Reference values for 4D flow magnetic resonance imaging of the portal venous system

被引:5
|
作者
Huang, Andrew [1 ,2 ]
Roberts, Grant S. [3 ]
Roldan-Alzate, Alejandro [4 ,5 ]
Wieben, Oliver [3 ]
Reeder, Scott B. [1 ,3 ,5 ,6 ,7 ]
Oechtering, Thekla H. [1 ,8 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Michigan, Dept Surg, Vasc Surg Sect, Ann Arbor, MI 48109 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI USA
[4] Univ Wisconsin, Dept Mech Engn, Madison, WI USA
[5] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[6] Univ Wisconsin, Dept Med, Madison, WI USA
[7] Univ Wisconsin, Dept Emergency Med, Madison, WI USA
[8] Univ Lubeck, Dept Radiol & Nucl Med, Lubeck, Germany
关键词
4D flow MRI; Portal vein; Portal hypertension; Reference values; PHASE-CONTRAST MRI; BLOOD-FLOW; SPLANCHNIC ARTERIAL; HEMODYNAMICS; CIRRHOSIS; VISUALIZATION; FEASIBILITY; ANGIOGRAPHY; ULTRASOUND; PATTERNS;
D O I
10.1007/s00261-023-03892-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. Methods For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after >= 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean +/- 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. Results We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow ( 34%). Conservation of mass analysis demonstrated a relative error of 1.1 +/- 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 +/- 4.1% SD at the portal bifurcation. Conclusion We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts. [Graphical abstract]
引用
收藏
页码:2049 / 2059
页数:11
相关论文
共 50 条
  • [41] Pre- and post-operative assessment of valvular and aortic flow using 4D flow magnetic resonance imaging
    Manka, Robert
    Busch, Julia
    Crelier, Gerard
    Luescher, Thomas F.
    Kozerke, Sebastian
    EUROPEAN HEART JOURNAL, 2013, 34 (19) : 1423 - 1423
  • [42] 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
    Malenka M. Bissell
    Francesca Raimondi
    Lamia Ait Ali
    Bradley D. Allen
    Alex J. Barker
    Ann Bolger
    Nicholas Burris
    Carl-Johan Carhäll
    Jeremy D. Collins
    Tino Ebbers
    Christopher J. Francois
    Alex Frydrychowicz
    Pankaj Garg
    Julia Geiger
    Hojin Ha
    Anja Hennemuth
    Michael D. Hope
    Albert Hsiao
    Kevin Johnson
    Sebastian Kozerke
    Liliana E. Ma
    Michael Markl
    Duarte Martins
    Marci Messina
    Thekla H. Oechtering
    Pim van Ooij
    Cynthia Rigsby
    Jose Rodriguez-Palomares
    Arno A. W. Roest
    Alejandro Roldán-Alzate
    Susanne Schnell
    Julio Sotelo
    Matthias Stuber
    Ali B. Syed
    Johannes Töger
    Rob van der Geest
    Jos Westenberg
    Liang Zhong
    Yumin Zhong
    Oliver Wieben
    Petter Dyverfeldt
    Journal of Cardiovascular Magnetic Resonance, 25
  • [43] Special Issue on 4D Flow MRI in Magnetic Resonance in Medical Sciences
    Markl, Michael
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 257 - 257
  • [44] 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
    Bissell, Malenka M.
    Raimondi, Francesca
    Ait Ali, Lamia
    Allen, Bradley D.
    Barker, Alex J.
    Bolger, Ann
    Burris, Nicholas
    Carhaell, Carl-Johan
    Collins, Jeremy D.
    Ebbers, Tino
    Francois, Christopher J.
    Frydrychowicz, Alex
    Garg, Pankaj
    Geiger, Julia
    Ha, Hojin
    Hennemuth, Anja
    Hope, Michael D.
    Hsiao, Albert
    Johnson, Kevin
    Kozerke, Sebastian
    Ma, Liliana E.
    Markl, Michael
    Martins, Duarte
    Messina, Marci
    Oechtering, Thekla H.
    van Ooij, Pim
    Rigsby, Cynthia
    Rodriguez-Palomares, Jose
    Roest, Arno A. W.
    Roldan-Alzate, Alejandro
    Schnell, Susanne
    Sotelo, Julio
    Stuber, Matthias
    Syed, Ali B.
    Toeger, Johannes
    van der Geest, Rob
    Westenberg, Jos
    Zhong, Liang
    Zhong, Yumin
    Wieben, Oliver
    Dyverfeldt, Petter
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [45] Interactive effect of hemodynamics in transverse sigmoid sinus and bone morphology on venous pulsatile tinnitus: a fourdimensional (4D) flow magnetic resonance imaging (MRI) study
    Lv, Ke
    Zheng, Shaowei
    Wang, Huiying
    Zhao, Chenxi
    Yu, Zhuo
    Shen, Zhiwei
    Xu, Kaixu
    Chai, Chao
    Xia, Shuang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (09)
  • [46] Improving visualization of 4D flow cardiovascular magnetic resonance with four-dimensional angiographic data: generation of a 4D phase-contrast magnetic resonance CardioAngiography (4D PC-MRCA)
    Bustamante, Mariana
    Gupta, Vikas
    Carlhall, Carl-Johan
    Ebbers, Tino
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [47] Improving visualization of 4D flow cardiovascular magnetic resonance with four-dimensional angiographic data: generation of a 4D phase-contrast magnetic resonance CardioAngiography (4D PC-MRCA)
    Mariana Bustamante
    Vikas Gupta
    Carl-Johan Carlhäll
    Tino Ebbers
    Journal of Cardiovascular Magnetic Resonance, 19
  • [48] A 4D volumetric imaging system
    Ansbro, E
    OPTP-IRELAND 2002: OPTICAL METROLOGY, IMAGING, AND MACHINE VISION, 2003, 4877 : 278 - 280
  • [49] Population-based reference values for 4D flow MRI derived aortic blood flow parameters
    Schafstedde, Marie
    Jarmatz, Lina
    Bruening, Jan
    Huellebrand, Markus
    Nordmeyer, Sarah
    Harloff, Andreas
    Hennemuth, Anja
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (03)
  • [50] Particle Tracing Based on 4D Flow Magnetic Resonance Imaging: A Systematic Review into Methods, Applications, and Current Developments
    Roos, Paul R.
    Rijnberg, Friso M.
    Westenberg, Jos J. M.
    Lamb, Hildo J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (05) : 1320 - 1339