INTRASUBJECT RELIABILITY OF SPINAL RANGE OF MOTION AND VELOCITY DETERMINED BY VIDEO MOTION ANALYSIS

被引:19
|
作者
ROBINSON, ME
OCONNOR, PD
SHIRLEY, FR
MACMILLAN, M
机构
[1] UNIV FLORIDA, CTR MUSCULOSKELETAL RES, DEPT CLIN & HLTH PSYCHOL, GAINESVILLE, FL 32610 USA
[2] UNIV FLORIDA, DEPT ORTHOPAED, GAINESVILLE, FL 32610 USA
[3] SHANDS TEACHING HOSP & CLIN INC, SPINAL TREATMENT & REHABIL PROGRAM, GAINESVILLE, FL 32610 USA
来源
PHYSICAL THERAPY | 1993年 / 73卷 / 09期
关键词
BACKACHE; MOVEMENT SCIENCE; SPINE; TESTS AND MEASUREMENTS; RANGE OF MOTION;
D O I
10.1093/ptj/73.9.626
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. The purpose of this study was to investigate the repeatability of spinal range of motion (ROM) and movement velocity measurements of patients with chronic low back pain, using a two-dimensional motion analysis system. This apparatus uses reflective markers placed on anatomical landmarks and video digitization to derive ROM measurements from three segments of the spine and associated velocities through the respective ROMs. Subjects. Forty-two patients with chronic LBP underwent ROM and movement velocity testing. Methods. Each subject was tested twice without removal of the markers to minimize error contribution from differences in marker placement. Results. Results indicated that both the ROM measures and the velocity measures were highly repeatable intra-class correlations for the ROM measures ranged from .77 to .96. Velocity measures were also reliable, with intraclass correlation coefficients ranging from .75 to .97 Conclusion and Discussion. Overall, the results seem to indicate that the video motion analysis system used in this system yields repeatable ROM and velocity measures on a clinical population. In practice, however, the measures may reflect greater errors due to the need of examiners to relocate markers at different testing sessions. These system also offer distinct advantages over other means of obtaining ROM and velocity measures. The results of this study indicate that these measures may be obtained without undue concern for measurement artifact due to the instrumentation reliability.
引用
收藏
页码:626 / 631
页数:6
相关论文
共 50 条
  • [21] Dynamic search range motion estimation for video coding
    Liu, LK
    1997 IEEE FIRST WORKSHOP ON MULTIMEDIA SIGNAL PROCESSING, 1997, : 207 - 212
  • [22] Measurement of spinal range of motion using two-dimensional motion analysis system in patients with low back pain
    Kim, Y
    Yang, S
    Kang, S
    Son, S
    Kim, M
    8TH WORLD CONGRESS OF THE INTERNATIONAL REHABILITATION MEDICINE ASSOCIATION (IRMA VIII), PTS 1-2, 1997, : 361 - 365
  • [23] The reliability of shoulder range of motion measures in competitive swimmers
    Walker, Helen
    Pizzari, Tania
    Wajswelner, Henry
    Blanch, Peter
    Schwab, Laura
    Bennell, Kim
    Gabbe, Belinda
    PHYSICAL THERAPY IN SPORT, 2016, 21 : 26 - 30
  • [24] Reliability of mandibular range of motion measurements in healthy children
    de Sonnaville, Willemijn F. C.
    Steenks, Michel H.
    Verkouteren, Daan R. C.
    Zuithoff, Nicolaas P. A.
    Wulffraat, Nico M.
    Rosenberg, Antoine J. W. P.
    Speksnijder, Caroline M.
    JOURNAL OF ORAL REHABILITATION, 2024,
  • [25] THE RELIABILITY OF FABER TEST HIP RANGE OF MOTION MEASUREMENTS
    Bagwell, Jennifer J.
    Bauer, Lauren
    Gradoz, Marissa
    Grindstaff, Terry L.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2016, 11 (07): : 1101 - 1105
  • [26] Reliability of range-of-motion measurement in the elbow and forearm
    Armstrong, AD
    MacDermid, JC
    Chinchalkar, S
    Stevens, RS
    King, GJW
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (06) : 573 - 580
  • [27] Accuracy and reliability for estimating jaw functional range of motion
    Nilsson, Evelina
    Grip, Helena
    Osterlund, Catharina
    GAIT & POSTURE, 2024, 113 : 280 - 286
  • [28] RELIABILITY OF THREE MEASURES OF ANKLE DORSIFLEXION RANGE OF MOTION
    Konor, Megan M.
    Morton, Sam
    Eckerson, Joan M.
    Grindstaff, Terry L.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2012, 7 (03): : 279 - 287
  • [29] RELIABILITY AND USE OF THE INCLINOMETER FOR CERVICAL RANGE OF MOTION MEASUREMENTS
    BARBEE, JA
    SANDSTEDT, AE
    PANICHELLA, JL
    CRANDELL, CE
    PHYSICAL THERAPY, 1988, 68 (05): : 826 - 827
  • [30] Reliability of five methods for assessing shoulder range of motion
    Hayes, K
    Walton, JR
    Szomor, ZL
    Murrell, GAC
    AUSTRALIAN JOURNAL OF PHYSIOTHERAPY, 2001, 47 (04): : 289 - 294