Double scattering and pencil beam scanning Monte Carlo workflows for proton therapy retrospective studies on radiation-induced toxicities

被引:1
|
作者
Leite, A. M. M. [1 ,2 ]
Bonfrate, A. [2 ]
Da Fonseca, A. [2 ]
Lansonneur, P. [2 ]
Alapetite, C. [2 ]
Mammar, H. [2 ]
De Marzi, L. [2 ,3 ]
机构
[1] PSL Res Univ, Univ Paris Saclay, Inst Curie, Inserm U 1021 CNRS UMR 3347, F-91898 Orsay, France
[2] PSL Res Univ, Inst Curie, Proton Therapy Ctr, Ctr Univ,Radiat Oncol Dept, Batiment 101, F-91898 Orsay, France
[3] Univ Paris Saclay, PSL Res Univ, Inst Curie, Inserm LITO, F-91898 Orsay, France
来源
CANCER RADIOTHERAPIE | 2023年 / 27卷 / 04期
关键词
Proton therapy; Monte Carlo simulations; Relative biological effectiveness; Radiation-induced toxicities; SIMULATIONS; MODEL;
D O I
10.1016/j.canrad.2023.02.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - Monte Carlo (MC) simulations can be used to accurately simulate dose and linear energy transfers (LET) distributions, thereby allowing for the calculation of the relative biological effectiveness (RBE) of protons. We present hereby the validation and implementation of a workflow for the Monte Carlo modelling of the double scattered and pencil beam scanning proton beamlines at our institution.Methods. - The TOPAS/Geant4 MC model of the clinical nozzle has been comprehensively validated against measurements. The validation also included a comparison between simulated clinical treatment plans for four representative patients and the clinical treatment planning system (TPS). Moreover, an in-house tool implemented in Python was tested to assess the variable RBE-weighted dose in proton plans, which was illustrated for a patient case with a developing radiation-induced toxicity. Results. - The simulated range and modulation width closely matches the measurements. Gamma-indexes (3%/3 mm 3D), which compare the TPS and MC computations, showed a passing rate superior to 98%. The calculated RBE-weighted dose presented a slight increase at the necrosis location, within the PTV margins. This indicates the need for reporting on the physical and biological effects of irradiation in high dose regions, especially at the healthy tissues and increased LET distributions location.Conclusion. - The results demonstrate that the Monte Carlo method can be used to independently validate a TPS calculation, and to estimate LET distributions. The features of the in-house tool can be used to correlate LET and RBE-weighted dose distributions with the incidence of radiation-induced toxicities following proton therapy treatments.& COPY; 2023 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:319 / 327
页数:9
相关论文
共 50 条
  • [1] Monte Carlo Dose Verification of Pencil Beam Scanning Proton Therapy
    Giantsoudi, D.
    Clasie, B.
    Grassberger, C.
    Dowdell, S.
    Depauw, N.
    Madden, T.
    Kooy, H.
    Paganetti, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams
    Charlwood, Frances C.
    Aitkenhead, Adam H.
    Mackay, Ranald I.
    MEDICAL PHYSICS, 2016, 43 (03) : 1462 - 1472
  • [3] Monte Carlo model of a gantry for proton pencil beam scanning
    Winterhalter, Carla
    Safai, Sairos
    Grassberger, Clemens
    Oxley, David
    Weber, Damien C.
    Lomax, Tony
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 837 - 837
  • [4] The Application of Cloud Computing in Pencil Beam Scanning Proton Therapy Monte Carlo Simulation
    Wang, Z.
    Gao, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 296 - 296
  • [5] Log file based Monte Carlo calculations for proton pencil beam scanning therapy
    Winterhalter, Carla
    Meier, Gabriel
    Oxley, David
    Weber, Damien C.
    Lomax, Antony J.
    Safai, Sairos
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03):
  • [6] Clinical validation of Monte Carlo dose calculation for pencil beam scanning proton therapy.
    Widesott, L.
    Lorentini, S.
    Fracchiolla, F.
    Farace, P.
    Schwarz, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S45 - S46
  • [7] Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy
    Huang, Sheng
    Kang, Minglei
    Souris, Kevin
    Ainsley, Christopher
    Solberg, Timothy D.
    McDonough, James E.
    Simone, Charles B.
    Lin, Liyong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 558 - 572
  • [8] An Automatic Beam Model Commissioning Method for Monte Carlo Simulations in Pencil-Beam Scanning Proton Therapy
    Qin, N.
    Shen, C.
    Tian, Z.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3335 - 3335
  • [9] Pitfalls in the beam modelling process of Monte Carlo calculations for proton pencil beam scanning
    Winterhalter, Carla
    Aitkenhead, Adam
    Oxley, David
    Richardson, Jenny
    Weber, Damien C.
    MacKay, Ranald, I
    Lomax, Antony J.
    Safai, Sairos
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107):
  • [10] Experimental Validation of the Monte Carlo Model of HYPERSCAN™ Pencil Beam Scanning System for Proton Beam Imaging and Radiation Treatment
    Huo, W.
    Zwart, T.
    Finley, C.
    Jee, K.
    Sharp, G.
    Rosenthal, S.
    Xu, X.
    Lu, H.
    MEDICAL PHYSICS, 2017, 44 (06) : 2872 - 2872