Validation of a flow-cytometry-based red blood cell antigen phenotyping method

被引:6
|
作者
Liwski, Robert [1 ,2 ]
Clarke, Gwen [3 ,4 ]
Cheng, Calvino [1 ,2 ]
Abidi, Syed Sibte Raza [5 ]
Abidi, Samina Raza [6 ]
Quinn, Jason George [1 ,2 ,7 ]
机构
[1] Dalhousie Univ, Dept Pathol, Lab Med, Halifax, NS, Canada
[2] Nova Scotia Hlth Author, Cent Zone, Halifax, NS, Canada
[3] Univ Alberta, Dept Lab Med & Pathol, Edmonton, AB, Canada
[4] Canadian Blood Serv, Edmonton, AB, Canada
[5] Dalhousie Univ, Fac Comp Sci, Res Grp NICHE, Halifax, NS, Canada
[6] Dalhousie Univ, Fac Med, Dept Community Hlth & Epidemiol, Halifax, NS, Canada
[7] 5788 Univ Ave,Room 217, Halifax, NS B3H 1V8, Canada
关键词
antigen typing; flow cytometry; phenotyping; RBC phenotyping; transfusion; ALLOIMMUNIZATION; TRANSFUSIONS;
D O I
10.1111/vox.13401
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives Current manual and automated phenotyping methods are based on visual detection of the antigen-antibody interaction. This approach has several limitations including the use of large volumes of patient and reagent red blood cells (RBCs) and antisera to produce a visually detectable reaction. We sought to determine whether the flow cytometry could be developed and validated to perform RBC phenotyping to enable a high-throughput method of phenotyping using comparatively miniscule reagent volumes via fluorescence-based detection of antibody binding.Materials and Methods RBC phenotyping by flow cytometry was performed using monoclonal direct typing antisera (human IgM): anti-C, -E, -c, -e, -K, -Jk(a), -Jk(b) and indirect typing antisera (human IgG): anti-k, -Fy(a), -Fy(b), -S, -s that are commercially available and currently utilized in our blood transfusion services (BTS) for agglutination-based phenotyping assays.Results Seventy samples were tested using both flow-cytometry-based-phenotyping and a manual tube standard agglutination assay. For all the antigens tested, 100% concordance was achieved. The flow-cytometry-based method used minimal reagent volume (0.5-1 mu l per antigen) compared with the volumes required for manual tube standard agglutination (50 mu l per antigen)Conclusion This study demonstrates the successful validation of flow-cytometry-based RBC phenotyping. Flow cytometry offers many benefits compared to common conventional RBC phenotyping methods including high degrees of automation, quantitative assessment with automated interpretation of results and extremely low volumes of reagents. This method could be used for high-throughput, low-cost phenotyping for both blood suppliers and hospital BTS.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 50 条
  • [31] A novel flow-cytometry-based assay for quantification of affinity and avidity changes of integrins
    Konstandin, MH
    Sester, U
    Klemke, M
    Weschenfelder, T
    Wabnitz, GH
    Samstag, Y
    JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 310 (1-2) : 67 - 77
  • [32] Red cell age by flow cytometry
    Nusbaum, NJ
    MEDICAL HYPOTHESES, 1997, 48 (06) : 469 - 472
  • [33] EXTENDED RED BLOOD CELL PHENOTYPING IN THE NETHERLANDS
    Boujnan, M.
    Sewsahai, R.
    Jongerius, J. M.
    VOX SANGUINIS, 2013, 105 : 200 - 200
  • [34] Protocol A flow-cytometry-based assessment of global protein synthesis in human senescent cells
    Lee, Yeonghyeon
    Kim, Jaejin
    Jeon, Taerang
    Roh, Kyeonghwan
    Kim, Mi-Sung
    Kang, Chanhee
    STAR PROTOCOLS, 2021, 2 (03):
  • [35] Development of multiplexed flow cytometry-based red blood cell antibody screen and identification assays
    Liwski, Robert
    Greenshields, Anna
    Grace, Ian
    Cheng, Calvino
    Quinn, Jason George
    VOX SANGUINIS, 2024, 119 (04) : 344 - 352
  • [36] Identifying red blood cell surface markers associated with neocytolysis by flow cytometry
    Chen, Y.
    Modi, K.
    Alfrey, C.
    Rice, L.
    Chang, C-C
    LABORATORY INVESTIGATION, 2008, 88 : 248A - 248A
  • [37] Identifying red blood cell surface markers associated with neocytolysis by flow cytometry
    Chen, Y.
    Modi, K.
    Alfrey, C.
    Rice, L.
    Chang, C-C
    MODERN PATHOLOGY, 2008, 21 : 248A - 248A
  • [38] Aplication of flow cytometry in determination of sub-population of red blood cell
    Lebensohn, N.
    Di Tullio, L.
    Valverde, J.
    Foresto, P.
    VOX SANGUINIS, 2006, 91 : 120 - 120
  • [39] Measuring the red blood cell shape in capillary flow using spectrally encoded flow cytometry
    Fridman, Lidan
    Yelin, Dvir
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (09) : 4583 - 4591
  • [40] An easy and reliable whole blood freezing method for flow cytometry immuno-phenotyping and functional analyses
    Braudeau, Cecile
    Salabert-Le Guen, Nina
    Chevreuil, Justine
    Rimbert, Marie
    Martin, Jerome C.
    Josien, Regis
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2021, 100 (06) : 652 - 665