Validation of a flow-cytometry-based red blood cell antigen phenotyping method

被引:6
|
作者
Liwski, Robert [1 ,2 ]
Clarke, Gwen [3 ,4 ]
Cheng, Calvino [1 ,2 ]
Abidi, Syed Sibte Raza [5 ]
Abidi, Samina Raza [6 ]
Quinn, Jason George [1 ,2 ,7 ]
机构
[1] Dalhousie Univ, Dept Pathol, Lab Med, Halifax, NS, Canada
[2] Nova Scotia Hlth Author, Cent Zone, Halifax, NS, Canada
[3] Univ Alberta, Dept Lab Med & Pathol, Edmonton, AB, Canada
[4] Canadian Blood Serv, Edmonton, AB, Canada
[5] Dalhousie Univ, Fac Comp Sci, Res Grp NICHE, Halifax, NS, Canada
[6] Dalhousie Univ, Fac Med, Dept Community Hlth & Epidemiol, Halifax, NS, Canada
[7] 5788 Univ Ave,Room 217, Halifax, NS B3H 1V8, Canada
关键词
antigen typing; flow cytometry; phenotyping; RBC phenotyping; transfusion; ALLOIMMUNIZATION; TRANSFUSIONS;
D O I
10.1111/vox.13401
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives Current manual and automated phenotyping methods are based on visual detection of the antigen-antibody interaction. This approach has several limitations including the use of large volumes of patient and reagent red blood cells (RBCs) and antisera to produce a visually detectable reaction. We sought to determine whether the flow cytometry could be developed and validated to perform RBC phenotyping to enable a high-throughput method of phenotyping using comparatively miniscule reagent volumes via fluorescence-based detection of antibody binding.Materials and Methods RBC phenotyping by flow cytometry was performed using monoclonal direct typing antisera (human IgM): anti-C, -E, -c, -e, -K, -Jk(a), -Jk(b) and indirect typing antisera (human IgG): anti-k, -Fy(a), -Fy(b), -S, -s that are commercially available and currently utilized in our blood transfusion services (BTS) for agglutination-based phenotyping assays.Results Seventy samples were tested using both flow-cytometry-based-phenotyping and a manual tube standard agglutination assay. For all the antigens tested, 100% concordance was achieved. The flow-cytometry-based method used minimal reagent volume (0.5-1 mu l per antigen) compared with the volumes required for manual tube standard agglutination (50 mu l per antigen)Conclusion This study demonstrates the successful validation of flow-cytometry-based RBC phenotyping. Flow cytometry offers many benefits compared to common conventional RBC phenotyping methods including high degrees of automation, quantitative assessment with automated interpretation of results and extremely low volumes of reagents. This method could be used for high-throughput, low-cost phenotyping for both blood suppliers and hospital BTS.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 50 条
  • [21] Application of image flow cytometry for the characterization of red blood cell morphology
    Pinto, Ruben N.
    Sebastian, Joseph A.
    Parsons, Michael
    Chang, Tim C.
    Acker, Jason P.
    Kolios, Michael C.
    HIGH-SPEED BIOMEDICAL IMAGING AND SPECTROSCOPY: TOWARD BIG DATA INSTRUMENTATION AND MANAGEMENT II, 2017, 10076
  • [22] Photothermal Enhancement of Ion Current for Red Blood Cell Flow Cytometry
    Lee, Chang Heon
    Kim, Ji Tae
    Jeong, Dong-won
    Lee, Sang Hyun
    Kim, Yoonhee
    Han, Seok Hee
    Shin, Myeongsik
    Chung, Taek Dong
    ANALYTICAL CHEMISTRY, 2024, 96 (35) : 14178 - 14185
  • [23] A weakly supervised deep learning approach for label-free imaging flow-cytometry-based blood diagnostics
    Otesteanu, Corin F.
    Ugrinic, Martina
    Holzner, Gregor
    Chang, Yun-Tsan
    Fassnacht, Christina
    Guenova, Emmanuella
    Stavrakis, Stavros
    DeMello, Andrew
    Claassen, Manfred
    CELL REPORTS METHODS, 2021, 1 (06):
  • [24] Applications of Flow Cytometry in Diagnosis and Evaluation of Red Blood Cell Disorders
    Dadelahi, Alexis
    Jackson, Taylor
    Agarwal, Archana M.
    Lin, Leo
    V. Rets, Anton
    Ng, David P.
    CLINICS IN LABORATORY MEDICINE, 2024, 44 (03) : 495 - 509
  • [25] Quantitation and phenotyping of fetal RBCs in maternal blood by flow cytometry
    Kumpel, BM
    MacDonald, AP
    TRANSFUSION, 2003, 43 (03) : 416 - 417
  • [26] A Novel Rapid Method of Red Blood Cell and Platelet Permeabilization and Staining for Flow Cytometry AnalysisKey Terms
    Faure, Sixtine
    Van Agthoven, Andreas
    Bernot, Denis
    Altie, Alexandre
    Grino, Michel
    Alessi, Marie-Christine
    Malergue, Fabrice
    Canault, Matthias
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2019, 96 (05) : 426 - 435
  • [27] Calibration-Aimed Comparison of Image-Cytometry- and Flow-Cytometry-Based Approaches of Ploidy Analysis
    Jonas, Viktor Zoltan
    Paulik, Robert
    Kozlovszky, Miklos
    Molnar, Bela
    SENSORS, 2022, 22 (18)
  • [28] Flow Cytometry Method Validation Protocols
    Selliah, Nithianandan
    Nash, Veronica
    Eck, Steven
    Green, Cherie
    Oldaker, Teri
    Stewart, Jennifer
    Vitaliti, Alessandra
    Litwin, Virginia
    CURRENT PROTOCOLS, 2023, 3 (08):
  • [29] Flow-cytometry-based protocol to analyze respiratory chain function in mouse microglia
    Erny, Daniel
    Dokalis, Nikolaos
    Mezoe, Charlotte
    Mossad, Omar
    Blank, Thomas
    Prinz, Marco
    STAR PROTOCOLS, 2022, 3 (01):
  • [30] A Novel Flow-Cytometry-Based Assay for Cellular Uptake Studies of Polyelectrolyte Microcapsules
    Semmling, Maximilian
    Kreft, Oliver
    Javier, Almudena Munoz
    Sukhorukov, Gleb B.
    Kaes, Josef
    Parak, Wolfgang J.
    SMALL, 2008, 4 (10) : 1763 - 1768