • [28] Validation of semi-automatic device UA-704 for self-measurement of blood pressure
    Kobalava, ZD
    Kotovskaya, YV
    Rodionov, EV
    AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (05) : 36A - 36A
  • [29] ARE AUTOMATIC DEVICES SUITABLE FOR BLOOD-PRESSURE MEASUREMENT
    ADORJANI, C
    SIEGENTHALER, W
    VETTER, W
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1979, 109 (33) : 1225 - 1230
  • [30] PETECHIAL RASHES AND AUTOMATIC BLOOD-PRESSURE MEASUREMENT
    NICHOLLS, BJ
    RYAN, DW
    ANAESTHESIA, 1986, 41 (01) : 88 - 88