Effect of intraoral scanner and fixed partial denture situation on the scan accuracy of multiple implants: An in vitro study

被引:5
|
作者
Donmez, Mustafa Borga [1 ,2 ]
Mathey, Ayse [2 ]
Gaumann, Fabio [2 ]
Mathey, Amber [2 ]
Yilmaz, Burak [2 ,3 ,4 ]
Abou-Ayash, Samir [2 ]
机构
[1] Istinye Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[2] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[4] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
关键词
fixed partial denture; implant; intraoral scanner; precision; trueness; IMPRESSION TECHNIQUES;
D O I
10.1111/cid.13190
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundAccuracy of intraoral implant scans may be affected by the region of the implant and the type of the intraoral scanner (IOSs). However, there is limited knowledge on the scan accuracy of multiple implants placed for an implant-supported fixed partial denture (FPD) in different partially edentulous situations when digitized by using different IOSs. PurposeTo investigate the effect of IOS and FPD situation on the scan accuracy of two implants when partial-arch scans were performed. Materials and MethodsTissue level implants were placed in 3 maxillary models with implant spaces either at right first premolar and right first molar sites (Model 1, 3-unit FPD), at right canine and right first molar sites (Model 2, 4-unit FPD), or at lateral incisor sites (Model 3, 4-unit FPD). Reference standard tessellation language (STL) files of the models were generated by using an optical scanner (ATOS Capsule 200MV120). Two IOSs (CEREC Primescan [CP] and TRIOS 3 [TR]) were used to perform partial-arch scans (test-scans) of each model (n = 14), which were exported in STL format. A metrology-grade analysis software (GOM Inspect 2018) was used to superimpose test-scan STLs over the reference STL to calculate 3D distance, inter-implant distance, and angular (mesiodistal and buccopalatal) deviations. Trueness and precision analyses were performed by using bootstrap analysis of variance followed by Welch tests with Holm correction (alpha = 0.05). ResultsTrueness of the scans was affected by IOS and FPD situation when 3D distance deviations were considered, while inter-implant distance, mesiodistal angular, and buccopalatal angular deviations were only affected by the FPD situation (p < 0.001). Scan precision was affected by the interaction between the IOSs and the FPD situation when 3D distance and buccopalatal angular deviations were concerned, while IOSs and FPD situation were effective when all deviations were concerned (p <= 0.001). When 3D distance deviations were considered, CP scans had higher accuracy TR scans in Models 1 and 3 (p <= 0.002), and the Model 1 scans had the highest accuracy (p < 0.001). When inter-implant distance deviations were considered, Model 1 scans had the highest accuracy with CP and higher accuracy than Model 2 when TR was used (p <= 0.030). When mesiodistal angular deviations were considered, Model 1 scans had the highest accuracy (p <= 0.040). When buccopalatal angular deviations were considered, Model 1 scans had the highest accuracy among models when CP was used (p <= 0.020). ConclusionsPosterior 3-unit fixed partial denture implant scans, CP scans, and combination of these two factors had accuracy either similar to or better than their tested counterparts.
引用
收藏
页码:502 / 510
页数:9
相关论文
共 50 条
  • [1] Scan accuracy and time efficiency of different implantsupported fixed partial denture situations depending on the intraoral scanner and scanned area: An in vitro study
    Donmez, Mustafa Borga
    Mathey, Ayse
    Gaumann, Fabio
    Mathey, Amber
    Yilmaz, Burak
    Abou-Ayash, Samir
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1198 - 1207
  • [2] Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study
    Kernen, Florian
    Braendle, Dominik
    Wagendorf, Oliver
    Recca, Mario
    Mehrhof, Juergen
    Vach, Kirstin
    Nahles, Susanne
    Nelson, Katja
    Fluegge, Tabea
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (08) : 793 - 801
  • [3] Effect of Different Preparation Depths for an Inlay-Retained Fixed Partial Denture on the Accuracy of Different Intraoral Scanners: An In Vitro Study
    Khaled, Mohamed
    Sabet, Ahmed
    Ebeid, Kamal
    Salah, Tarek
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (07): : 601 - 605
  • [4] Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study
    Andriessen, Frank S.
    Riikens, David R.
    van der Meer, Wither J.
    Wismeijer, Daniell W.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03): : 186 - 194
  • [5] Comparative Accuracy of Intraoral and Extraoral Digital Workflows for Short Span Implant Supported Fixed Partial Denture Fabrication: An In Vitro Study
    Mansoor, Manawar Ahmad
    Sayed, Mohammed E.
    Abdul, Hina Naim
    Zaidan, Meshal Saleh
    Hakami, Thamer Mohammad
    Dighriri, Mohammed Abdullah
    Alqahtani, Saeed M.
    Alfaifi, Mohammed A.
    Altoman, Majed S.
    Jokhadar, Hossam F.
    AlResayes, Saad Saleh
    AlWadei, Mohammed H.
    Jundus, Asayil Ibrahim
    Komosany, Abeer Mohammed
    Al-Najjar, Hind Ziyad
    [J]. MEDICAL SCIENCE MONITOR, 2024, 30
  • [6] Comparative study of the accuracy of an implant intraoral scanner and that of a conventional intraoral scanner for-arch fixed dental
    Sallorenzo, Alessandro
    Gomez-Polo, Miguel
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1009 - 1016
  • [7] In vitro scan accuracy and time efficiency in various implant-supported fixed partial denture situations
    Abou-Ayash, Samir
    Mathey, Amber
    Gaeumann, Fabio
    Mathey, Ayse
    Donmez, Mustafa Borga
    Yilmaz, Burak
    [J]. JOURNAL OF DENTISTRY, 2022, 127
  • [8] In vitro scan accuracy and time efficiency in various implant-supported fixed partial denture situations
    Abou-Ayash, Samir
    Mathey, Amber
    Gaumann, Fabio
    Mathey, Ayse
    Donmez, Mustafa Borga
    Yilmaz, Burak
    [J]. JOURNAL OF DENTISTRY, 2022, 127
  • [9] Impact of Different Scan Bodies and Scan Strategies on the Accuracy of Digital Implant Impressions Assessed with an Intraoral Scanner: An In Vitro Study
    Motel, Constantin
    Kirchner, Elena
    Adler, Werner
    Wichmann, Manfred
    Matta, Ragai Edward
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (04): : 309 - 314
  • [10] Effect of Scanning Origin Location on Data Accuracy of Abutment Teeth Region in Digital Impression Acquired Using Intraoral Scanner for Removable Partial Denture: A Preliminary In Vitro Study
    Kim, Eung-Yeol
    Wada, Junichiro
    Sakamoto, Kazuki
    Ishioka, Yurika
    Arai, Yuki
    Murakami, Natsuko
    Yamazaki, Toshiki
    Hayama, Hironari
    Utsumi, Miona
    Inukai, Shusuke
    Wakabayashi, Noriyuki
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)