Evaluation of chemiluminescence immunoassay as a screening test for syphilis on blood donor samples

被引:2
|
作者
Gupta, Cherry [1 ]
Mittal, Kshitija [1 ]
Kaur, Ravneet [1 ]
Kaur, Jasbinder [2 ]
Sood, Tanvi [1 ]
Kaur, Gagandeep [1 ]
Kaur, Paramjit [1 ]
机构
[1] Govt Med Coll & Hosp, Dept Transfus Med, Chandigarh, India
[2] Govt Med Coll & Hosp, Dept Biochem, Chandigarh, India
关键词
Syphilis; Chemiluminescence immunoassay; Rapid plasma reagin; Treponema pallidum haemagglutination; Screening test; DIAGNOSIS;
D O I
10.1016/j.transci.2023.103836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective: Global re-emergence of syphilis among blood donors necessitates novel diagnostic and prevention approaches that encourage timely intervention. Thus, the present study was planned to evaluate the efficiency of Chemiluminescence immunoassay (CLIA) as a screening test for syphilis.Material and methods: This prospective cross-sectional observational study was conducted from October 2021 to September 2022. A total of 344 donors were enrolled by purposive sampling method, including additional 16 donors who were reactive by the Rapid plasma reagin test (RPR) during the study period. Data from three screening tests -RPR test, Treponema pallidum haemagglutination assay (TPHA) and CLIA for 360 blood donors were analysed. TPHA was considered the gold standard test.Results: Of the total 360 samples tested, 21 (5.8 %) were reactive by the RPR test. Of these 21 RPR reactive samples, 19 (90.5 %) were reactive by both TPHA and CLIA, while 2 (9.5 %) RPR reactive samples were non-reactive by both TPHA and CLIA. Of the remaining 339 RPR non-reactive samples, 1 (0.3 %) sample was reactive by both TPHA and CLIA, and 1 (0.3 %) was reactive by CLIA alone. CLIA was found to have sensitivity and specificity of 100 % and 99.7 % and positive predictive value (PPV) and negative predictive values (NPV) of 95.2 % and 100 % respectively, while it was 95 %, 99.4 %, 90 %, and 99.7 %, respectively, with the RPR test.Conclusion: CLIA was found to have a higher sensitivity, specificity, PPV and NPV than the RPR test. Thus, CLIA can be an acceptable alternative for syphilis screening in blood donors.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Determination of a Sample-to-Cutoff Ratio to Predict True-Positivity in Blood Donor Samples Screened for Syphilis by a Chemiluminescent Immunoassay
    Akcakanat, I. Ebru
    Ozbek, Ozgen Alpay
    Dogan, Yavuz
    Abacioglu, Yusuf Hakan
    JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES, 2018, 2 (01): : 1 - 6
  • [22] Screening of syphilis in the Subsaharan African blood donor: Which strategy?
    Tagny, C. T.
    TRANSFUSION CLINIQUE ET BIOLOGIQUE, 2009, 16 (5-6) : 448 - 453
  • [23] Evaluation of a two test algorithm for donor screening for antibodies to htlv using a fully automated chemiluminescent immunoassay as the primary screening test.
    DiMarco, AA
    Schochetman, G
    Stewart, JL
    Dellefave, L
    Tate, C
    Stephens, JE
    Moreno, P
    TRANSFUSION, 1999, 39 (10) : 106S - 106S
  • [24] Screening for maternal and congenital syphilis with a chemiluminescence immunoassay in a South African private specialist healthcare sector setting
    Onyangunga, O. A.
    Moodley, K.
    Moodley, J.
    SAJOG-SOUTH AFRICAN JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2022, 28 (02): : 33 - 37
  • [25] AN AUTOMATED CHEMILUMINESCENCE IMMUNOASSAY TEST FOR DIGOXIN
    PETERSON, J
    NEVILL, J
    BLUESTEIN, B
    LARSEN, F
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1031 - 1031
  • [26] An automated chemiluminescence immunoassay test for digitoxin
    Peterson, J
    Sunshine, E
    Kilroy, J
    CLINICAL CHEMISTRY, 1996, 42 (06) : 466 - 466
  • [27] Detection of Zearalenone by Chemiluminescence Immunoassay in Corn Samples
    Wang, Yuan-Kai
    Zou, Qi
    Sun, Jian-He
    Wang, Heng-an
    Yan, Ya-Xian
    ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 1911 - 1914
  • [28] Evaluation of TPLA as an initial syphilis-screening test
    Murai, Ryosei
    Yamada, Koji
    Yanagihara, Nozomi
    Takahashi, Satoshi
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2017, 50 : S110 - S111
  • [29] CLINICAL EVALUATION OF A NEW SCREENING-TEST FOR SYPHILIS
    DYCKMAN, JD
    GATENBEIN, D
    WENDE, RD
    WILLIAMS, RP
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1978, 70 (06) : 918 - 921
  • [30] Evaluation of Automated Architect Syphilis TP as a Diagnostic Laboratory Screening Test for Syphilis
    Kim, Jeeyong
    Kim, Woo-Hyeun
    Cho, Chihyun
    Kim, Juyeon
    Kim, Ga-Yeong
    Nam, Myung-Hyun
    Kim, Jang Su
    Bae, Sook Young
    Cho, Yunjung
    KOREAN JOURNAL OF LABORATORY MEDICINE, 2008, 28 (06): : 475 - 482