Reference values for 4D flow magnetic resonance imaging of the portal venous system

被引:5
|
作者
Huang, Andrew [1 ,2 ]
Roberts, Grant S. [3 ]
Roldan-Alzate, Alejandro [4 ,5 ]
Wieben, Oliver [3 ]
Reeder, Scott B. [1 ,3 ,5 ,6 ,7 ]
Oechtering, Thekla H. [1 ,8 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[2] Univ Michigan, Dept Surg, Vasc Surg Sect, Ann Arbor, MI 48109 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI USA
[4] Univ Wisconsin, Dept Mech Engn, Madison, WI USA
[5] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[6] Univ Wisconsin, Dept Med, Madison, WI USA
[7] Univ Wisconsin, Dept Emergency Med, Madison, WI USA
[8] Univ Lubeck, Dept Radiol & Nucl Med, Lubeck, Germany
关键词
4D flow MRI; Portal vein; Portal hypertension; Reference values; PHASE-CONTRAST MRI; BLOOD-FLOW; SPLANCHNIC ARTERIAL; HEMODYNAMICS; CIRRHOSIS; VISUALIZATION; FEASIBILITY; ANGIOGRAPHY; ULTRASOUND; PATTERNS;
D O I
10.1007/s00261-023-03892-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. Methods For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after >= 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean +/- 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. Results We included 44 healthy subjects (26 female, 18-74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow ( 34%). Conservation of mass analysis demonstrated a relative error of 1.1 +/- 4.6% standard deviation (SD) at the splenomesenteric confluence and - 1.4 +/- 4.1% SD at the portal bifurcation. Conclusion We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts. [Graphical abstract]
引用
收藏
页码:2049 / 2059
页数:11
相关论文
共 50 条
  • [1] Reference values for 4D flow magnetic resonance imaging of the portal venous system
    Andrew Huang
    Grant S. Roberts
    Alejandro Roldán-Alzate
    Oliver Wieben
    Scott B. Reeder
    Thekla H. Oechtering
    Abdominal Radiology, 2023, 48 : 2049 - 2059
  • [2] 4D flow MR imaging of the portal venous system: a feasibility study in children
    Parekh, Keyur
    Markl, Michael
    Rose, Michael
    Schnell, Susanne
    Popescu, Andrada
    Rigsby, Cynthia K.
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 832 - 840
  • [3] 4D flow MR imaging of the portal venous system: a feasibility study in children
    Keyur Parekh
    Michael Markl
    Michael Rose
    Susanne Schnell
    Andrada Popescu
    Cynthia K. Rigsby
    European Radiology, 2017, 27 : 832 - 840
  • [4] 4D magnetic resonance flow imaging (4D flow MRI) in neonates Normal values, changes over time and feasibility
    Vejlstrup, A. M.
    Kromann, J.
    Bundgaard, H.
    Iversen, K.
    Vejlstrup, N.
    EUROPEAN HEART JOURNAL, 2018, 39 : 162 - 162
  • [5] 4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications
    Hyodo, Ryota
    Takehara, Yasuo
    Naganawa, Shinji
    RADIOLOGIA MEDICA, 2022, 127 (11): : 1181 - 1198
  • [6] 4D Flow MRI in the portal venous system: imaging and analysis methods, and clinical applications
    Ryota Hyodo
    Yasuo Takehara
    Shinji Naganawa
    La radiologia medica, 2022, 127 : 1181 - 1198
  • [7] Clinical Applications of 4D Flow MRI in the Portal Venous System
    Oechtering, Thekla H.
    Roberts, Grant S.
    Panagiotopoulos, Nikolaos
    Wieben, Oliver
    Reeder, Scott B.
    Roldan-Alzate, Alejandro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 340 - 353
  • [8] MAGNETIC-RESONANCE-IMAGING IN THE EVALUATION OF THE PORTAL VENOUS SYSTEM
    TAYLOR, CR
    MCCAULEY, TR
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 1992, 14 (03) : 268 - 273
  • [9] 4D cardiac magnetic resonance flow imaging in neonates - feasibility and reproducibility
    Vejlstrup, A.
    Iversen, K.
    Juul, K.
    Bundgaard, H.
    Kromann, J.
    Vejlstrup, N.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 202 - 202
  • [10] Pulmonary Artery Flow Using 4D Cardiac Magnetic Resonance Imaging
    Lua, S. B.
    Barrientos, P. Hall
    Ingram, J.
    Roditi, G.
    Brewis, M.
    Johnson, M.
    Church, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209