Analysis and optimization of injection characteristics and comprehensive performance of low GWP refrigerant HP-1 in high temperature heat pump systems

被引:3
|
作者
Wang, Yuehan [1 ]
Nan, Xiaohong [1 ]
Ouyang, Hongsheng [2 ]
Guo, Zhikai [2 ]
Hu, Bin [3 ]
Wang, R. Z.
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Zhejiang Res Inst Chem Ind Co Ltd, State Key Lab Fluorinated Greenhouse Gases Replace, Hangzhou 310023, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
关键词
HP-1; HTHP; Environmentally friendly refrigerant; Injection Characteristics; Performance analysis optimization; Decarbonization; VAPOR-INJECTION; SCROLL COMPRESSOR; 2-PHASE INJECTION; LIQUID INJECTION; R32; HCFO-1224YD(Z); INTERMEDIATE; ALTERNATIVES; R1233ZD(E); HFC-245FA;
D O I
10.1016/j.enbuild.2023.113799
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the context of low-GWP refrigerants becoming a research hotspot, the environmentally friendly refrigerant HP1 with independent intellectual property rights in China has demonstrated significant advantages in fields such as data centers and 5G base stations. However, there are few applied studies in the field of high-temperature heat pumps (HTHPs), therefore, in this study, HP-1 was utilized in HTHP system and this process was combined with the injection technology. It has been proven to be an effective approach for performance improvement. The injection characteristics of HP-1-based HTHP were analyzed and optimized with a focus on safety, stability, and efficient operation. The application advantages of HP-1 were compared and analyzed in terms of thermodynamic performance and Total Equivalent Warming Impact. The results indicated that there were three types of characteristic injection pressures based on system performance, corresponding to the maximum coefficient of performance (COP), the lowest electronic expansion valve inlet refrigerant temperature, and the lowest exhaust temperature of the compressor. Further, the corresponding control equations for injection pressure were obtained. Based on the safety injection pressure, the optimal COP under injection pressure could effectively improve the COP of the system by 2.1-5.2 %, and the exhaust temperature also increased by 6.1-10.1 %. When the temperature of the heat source was 50 degrees C and the target heating temperature was 120 degrees C, the heating capacity of HP-1 increased by 10.8 % compared with that of R245fa, the COP of the system increased by 2.7 %, and the volume heating capacity increased by 10.3 %. Moreover, the emission reduction effect of HP-1 was significant, and the carbon dioxide emissions were reduced by 15.4-39.1 %. The analysis shows that HP-1 exhibits better performance and environmental characteristics than HFC-245fa. This study is of guiding significance to improve the thermodynamic performance of HTHP, for the safe and efficient operation and energy saving and emission reduction in the industrial field.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] HIGH TEMPERATURE HEAT PUMP CASCADE SYSTEMS WITH WATER (R718) AS REFRIGERANT
    Hegner, R.
    Abu Khass, O.
    Moller, C.
    Stathopoulos, P.
    PROCEEDINGS OF ASME TURBO EXPO 2022: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2022, VOL 4, 2022,
  • [32] Theoretical analysis of the impacts of refrigerant leakage on the performance of a flash tank vapor injection heat pump
    Chen, Guangming
    Fang, Jiahao
    Li, Zetian
    Zhang, Shaozhi
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 147 : 10 - 19
  • [33] Performance simulation and exergy analysis of a hybrid source heat pump system with low GWP refrigerants
    Wu, Di
    Hu, Bin
    Wang, R. Z.
    RENEWABLE ENERGY, 2018, 116 : 775 - 785
  • [34] Characteristics of active refrigerant injection based on external heat source and its effects on performance of an air source heat pump
    Tu, Qiu
    Deng, Chenmian
    Gong, Xuemei
    Wei, LiLi
    Zhang, Lina
    Wu, Xiaogang
    Ji, Chenfan
    Boban, Luka
    Soldo, Vladimir
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 45
  • [35] Performance assessment of optimized heat pump water heaters using low-GWP refrigerants for high- and low-temperature applications
    Kim, Byeongsu
    Lee, DongChan
    Lee, Sang Hun
    Kim, Yongchan
    APPLIED THERMAL ENGINEERING, 2020, 181
  • [36] Significant thermal upgrade via cascade high temperature heat pump with low GWP working fluids
    Dong, Yixiu
    Yan, Hongzhi
    Wang, Ruzhu
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2024, 190
  • [37] Experimental study on the performance of a vapor injection high temperature heat pump
    He, Yongning
    Cao, Feng
    Jin, Lei
    Wang, Xiaolin
    Xing, Ziwen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 : 1 - 8
  • [38] Experimental performance of moderate and high temperature heat pump charged with refrigerant mixture BY-3
    Chen C.
    Zhang Y.
    Deng N.
    Ma H.
    Zhang Y.
    Ma L.
    Hu X.
    Transactions of Tianjin University, 2011, 17 (5) : 386 - 390
  • [39] Experimental Performance of Moderate and High Temperature Heat Pump Charged with Refrigerant Mixture BY-3
    陈成敏
    张于峰
    邓娜
    马洪亭
    张彦所
    马丽筠
    胡晓微
    Transactions of Tianjin University, 2011, 17 (05) : 386 - 390
  • [40] Experimental Performance of Moderate and High Temperature Heat Pump Charged with Refrigerant Mixture BY-3
    陈成敏
    张于峰
    邓娜
    马洪亭
    张彦所
    马丽筠
    胡晓微
    Transactions of Tianjin University, 2011, (05) : 386 - 390