Effect of novel prefabricated auxiliary devices attaching to scan bodies on the accuracy of intraoral scanning of complete-arch with multiple implants: An in-vitro study

被引:6
|
作者
Wu, Hio Kuan [1 ]
Wang, Jing [2 ]
Chen, Guanhui [3 ]
Huang, Xiaoqiong [1 ]
Deng, Feilong [1 ,4 ]
Li, Yiming [1 ,4 ]
机构
[1] Sun Yat sen Univ, Hosp Stomatol, Guanghua Sch Stomatol, Guangdong Prov Key Lab Stomatol, Guangzhou 510055, Peoples R China
[2] YangHe Dent Clin, Guangzhou 510055, Peoples R China
[3] Sun Yat sen Univ, Affiliated Hosp 7, Dept Stomatol, Shenzhen 518107, Guangdong, Peoples R China
[4] Sun Yat Sen Univ, Hosp Stomatol, Guanghua Sch Stomatol, Guangdong Prov Key Lab Stomatol, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Accuracy; Dental implant; Digital impression; Intraoral scanner; Scan body; Edentulous; PROSTHESES; PRECISION; JAW;
D O I
10.1016/j.jdent.2023.104702
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To examine the effect of novel prefabricated auxiliary devices with different geometric features called Scan Body Clasp (SBC) at different levels on the accuracy of intraoral scanning of complete-arch with multiple implants.Methods: An edentulous maxilla 4-implant model and SBCs with different geometric features (flat or curved) were fabricated by a 3D printer (AccuFab-C1s, 3DShining, Hangzhou, China). Test scans were performed using an intraoral scanner (Aoralscan 3, 3DShining, Hangzhou, China) software version 1.0.0.3104 under different sce-narios: group A (CO), without any SBCs; group B&C (LC&HC), with curved SBCs adjacent to and away from the mucosa; group D&E (LF&HF), with flat SBCs adjacent to and away from the mucosa. 20 scans were done for each group (CO, LC, HC, LF and HF). Reference Scans were obtained by digitizing the model in group A using a dental laboratory scanner (D2000, 3Shape, Copenhagen, Denmark). The related files were imported into inspection software for trueness and precision assessment. Statistical analysis was performed with One-way ANOVA, Independent-Sample T test for trueness values. Kruskal-Wallis test and Mann-Whitney test were used to assess the precision values. The level of significance was set at alpha=0.05.Results: Groups with SBCs demonstrated trueness enhancement, among which LF revealed the best trueness. Significant differences were also found between LF and HC (p < .01), LF and HF (p < .001), LC and HF (p < .01). LF and HF showed precision enhancement. The best precision was LF, which was found to be more precise than LC (p < .001) and HC (p < .001). HF was more precise than LC (p < .001) and HC (p < .001).Conclusions: Attaching the scan bodies with SBCs at different levels significantly influenced the scanning accu-racy. The SBCs near the mucosa result in superior trueness, while the flat morphology benefits the precision. Clinical significance: The results demonstrated the feasibility of the SBCs in enhancing intraoral complete-arch implant scanning accuracy. Among the configurations tested in the present study, low-level and flat surfaces of the artificial landmarks may be the potential pivotal elements to optimizing long-span scanning accuracy.
引用
收藏
页数:8
相关论文
共 46 条
  • [21] Improved scanning accuracy with newly designed scan bodies: An in vitro study comparing digital versus conventional impression techniques for complete-arch implant rehabilitation
    Huang, Ruoxuan
    Liu, Yuanxiang
    Huang, Baoxin
    Zhang, Chaobiao
    Chen, Zhuofan
    Li, Zhipeng
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (07) : 625 - 633
  • [22] Influence of scanning protocol on the accuracy of complete-arch digital implant scans: An in vitro study
    Hamilton, Adam
    Negreiros, William Matthew
    Jain, Shruti
    Finkelman, Matthew
    Gallucci, German O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) : 641 - 651
  • [23] Error propagation from intraoral scanning to additive manufacturing of complete-arch dentate models: An in vitro study
    Auskalnis, Liudas
    Akulauskas, Mykolas
    Jegelevicius, Darius
    Simonaitis, Tomas
    Rutkunas, Vygandas
    [J]. JOURNAL OF DENTISTRY, 2022, 121
  • [24] Comparative Analysis of Intraoral Scanner Accuracy in a Six-Implant Complete-Arch Model: An In Vitro Study
    Ferrini, Francesco
    Mazzoleni, Federica
    Barbini, Matteo
    Coppo, Carlotta
    Di Domenico, Giovanna Laura
    Gherlone, Enrico Felice
    [J]. PROSTHESIS, 2024, 6 (02): : 401 - 412
  • [25] Accuracy of Implant Level Intraoral Scanning and Photogrammetry Impression Techniques in a Complete Arch with Angled and Parallel Implants: An In Vitro Study
    Tohme, Hani
    Lawand, Ghida
    Eid, Rita
    Ahmed, Khaled E.
    Salameh, Ziad
    Makzoume, Joseph
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [26] Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods
    Mai, Hai Yen
    Mai, Hang-Nga
    Lee, Cheong-Hee
    Lee, Kyu-Bok
    Kim, So-yeun
    Lee, Jae-Mok
    Lee, Keun-Woo
    Lee, Du-Hyeong
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (02): : 88 - 95
  • [27] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117
  • [28] Evaluating the influence of palate scanning on the accuracy of complete-arch digital impressions-An in vitro study
    Schmalzl, Judit
    Keskeny, Gyorgy Arpad
    Hermann, Peter
    Pal, Adrienn
    Geczi, Zoltan
    Borbely, Judit
    Roth, Ivett
    [J]. JOURNAL OF DENTISTRY, 2024, 145
  • [29] Effect of intraoral scanner and fixed partial denture situation on the scan accuracy of multiple implants: An in vitro study
    Donmez, Mustafa Borga
    Mathey, Ayse
    Gaumann, Fabio
    Mathey, Amber
    Yilmaz, Burak
    Abou-Ayash, Samir
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (03) : 502 - 510
  • [30] Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study
    Cakmak, Gulce
    Yilmaz, Hakan
    Santos, Alejandro Trevino
    Kokat, Ali Murat
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 419 - 426