Evaluation of chemiluminescence immunoassay as a screening test for syphilis on blood donor samples

被引:2
|
作者
Gupta, Cherry [1 ]
Mittal, Kshitija [1 ]
Kaur, Ravneet [1 ]
Kaur, Jasbinder [2 ]
Sood, Tanvi [1 ]
Kaur, Gagandeep [1 ]
Kaur, Paramjit [1 ]
机构
[1] Govt Med Coll & Hosp, Dept Transfus Med, Chandigarh, India
[2] Govt Med Coll & Hosp, Dept Biochem, Chandigarh, India
关键词
Syphilis; Chemiluminescence immunoassay; Rapid plasma reagin; Treponema pallidum haemagglutination; Screening test; DIAGNOSIS;
D O I
10.1016/j.transci.2023.103836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective: Global re-emergence of syphilis among blood donors necessitates novel diagnostic and prevention approaches that encourage timely intervention. Thus, the present study was planned to evaluate the efficiency of Chemiluminescence immunoassay (CLIA) as a screening test for syphilis.Material and methods: This prospective cross-sectional observational study was conducted from October 2021 to September 2022. A total of 344 donors were enrolled by purposive sampling method, including additional 16 donors who were reactive by the Rapid plasma reagin test (RPR) during the study period. Data from three screening tests -RPR test, Treponema pallidum haemagglutination assay (TPHA) and CLIA for 360 blood donors were analysed. TPHA was considered the gold standard test.Results: Of the total 360 samples tested, 21 (5.8 %) were reactive by the RPR test. Of these 21 RPR reactive samples, 19 (90.5 %) were reactive by both TPHA and CLIA, while 2 (9.5 %) RPR reactive samples were non-reactive by both TPHA and CLIA. Of the remaining 339 RPR non-reactive samples, 1 (0.3 %) sample was reactive by both TPHA and CLIA, and 1 (0.3 %) was reactive by CLIA alone. CLIA was found to have sensitivity and specificity of 100 % and 99.7 % and positive predictive value (PPV) and negative predictive values (NPV) of 95.2 % and 100 % respectively, while it was 95 %, 99.4 %, 90 %, and 99.7 %, respectively, with the RPR test.Conclusion: CLIA was found to have a higher sensitivity, specificity, PPV and NPV than the RPR test. Thus, CLIA can be an acceptable alternative for syphilis screening in blood donors.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Comparative evaluation of ADVIA Centaur® XP chemiluminescence system for screening of HBV, HCV, HIV and syphilis in Indian blood donors
    Arcot, Priyadarsini Jayachandran
    Pandey, Hem Chandra
    Coshic, Poonam
    Jain, Pankaj
    Kumar, Satendra
    Chakroborty, Sourit
    TRANSFUSION AND APHERESIS SCIENCE, 2022, 61 (02)
  • [32] Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis
    Ebel, A
    Bachelart, L
    Alonso, JM
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (02) : 358 - 361
  • [33] APPRAISAL OF ENZYME LINKED IMMUNOASSAY (ELISA) AND IMMUNOHEMAGGLUTINATION (IHA) CMV TEST METHODS FOR BLOOD-DONOR SCREENING
    KLINE, WE
    BOWMAN, RJ
    BALFOUR, HH
    EDELMAN, CK
    HOCKINSON, BJ
    TRANSFUSION, 1983, 23 (05) : 418 - 418
  • [34] A SCREENING-TEST FOR SYPHILIS WITH ACTIVE BLOOD-SERUM
    BEDNOVA, VN
    OVCHINNIKOV, NM
    MILONOVA, TI
    STOYANOVA, OA
    GOLBETS, II
    KRASNOPOLSKY, YM
    VESTNIK DERMATOLOGII I VENEROLOGII, 1985, (05) : 18 - 21
  • [35] The evaluation of the reverse algorithm for syphilis screening in blood donors
    Berkem, Rukiye
    Karakoc, Aye Esra
    REVISTA ROMANA DE MEDICINA DE LABORATOR, 2019, 27 (04): : 383 - 388
  • [36] IMPROVEMENT OF SYPHILIS SCREENING IN BLOOD-DONORS BY TPHA TEST
    KLUGE, A
    BORZANI, E
    ROELCKE, D
    BLUT, 1980, 40 (02): : 117 - 122
  • [37] EVALUATION OF THE DCL SYPHILIS-G ENZYME-IMMUNOASSAY TEST KIT FOR THE SEROLOGIC DIAGNOSIS OF SYPHILIS
    NAYAR, R
    CAMPOS, JM
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 99 (03) : 282 - 285
  • [38] HTLV screening of blood donors using chemiluminescence immunoassay in three major provincial blood centers of China
    Junpeng Zhao
    Feixue Zhao
    Wei Han
    Xiaoxuan Xu
    Lilin Wang
    Ran Li
    Tong Li
    Linfeng Wu
    Dandan Du
    Xuezhen Zeng
    Xiujuan Cui
    Yunlong Chen
    Jinfeng Zeng
    Lunan Wang
    BMC Infectious Diseases, 20
  • [39] HTLV screening of blood donors using chemiluminescence immunoassay in three major provincial blood centers of China
    Zhao, Junpeng
    Zhao, Feixue
    Han, Wei
    Xu, Xiaoxuan
    Wang, Lilin
    Li, Ran
    Li, Tong
    Wu, Linfeng
    Du, Dandan
    Zeng, Xuezhen
    Cui, Xiujuan
    Chen, Yunlong
    Zeng, Jinfeng
    Wang, Lunan
    BMC INFECTIOUS DISEASES, 2020, 20 (01)
  • [40] An automated chemiluminescence immunoassay test for urinary cortisol
    Reamer, CR
    Curley, J
    MacDonald, L
    Parsons, J
    Connolly, P
    Barbarakis, T
    Natoli, E
    Kilroy, J
    CLINICAL CHEMISTRY, 1996, 42 (06) : 344 - 344