The reliability and accuracy of an electromagnetic motion analysis system when used conjointly with an accelerometer

被引:6
|
作者
Ribeiro, D. C. [1 ]
Sole, G. [1 ]
Abbott, J. H. [1 ]
Milosavljevic, S. [1 ]
机构
[1] Univ Otago, Dunedin, New Zealand
关键词
accelerometer; accuracy; electromagnetic device; reliability; validity; MOVEMENT; FLEXION;
D O I
10.1080/00140139.2011.583363
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The effect of an accelerometer driven electronic postural monitor (Spineangel (R)) placed within the electromagnetic measurement field of the Polhemus Fastrak (TM) is unknown. This study assessed the reliability and accuracy of Fastrak (TM) linear and angular measurements, when the Spineangel (R) was placed close to the sensor(s) and transmitter. Bland Altman plots and intraclass correlation coefficient (2,1) were used to determine protocol reproducibility and measurement consistency. Excellent reliability was found for linear and angular measurements (0.96, 95% CI: 0.90-0.99; and 1.00, 95% CI: 1.00-1.00, respectively) with the inclusion of Spineangel (R); similar results were found, without the inclusion of Spineangel (R), for linear and angular measurements, (0.96, 95% CI: 0.89-0.99; and 1.00, 95% CI: 1.00-1.00, respectively). The greatest linear discrepancies between the two test conditions were found to be less than 3.5 mm, while the greatest angular discrepancies were below 3.5 degrees. As the effect on accuracy was minimal, these findings support the conjoint use of the Fastrak (TM) during validation studies of the Spineangel (R) device.
引用
收藏
页码:672 / 677
页数:6
相关论文
共 50 条
  • [1] RELIABILITY ANALYSIS OF A SYSTEM WHEN IT IS USED INTERMITTENTLY
    OSAKI, S
    ELECTRONICS & COMMUNICATIONS IN JAPAN, 1971, 54 (01): : 131 - &
  • [2] MEMS Accelerometer Based System for Motion Analysis
    Awasthi, Sonal
    Joshi, Atul
    2015 2ND INTERNATIONAL CONFERENCE ON ELECTRONICS AND COMMUNICATION SYSTEMS (ICECS), 2015, : 762 - 767
  • [3] RELIABILITY OF AN ACCELEROMETER-BASED SYSTEM FOR QUANTIFYING MULTIREGIONAL SPINAL RANGE OF MOTION
    Alqhtani, Raee S.
    Jones, Michael D.
    Theobald, Peter S.
    Williams, Jonathan M.
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2015, 38 (04) : 275 - 281
  • [4] The effect of transponder motion on the accuracy of the Calypso electromagnetic localization system
    Murphy, M. J.
    Eidens, R.
    Vertatschitsch, E.
    Wright, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S615 - S615
  • [5] Accuracy and reliability of tridimensional electromagnetic sensor system for elbow ROM measurement
    Kohei Yamaura
    Yutaka Mifune
    Atsuyuki Inui
    Hanako Nishimoto
    Takeshi Kataoka
    Takashi Kurosawa
    Shintaro Mukohara
    Yuichi Hoshino
    Takahiro Niikura
    Kouki Nagamune
    Ryosuke Kuroda
    Journal of Orthopaedic Surgery and Research, 17
  • [6] Accuracy and reliability of tridimensional electromagnetic sensor system for elbow ROM measurement
    Yamaura, Kohei
    Mifune, Yutaka
    Inui, Atsuyuki
    Nishimoto, Hanako
    Kataoka, Takeshi
    Kurosawa, Takashi
    Mukohara, Shintaro
    Hoshino, Yuichi
    Niikura, Takahiro
    Nagamune, Kouki
    Kuroda, Ryosuke
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [7] Accuracy and reliability of observational motion analysis in identifying shoulder symptoms
    Hickey, Brendan W.
    Milosavjevic, Stephan
    Bell, Melanie L.
    Milburn, Peter D.
    MANUAL THERAPY, 2007, 12 (03) : 263 - 270
  • [8] Cervical Range of Motion Analysis Performed with an Accelerometer: A Study of Intersession Reliability for Dental Practice
    Nota, Alessandro
    Pittari, Laura
    Gamba, Laura
    Monticciolo, Francesco Manfredi
    Lannes, Alessia
    Carta, Carlotta
    Beraldi, Alessandro
    Baldini, Alberto
    Marzo, Giuseppe
    Tecco, Simona
    HEALTHCARE, 2023, 11 (10)
  • [9] RELIABILITY-ANALYSIS OF AN INTERMITTENTLY USED SYSTEM
    SRINIVASAN, SK
    MICROELECTRONICS AND RELIABILITY, 1983, 23 (02): : 295 - 308
  • [10] Accuracy, reliability, and validity of a spatiotemporal gait analysis system
    Barker, S
    Craik, R
    Freedman, W
    Herrmann, N
    Hillstrom, H
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (05) : 460 - 467