Reference values for 4D flow magnetic resonance imaging of the portal venous system

被引:5
|
作者
Huang, Andrew [1 ,2 ]
Roberts, Grant S. [3 ]
Roldan-Alzate, Alejandro [4 ,5 ]
Wieben, Oliver [3 ]
Reeder, Scott B. [1 ,3 ,5 ,6 ,7 ]
Oechtering, Thekla H. [1 ,8 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Michigan, Dept Surg, Vasc Surg Sect, Ann Arbor, MI 48109 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI USA
[4] Univ Wisconsin, Dept Mech Engn, Madison, WI USA
[5] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[6] Univ Wisconsin, Dept Med, Madison, WI USA
[7] Univ Wisconsin, Dept Emergency Med, Madison, WI USA
[8] Univ Lubeck, Dept Radiol & Nucl Med, Lubeck, Germany
关键词
4D flow MRI; Portal vein; Portal hypertension; Reference values; PHASE-CONTRAST MRI; BLOOD-FLOW; SPLANCHNIC ARTERIAL; HEMODYNAMICS; CIRRHOSIS; VISUALIZATION; FEASIBILITY; ANGIOGRAPHY; ULTRASOUND; PATTERNS;
D O I
10.1007/s00261-023-03892-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. Methods For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after >= 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean +/- 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. Results We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow ( 34%). Conservation of mass analysis demonstrated a relative error of 1.1 +/- 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 +/- 4.1% SD at the portal bifurcation. Conclusion We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts. [Graphical abstract]
引用
收藏
页码:2049 / 2059
页数:11
相关论文
共 50 条
  • [21] Evaluation of bicuspid aortic valve and aortic coarctation with 4D flow magnetic resonance imaging
    Hope, Michael D.
    Meadows, Alison K.
    Hope, Thomas A.
    Ordovas, Karen G.
    Reddy, Gautham P.
    Alley, Marcus T.
    Higgins, Charles B.
    CIRCULATION, 2008, 117 (21) : 2818 - 2819
  • [22] 4D magnetic resonance flow imaging for estimating pulmonary vascular resistance in pulmonary hypertension
    Kheyfets, Vitaly O.
    Schafer, Michal
    Podgorski, Chris A.
    Schroeder, Joyce D.
    Browning, James
    Hertzberg, Jean
    Buckner, J. Kern
    Hunter, Kendal S.
    Shandas, Robin
    Fenster, Brett E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (04) : 914 - 922
  • [23] Age- and sex-specific reference values of biventricular flow components and kinetic energy by 4D flow cardiovascular magnetic resonance in healthy subjects
    Zhao, Xiaodan
    Tan, Ru-San
    Garg, Pankaj
    Chai, Ping
    Leng, Shuang
    Bryant, Jennifer Ann
    Teo, Lynette L. S.
    Yeo, Tee Joo
    Fortier, Marielle V.
    Low, Ting Ting
    Ong, Ching Ching
    Zhang, Shuo
    Van der Geest, Rob J.
    Allen, John C.
    Tan, Teng Hong
    Yip, James W.
    Tan, Ju Le
    Hughes, Marina
    Plein, Sven
    Westenberg, Jos J. M.
    Zhong, Liang
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [24] Age- and sex-specific reference values of biventricular flow components and kinetic energy by 4D flow cardiovascular magnetic resonance in healthy subjects
    Xiaodan Zhao
    Ru-San Tan
    Pankaj Garg
    Ping Chai
    Shuang Leng
    Jennifer Ann Bryant
    Lynette L. S. Teo
    Tee Joo Yeo
    Marielle V. Fortier
    Ting Ting Low
    Ching Ching Ong
    Shuo Zhang
    Rob J. Van der Geest
    John C. Allen
    Teng Hong Tan
    James W. Yip
    Ju Le Tan
    Marina Hughes
    Sven Plein
    Jos J. M. Westenberg
    Liang Zhong
    Journal of Cardiovascular Magnetic Resonance, 25
  • [25] Impaired Regulation of Portal Venous Flow in Response to a Meal Challenge as Quantified by 4D Flow MRI
    Roldan-Alzate, Alejandro
    Frydrychowicz, Alex
    Said, Adnan
    Johnson, Kevin M.
    Francois, Christopher J.
    Wieben, Oliver
    Reeder, Scott B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (04) : 1009 - 1017
  • [26] Intracranial 4D flow magnetic resonance imaging reveals altered haemodynamics in sickle cell disease
    Vaclavu, Lena
    Baldew, Zelonna A. V.
    Gevers, Sanna
    Mutsaerts, Henri J. M. M.
    Fijnvandraat, Karin
    Cnossen, Marjon H.
    Majoie, Charles B.
    Wood, John C.
    VanBavel, Ed
    Biemond, Bart J.
    van Ooij, Pim
    Nederveen, Aart J.
    BRITISH JOURNAL OF HAEMATOLOGY, 2018, 180 (03) : 432 - 442
  • [27] Blood flow visualization from 4D flow Magnetic Resonance Imaging using the ISO X3D standard
    Arbelaiz, Ander
    Bobeda, Javier
    Garcia, Sara
    Ruiz-Cabello, Jesus
    Garcia-Cosio, M. Dolores
    Lopez-Linares, Karen
    Posada, Jorge
    29TH INTERNATIONAL ACM CONFERENCE ON 3D WEB TECHNOLOGY, WEB3D 2024, 2024,
  • [28] 4D flow imaging with MRI
    Stankovic, Zoran
    Allen, Bradley D.
    Garcia, Julio
    Jarvis, Kelly B.
    Markl, Michael
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) : 173 - 192
  • [29] Determination of local flow ratios and velocities in a femoral venous cannula with computational fluid dynamics and 4D flow-sensitive magnetic resonance imaging: A method validation
    Rauh, Patrick
    Benk, Christoph
    Beyersdorf, Friedhelm
    Russe, Maximilian
    ARTIFICIAL ORGANS, 2021, 45 (05) : 506 - 515
  • [30] Complete Intracranial Arterial and Venous Blood Flow Evaluation with 4D Flow MR Imaging
    Hope, M. D.
    Purcell, D. D.
    Hope, T. A.
    von Morze, C.
    Vigneron, D. B.
    Alley, M. T.
    Dillon, W. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (02) : 362 - 366