INTRASUBJECT RELIABILITY OF SPINAL RANGE OF MOTION AND VELOCITY DETERMINED BY VIDEO MOTION ANALYSIS

被引:19
|
作者
ROBINSON, ME
OCONNOR, PD
SHIRLEY, FR
MACMILLAN, M
机构
[1] UNIV FLORIDA, CTR MUSCULOSKELETAL RES, DEPT CLIN & HLTH PSYCHOL, GAINESVILLE, FL 32610 USA
[2] UNIV FLORIDA, DEPT ORTHOPAED, GAINESVILLE, FL 32610 USA
[3] SHANDS TEACHING HOSP & CLIN INC, SPINAL TREATMENT & REHABIL PROGRAM, GAINESVILLE, FL 32610 USA
来源
PHYSICAL THERAPY | 1993年 / 73卷 / 09期
关键词
BACKACHE; MOVEMENT SCIENCE; SPINE; TESTS AND MEASUREMENTS; RANGE OF MOTION;
D O I
10.1093/ptj/73.9.626
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. The purpose of this study was to investigate the repeatability of spinal range of motion (ROM) and movement velocity measurements of patients with chronic low back pain, using a two-dimensional motion analysis system. This apparatus uses reflective markers placed on anatomical landmarks and video digitization to derive ROM measurements from three segments of the spine and associated velocities through the respective ROMs. Subjects. Forty-two patients with chronic LBP underwent ROM and movement velocity testing. Methods. Each subject was tested twice without removal of the markers to minimize error contribution from differences in marker placement. Results. Results indicated that both the ROM measures and the velocity measures were highly repeatable intra-class correlations for the ROM measures ranged from .77 to .96. Velocity measures were also reliable, with intraclass correlation coefficients ranging from .75 to .97 Conclusion and Discussion. Overall, the results seem to indicate that the video motion analysis system used in this system yields repeatable ROM and velocity measures on a clinical population. In practice, however, the measures may reflect greater errors due to the need of examiners to relocate markers at different testing sessions. These system also offer distinct advantages over other means of obtaining ROM and velocity measures. The results of this study indicate that these measures may be obtained without undue concern for measurement artifact due to the instrumentation reliability.
引用
收藏
页码:626 / 631
页数:6
相关论文
共 50 条
  • [1] THE EFFECT OF MARKER PLACEMENT DEVIATIONS ON SPINAL RANGE OF MOTION DETERMINED BY VIDEO MOTION ANALYSIS
    OCONNOR, PD
    ROBINSON, ME
    SHIRLEY, FR
    MACMILLAN, M
    PHYSICAL THERAPY, 1993, 73 (07): : 478 - 483
  • [2] Reliability of measures for spinal range of motion in healthy
    Uhlemann, C
    Schreiber, TU
    Sarafowa, A
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2001, 11 (05) : 165 - 170
  • [3] The reliability of video based time motion analysis
    Duthie, G
    Pyne, D
    Hooper, S
    JOURNAL OF HUMAN MOVEMENT STUDIES, 2003, 44 (03): : 259 - 271
  • [4] Reliability of Video Motion-Analysis Systems to Measure Amplitude and Velocity of Shoulder Elevation
    Melton, Christopher
    Mullineaux, David R.
    Mattacola, Carl G.
    Mair, Scott D.
    Uhl, Tim L.
    JOURNAL OF SPORT REHABILITATION, 2011, 20 (04) : 393 - 405
  • [5] Reliability of lumbar spinal palpation, range of motion, and determination of position
    Troke, Michael
    Schuit, Dale
    Petersen, Cheryl M.
    BMC MUSCULOSKELETAL DISORDERS, 2007, 8 (1)
  • [6] Reliability of lumbar spinal palpation, range of motion, and determination of position
    Michael Troke
    Dale Schuit
    Cheryl M Petersen
    BMC Musculoskeletal Disorders, 8
  • [7] Video based measurement of sagittal range of spinal motion in young and older adults
    Kuo, Yi-Liang
    Tully, Elizabeth A.
    Galea, Mary P.
    MANUAL THERAPY, 2009, 14 (06) : 618 - 622
  • [8] Reliability and Validity of Quantitative Video Analysis of Baseball Pitching Motion
    Oyama, Sakiko
    Sosa, Araceli
    Campbell, Rebekah
    Correa, Alexandra
    JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (01) : 64 - 68
  • [9] RELIABILITY OF AN ACCELEROMETER-BASED SYSTEM FOR QUANTIFYING MULTIREGIONAL SPINAL RANGE OF MOTION
    Alqhtani, Raee S.
    Jones, Michael D.
    Theobald, Peter S.
    Williams, Jonathan M.
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2015, 38 (04) : 275 - 281
  • [10] Reliability and validity of smartphone applications to measure the spinal range of motion: A systematic review
    Nuhmani, Shibili
    Khan, Moazzam Hussain
    Kachanathu, Shaji J.
    Bari, Mohd Arshad
    Abualait, Turki S.
    Muaidi, Qassim, I
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (09) : 893 - 901