Cervical Range of Motion Analysis Performed with an Accelerometer: A Study of Intersession Reliability for Dental Practice

被引:1
|
作者
Nota, Alessandro [1 ,2 ]
Pittari, Laura [1 ,2 ,3 ]
Gamba, Laura [1 ,2 ]
Monticciolo, Francesco Manfredi [1 ,2 ]
Lannes, Alessia [1 ,2 ]
Carta, Carlotta [1 ,2 ]
Beraldi, Alessandro
Baldini, Alberto
Marzo, Giuseppe [3 ]
Tecco, Simona [1 ,2 ]
机构
[1] Univ Vita Salute San Raffaele, Dent Sch, I-20132 Milan, Italy
[2] IRCCS San Raffaele Hosp, Dept Dent, I-20132 Milan, Italy
[3] Univ LAquila, Dept Clin Med Publ Hlth Life & Environm Sci MeSVA, I-24100 Laquila, Italy
关键词
cranio-cervical-mandibular disorders; accelerometer; range of motion; digital dentistry; temporomandibular disorders; intersession reliability; MANDIBULAR POSITION; CRANIOCERVICAL POSTURE; ISOMETRIC STRENGTH; VERTICAL DIMENSION; HEAD; PAIN; NECK; MUSCLES; OCCLUSION;
D O I
10.3390/healthcare11101428
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
During the clinical examination of subjects with temporomandibular disorders (TMDs), the dentist sometimes must evaluate the cervical spine, due to the anatomical and functional connections between the cervical portion of the spine and the stomatognathic apparatus. The accelerometer is a device that evaluates the Range of Motion (ROM) of the main movements of the head on the neck. To date, only a few studies have investigated the repeatability of the use of the accelerometer in the assessment of cervical ROM. Therefore, the present longitudinal observational study analyzed the repeatability of acquired cervical movements on a sample of volunteer subjects who underwent accelerometer testing. A sample of 32 subjects was tested twice within 14 days to assess cervical ROM using a standardized protocol based on a review of existing literature. The results show that the examination is reliable for all the positions of the jaw, except for the parameters regarding the asymmetries of rotation and bending. In conclusion, the accelerometer can be considered a reliable tool for evaluating the active cervical ROM. However, further studies will be necessary to make better evaluations.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion
    Gao, Zhongyang
    Song, Hui
    Ren, Fenggang
    Li, Yuhuan
    Wang, Dong
    He, Xijing
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (06) : 5371 - 5378
  • [2] Cervical Range of Motion Assessment through Inertial Technology: A Validity and Reliability Study
    Palmieri, Martina
    Donno, Lucia
    Cimolin, Veronica
    Galli, Manuela
    SENSORS, 2023, 23 (13)
  • [3] RELIABILITY AND USE OF THE INCLINOMETER FOR CERVICAL RANGE OF MOTION MEASUREMENTS
    BARBEE, JA
    SANDSTEDT, AE
    PANICHELLA, JL
    CRANDELL, CE
    PHYSICAL THERAPY, 1988, 68 (05): : 826 - 827
  • [4] INTRATESTER AND INTERTESTER RELIABILITY OF THE CERVICAL RANGE OF MOTION DEVICE
    CAPUANOPUCCI, D
    RHEAULT, W
    AUKAI, J
    BRACKE, M
    DAY, R
    PASTRICK, M
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1991, 72 (05): : 338 - 340
  • [5] RELIABILITY OF AN ACCELEROMETER-BASED SYSTEM FOR QUANTIFYING MULTIREGIONAL SPINAL RANGE OF MOTION
    Alqhtani, Raee S.
    Jones, Michael D.
    Theobald, Peter S.
    Williams, Jonathan M.
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2015, 38 (04) : 275 - 281
  • [6] Reliability of Smartphone Inclinometry to Measure Upper Cervical Range of Motion
    Ullucci, Paul A.
    Tudini, Frank
    Moran, Matthew F.
    JOURNAL OF SPORT REHABILITATION, 2019, 28 (01) : 1 - 3
  • [7] Reliability and Validity of Cervical Range of Motion and Muscle Strength Testing
    Kubas, Christian
    Chen, Yi-Wen
    Echeverri, Silvana
    McCann, Stephanie L.
    Denhoed, Marcia J.
    Walker, Catherine J.
    Kennedy, Carol N.
    Reid, W. Darlene
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (04) : 1087 - 1096
  • [8] Measuring Lumbar Motion Angle With a Small Accelerometer: A Reliability Study
    Miyachi, Ryo
    Sano, Ayaka
    Tanaka, Nana
    Tamai, Misaki
    Miyazaki, Junya
    JOURNAL OF CHIROPRACTIC MEDICINE, 2022, 21 (01) : 32 - 38
  • [9] Standardized initial head position in cervical range-of-motion assessment: Reliability and error analysis
    Solinger, AB
    Chen, J
    Lantz, CA
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2000, 23 (01) : 20 - 26
  • [10] Reliability of the Cervical Spine Device for the Assessment of Cervical Spine Range of Motion in Asymptomatic Participants
    Mangone, Massimiliano
    Bernetti, Andrea
    Germanotta, Marco
    Di Sipio, Enrica
    Razzano, Cristina
    Ioppolo, Francesco
    Santilli, Valter
    Venditto, Teresa
    Paoloni, Marco
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2018, 41 (04) : 342 - 349