Evaluation of chemiluminescence immunoassay as a screening test for syphilis on blood donor samples

被引:2
|
作者
Gupta, Cherry [1 ]
Mittal, Kshitija [1 ]
Kaur, Ravneet [1 ]
Kaur, Jasbinder [2 ]
Sood, Tanvi [1 ]
Kaur, Gagandeep [1 ]
Kaur, Paramjit [1 ]
机构
[1] Govt Med Coll & Hosp, Dept Transfus Med, Chandigarh, India
[2] Govt Med Coll & Hosp, Dept Biochem, Chandigarh, India
关键词
Syphilis; Chemiluminescence immunoassay; Rapid plasma reagin; Treponema pallidum haemagglutination; Screening test; DIAGNOSIS;
D O I
10.1016/j.transci.2023.103836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective: Global re-emergence of syphilis among blood donors necessitates novel diagnostic and prevention approaches that encourage timely intervention. Thus, the present study was planned to evaluate the efficiency of Chemiluminescence immunoassay (CLIA) as a screening test for syphilis.Material and methods: This prospective cross-sectional observational study was conducted from October 2021 to September 2022. A total of 344 donors were enrolled by purposive sampling method, including additional 16 donors who were reactive by the Rapid plasma reagin test (RPR) during the study period. Data from three screening tests -RPR test, Treponema pallidum haemagglutination assay (TPHA) and CLIA for 360 blood donors were analysed. TPHA was considered the gold standard test.Results: Of the total 360 samples tested, 21 (5.8 %) were reactive by the RPR test. Of these 21 RPR reactive samples, 19 (90.5 %) were reactive by both TPHA and CLIA, while 2 (9.5 %) RPR reactive samples were non-reactive by both TPHA and CLIA. Of the remaining 339 RPR non-reactive samples, 1 (0.3 %) sample was reactive by both TPHA and CLIA, and 1 (0.3 %) was reactive by CLIA alone. CLIA was found to have sensitivity and specificity of 100 % and 99.7 % and positive predictive value (PPV) and negative predictive values (NPV) of 95.2 % and 100 % respectively, while it was 95 %, 99.4 %, 90 %, and 99.7 %, respectively, with the RPR test.Conclusion: CLIA was found to have a higher sensitivity, specificity, PPV and NPV than the RPR test. Thus, CLIA can be an acceptable alternative for syphilis screening in blood donors.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Evaluation of the blood progesterone concentration in the bitch measured by chemiluminescence immunoassay at the day of ovulation
    Schmicke, Marion
    Urhausen, Carola
    Wolf, Karola
    Schmidt, Susanne
    Guenzel-Apel, Anne-Rose
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2016, 44 (05): : 317 - 322
  • [42] Sensitivity and specificity of a syphilis rapid diagnostic test in blood donors' samples
    Arai, Carolina
    Lemos-Machado, Juliano Alves
    Aun, Marcelo Vivolo
    Bonet-Bub, Carolina
    Santos, Leandro Dinalli
    Miranda, Angelica Espinosa
    Avelino-Silva, Vivian I.
    BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2023, 27 (06):
  • [43] AN AUTOMATED CHEMILUMINESCENCE IMMUNOASSAY TEST FOR FREE TRIIODOTHYRONINE
    GAUMOND, B
    LINDSEY, K
    SANBORN, K
    MCGARY, D
    CORKERY, J
    HUNTRESS, MA
    LEOMENSAH, T
    PARSLOE, K
    JACKSON, T
    CLINICAL CHEMISTRY, 1995, 41 (06) : S57 - S57
  • [44] Washing-free chemiluminescence immunoassay for rapid detection of cardiac troponin Ⅰ in whole blood samples
    Huan Zhao
    Enben Su
    Li Huang
    Yunfeng Zai
    Yuan Liu
    Zhu Chen
    Song Li
    Lian Jin
    Yan Deng
    Nongyue He
    Chinese Chemical Letters, 2022, 33 (02) : 743 - 746
  • [45] Evaluation of a Syphilis Testing Algorithm Using a Treponemal Test for Screening
    Ozbek, O. Alpay
    Dogan, Yavuz
    MIKROBIYOLOJI BULTENI, 2011, 45 (01): : 93 - 103
  • [46] EVALUATION OF RPR CARD TEST FOR SYPHILIS SCREENING IN FIELD INVESTIGATIONS
    BROWN, WJ
    DONOHUE, JF
    PRICE, EV
    PUBLIC HEALTH REPORTS, 1964, 79 (06) : 496 - 500
  • [47] Evaluation of the Novel HISCL Chemiluminescence Enzyme Immunoassay for Laboratory Screening of Hepatitis C Virus
    Feng, Shu
    Wei, Bin
    Liu, Qianqian
    Wang, Tingting
    Li, Dongdong
    Rao, Chenli
    Tao, Chuanmin
    Wang, Lanlan
    CLINICAL AND VACCINE IMMUNOLOGY, 2016, 23 (07) : 652 - 654
  • [48] Evaluation of the clinical effectiveness of HIV antigen/antibody screening using a chemiluminescence microparticle immunoassay
    Cui, Chanjuan
    Liu, Ping
    Feng, Zhenru
    Xin, Ruolei
    Yan, Cunling
    Li, Zhiyan
    JOURNAL OF VIROLOGICAL METHODS, 2015, 214 : 33 - 36
  • [49] CHEMILUMINESCENCE IMMUNOASSAY OF CYCLOSPORINE IN WHOLE-BLOOD
    STABLER, TV
    SIEGEL, AL
    CLINICAL CHEMISTRY, 1990, 36 (06) : 906 - 908
  • [50] ROUTINE BLOOD-DONOR SCREENING FOR SYPHILIS CAN REVEAL RECENT INFECTION
    BARBARA, JAJ
    HEWITT, P
    ENRIGHT, S
    VOX SANGUINIS, 1993, 65 (03) : 243 - 243