Cervical Range of Motion Analysis Performed with an Accelerometer: A Study of Intersession Reliability for Dental Practice

被引:1
|
作者
Nota, Alessandro [1 ,2 ]
Pittari, Laura [1 ,2 ,3 ]
Gamba, Laura [1 ,2 ]
Monticciolo, Francesco Manfredi [1 ,2 ]
Lannes, Alessia [1 ,2 ]
Carta, Carlotta [1 ,2 ]
Beraldi, Alessandro
Baldini, Alberto
Marzo, Giuseppe [3 ]
Tecco, Simona [1 ,2 ]
机构
[1] Univ Vita Salute San Raffaele, Dent Sch, I-20132 Milan, Italy
[2] IRCCS San Raffaele Hosp, Dept Dent, I-20132 Milan, Italy
[3] Univ LAquila, Dept Clin Med Publ Hlth Life & Environm Sci MeSVA, I-24100 Laquila, Italy
关键词
cranio-cervical-mandibular disorders; accelerometer; range of motion; digital dentistry; temporomandibular disorders; intersession reliability; MANDIBULAR POSITION; CRANIOCERVICAL POSTURE; ISOMETRIC STRENGTH; VERTICAL DIMENSION; HEAD; PAIN; NECK; MUSCLES; OCCLUSION;
D O I
10.3390/healthcare11101428
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
During the clinical examination of subjects with temporomandibular disorders (TMDs), the dentist sometimes must evaluate the cervical spine, due to the anatomical and functional connections between the cervical portion of the spine and the stomatognathic apparatus. The accelerometer is a device that evaluates the Range of Motion (ROM) of the main movements of the head on the neck. To date, only a few studies have investigated the repeatability of the use of the accelerometer in the assessment of cervical ROM. Therefore, the present longitudinal observational study analyzed the repeatability of acquired cervical movements on a sample of volunteer subjects who underwent accelerometer testing. A sample of 32 subjects was tested twice within 14 days to assess cervical ROM using a standardized protocol based on a review of existing literature. The results show that the examination is reliable for all the positions of the jaw, except for the parameters regarding the asymmetries of rotation and bending. In conclusion, the accelerometer can be considered a reliable tool for evaluating the active cervical ROM. However, further studies will be necessary to make better evaluations.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Range of global motion of the cervical spine: intraindividual reliability and the influence of measurement device
    Mannion, AF
    Klein, GN
    Dvorak, J
    Lanz, C
    EUROPEAN SPINE JOURNAL, 2000, 9 (05) : 379 - 385
  • [22] Validity and Between-Day Reliability of the Cervical Range of Motion (CROM) Device
    Audette, Isabel
    Dumas, Jean-Pierre
    Cote, Julie N.
    De Serres, Sophie J.
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2010, 40 (05): : 318 - 323
  • [23] Evaluation of cervical range of motion and isometric neck muscle strength: reliability and validity
    Chiu, TTW
    Lo, SK
    CLINICAL REHABILITATION, 2002, 16 (08) : 851 - 858
  • [24] Range of global motion of the cervical spine: intraindividual reliability and the influence of measurement device
    A. F. Mannion
    G. N. Klein
    J. Dvorak
    C. Lanz
    European Spine Journal, 2000, 9 : 379 - 385
  • [25] The reliability and accuracy of an electromagnetic motion analysis system when used conjointly with an accelerometer
    Ribeiro, D. C.
    Sole, G.
    Abbott, J. H.
    Milosavljevic, S.
    ERGONOMICS, 2011, 54 (07) : 672 - 677
  • [26] Reliability of the Spin-T cervical goniometer in measuring cervical range of motion in an asymptomatic Indian population
    Agarwal, S
    Allison, GT
    Singer, KP
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2005, 28 (07) : 487 - 492
  • [27] Reliability of cervical range of motion using the OSICA 6000 Spine Motion Analyser on asymptomatic and symptomatic subjects
    Petersen, CM
    Johnson, RD
    Schuit, D
    MANUAL THERAPY, 2000, 5 (02) : 82 - 88
  • [28] Goniometry and fleximetry measurements to assess cervical range of motion in individuals with chronic neck pain: a validity and reliability study
    Araujo, Gabriel Gardhel Costa
    Pontes-Silva, Andre
    Leal, Plinio da Cunha
    Gomes, Bruno Sousa
    Reis, Maisa Lopes
    Lima, Samira Kennia de Mello Pereira
    Fidelis-de-Paula-Gomes, Cid Andre
    Dibai-Filho, Almir Vieira
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [29] INTRASUBJECT RELIABILITY OF SPINAL RANGE OF MOTION AND VELOCITY DETERMINED BY VIDEO MOTION ANALYSIS
    ROBINSON, ME
    OCONNOR, PD
    SHIRLEY, FR
    MACMILLAN, M
    PHYSICAL THERAPY, 1993, 73 (09): : 626 - 631
  • [30] Criterion validity study of the cervical range of motion (CROM) device for rotational range of motion on healthy adults
    Tousignant, M
    Smeesters, C
    Breton, AM
    Breton, M
    Corriveau, H
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2006, 36 (04): : 242 - 248