Reference values for 4D flow magnetic resonance imaging of the portal venous system

被引:5
|
作者
Huang, Andrew [1 ,2 ]
Roberts, Grant S. [3 ]
Roldan-Alzate, Alejandro [4 ,5 ]
Wieben, Oliver [3 ]
Reeder, Scott B. [1 ,3 ,5 ,6 ,7 ]
Oechtering, Thekla H. [1 ,8 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Michigan, Dept Surg, Vasc Surg Sect, Ann Arbor, MI 48109 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI USA
[4] Univ Wisconsin, Dept Mech Engn, Madison, WI USA
[5] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[6] Univ Wisconsin, Dept Med, Madison, WI USA
[7] Univ Wisconsin, Dept Emergency Med, Madison, WI USA
[8] Univ Lubeck, Dept Radiol & Nucl Med, Lubeck, Germany
关键词
4D flow MRI; Portal vein; Portal hypertension; Reference values; PHASE-CONTRAST MRI; BLOOD-FLOW; SPLANCHNIC ARTERIAL; HEMODYNAMICS; CIRRHOSIS; VISUALIZATION; FEASIBILITY; ANGIOGRAPHY; ULTRASOUND; PATTERNS;
D O I
10.1007/s00261-023-03892-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. Methods For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after >= 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean +/- 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. Results We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow ( 34%). Conservation of mass analysis demonstrated a relative error of 1.1 +/- 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 +/- 4.1% SD at the portal bifurcation. Conclusion We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts. [Graphical abstract]
引用
收藏
页码:2049 / 2059
页数:11
相关论文
共 50 条
  • [31] The Assessment of Aortic Pulse Wave Velocity Using 4D Flow Magnetic Resonance Imaging: Methods Comparison
    Houriez-Gombaud-Saintonge, Sophia
    Mousseaux, Elie
    Bargiotas, Ioannis
    De Cesare, Alain
    Dietenbeck, Thomas
    Bouaou, Kevin
    Redheuil, Alban
    Soulat, Gilles
    Gencer, Umit
    Craiem, Damian
    Chenoune, Yasmina
    Kachenoura, Nadjia
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [32] Novel Insights into Complex Cardiovascular Pathologies using 4D Flow Analysis by Cardiovascular Magnetic Resonance Imaging
    Lewandowski, Adam James
    Raman, Betty
    Banerjee, Rajarshi
    Milanesi, Matteo
    CURRENT PHARMACEUTICAL DESIGN, 2017, 23 (22) : 3262 - 3267
  • [33] Novel application of 4D flow magnetic resonance imaging in a neonatal post-operative aortic dissection
    Sassoon, Daniel J.
    Fujiwara, Takashi
    Mitchell, Max B.
    Di Maria, Michael
    Barker, Alex J.
    Browne, Lorna P.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (12) : 1435 - 1435
  • [34] Noninvasive 4D Flow Characterization in a Stirred Tank via Phase-Contrast Magnetic Resonance Imaging
    Janiga, Gabor
    Stucht, Daniel
    Bordas, Robert
    Temmel, Erik
    Seidel-Morgenstern, Andreas
    Thevenin, Dominique
    Speck, Oliver
    CHEMICAL ENGINEERING & TECHNOLOGY, 2017, 40 (07) : 1370 - 1377
  • [35] A multi-modality approach for enhancing 4D flow magnetic resonance imaging via sparse representation
    Zhang, Jiacheng
    Brindise, Melissa C.
    Rothenberger, Sean M.
    Markl, Michael
    Rayz, Vitaliy L.
    Vlachos, Pavlos P.
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2022, 19 (186)
  • [36] Analysis of the kinematic motion of the wrist from 4D magnetic resonance imaging
    Abbas, Batool
    Fishbaugh, James
    Petchprapa, Catherine
    Lattanzi, Riccardo
    Gerig, Guido
    MEDICAL IMAGING 2019: IMAGE PROCESSING, 2019, 10949
  • [37] Expedited 4D Magnetic Resonance Imaging: A Generalized Model and An Efficient Solution
    Du, D.
    Mutic, S.
    Li, H.
    Hu, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3539 - 3539
  • [38] Inflow Hemodynamics of Intracranial Aneurysms: A Comparison of Computational Fluid Dynamics and 4D Flow Magnetic Resonance Imaging
    Misaki, Kouichi
    Futami, Kazuya
    Uno, Takehiro
    Nambu, Iku
    Yoshikawa, Akifumi
    Kamide, Tomoya
    Nakada, Mitsutoshi
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (05):
  • [39] Prospective Quantification of Tricuspid Regurgitation With Transthoracic Echocardiography vs 4D Flow Cardiac Magnetic Resonance Imaging
    Sularz, Agata
    Negm, Ahmed
    Ponce, Alejandra Chavez
    El Shaer, Ahmed
    Bird, Jared
    Oh, Jae
    Collins, Jeremy
    Alkhouli, Mohamad
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B227 - B227
  • [40] Left ventricular diastolic early and late filling quantified from 4D flow magnetic resonance imaging
    Alattar, Yousef
    Soulat, Gilles
    Gencer, Umit
    Messas, Emmanuel
    Bollache, Emilie
    Kachenoura, Nadjia
    Mousseaux, Elie
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (7-8) : 345 - 352