Evaluation of chemiluminescence immunoassay as a screening test for syphilis on blood donor samples

被引:2
|
作者
Gupta, Cherry [1 ]
Mittal, Kshitija [1 ]
Kaur, Ravneet [1 ]
Kaur, Jasbinder [2 ]
Sood, Tanvi [1 ]
Kaur, Gagandeep [1 ]
Kaur, Paramjit [1 ]
机构
[1] Govt Med Coll & Hosp, Dept Transfus Med, Chandigarh, India
[2] Govt Med Coll & Hosp, Dept Biochem, Chandigarh, India
关键词
Syphilis; Chemiluminescence immunoassay; Rapid plasma reagin; Treponema pallidum haemagglutination; Screening test; DIAGNOSIS;
D O I
10.1016/j.transci.2023.103836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective: Global re-emergence of syphilis among blood donors necessitates novel diagnostic and prevention approaches that encourage timely intervention. Thus, the present study was planned to evaluate the efficiency of Chemiluminescence immunoassay (CLIA) as a screening test for syphilis.Material and methods: This prospective cross-sectional observational study was conducted from October 2021 to September 2022. A total of 344 donors were enrolled by purposive sampling method, including additional 16 donors who were reactive by the Rapid plasma reagin test (RPR) during the study period. Data from three screening tests -RPR test, Treponema pallidum haemagglutination assay (TPHA) and CLIA for 360 blood donors were analysed. TPHA was considered the gold standard test.Results: Of the total 360 samples tested, 21 (5.8 %) were reactive by the RPR test. Of these 21 RPR reactive samples, 19 (90.5 %) were reactive by both TPHA and CLIA, while 2 (9.5 %) RPR reactive samples were non-reactive by both TPHA and CLIA. Of the remaining 339 RPR non-reactive samples, 1 (0.3 %) sample was reactive by both TPHA and CLIA, and 1 (0.3 %) was reactive by CLIA alone. CLIA was found to have sensitivity and specificity of 100 % and 99.7 % and positive predictive value (PPV) and negative predictive values (NPV) of 95.2 % and 100 % respectively, while it was 95 %, 99.4 %, 90 %, and 99.7 %, respectively, with the RPR test.Conclusion: CLIA was found to have a higher sensitivity, specificity, PPV and NPV than the RPR test. Thus, CLIA can be an acceptable alternative for syphilis screening in blood donors.
引用
收藏
页数:4
相关论文
共 50 条
  • [2] Evaluation of a Particle Gel Immunoassay as a Screening Test for Syphilis
    S. Borelli
    A. Monn
    J. Meyer
    U. Berger
    H. P. Honegger
    St. Lautenschlager
    Infection, 2009, 37 : 26 - 28
  • [3] Evaluation of a Particle Gel Immunoassay as a Screening Test for Syphilis
    Borelli, S.
    Monn, A.
    Meyer, J.
    Berger, U.
    Honegger, H. P.
    Lautenschlager, St.
    INFECTION, 2009, 37 (01) : 26 - 28
  • [4] Evaluation of the Boson Chemiluminescence Immunoassay as a First-Line Screening Test in the ECDC Algorithm for Syphilis Serodiagnosis in a Population with a High Prevalence of Syphilis
    Qiu, Xin-Hui
    Zhang, Ya-Feng
    Chen, Yu-Yan
    Zhang, Qiao
    Chen, Fu-Yi
    Liu, Long
    Fan, Jin-Yi
    Gao, Kun
    Zhu, Xiao-Zhen
    Zheng, Wei-Hong
    Zhang, Hui-Lin
    Lin, Li-Rong
    Liu, Li-Li
    Tong, Man-Li
    Zhang, Chang-Gong
    Niu, Jian-Jun
    Yang, Tian-Ci
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (04) : 1371 - 1374
  • [5] EVALUATION OF A NEW CHEMILUMINESCENCE IMMUNOASSAY FOR DIAGNOSIS OF SYPHILIS
    Mo, Xiaohui
    Jin, Yuelan
    Yang, Yang
    Hu, Weizhong
    Gu, Weiming
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 (02) : 66 - 69
  • [6] Evaluation of a new chemiluminescence immunoassay for diagnosis of syphilis
    Xiaohui Mo
    Yuelan Jin
    Yang Yang
    Weizhong Hu
    Weiming Gu
    European Journal of Medical Research, 15
  • [7] Evaluation of the LIAISON chemiluminescence immunoassay for diagnosis of syphilis
    Knight, Carrie S.
    Crum, Mary A.
    Hardy, Robert W.
    CLINICAL AND VACCINE IMMUNOLOGY, 2007, 14 (06) : 710 - 713
  • [8] Evaluation of the Vitros Syphilis TPA Chemiluminescence Immunoassay as a First-Line Method for Reverse Syphilis Screening
    Gonzalez, Victoria
    Fernandez, Gema
    Dopico, Eva
    Margall, Nuria
    Esperalba, Juliana
    Munoz, Carme
    Castro, Elisabeth
    Sulleiro, Elena
    Matas, Lurdes
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (04) : 1361 - 1364
  • [9] Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
    Chuanmin Tao
    Xiaoke Hao
    Wei Xu
    Jie Zhang
    Shiyang Pan
    Zhihua Tao
    Xiaofei Li
    Junmei Chen
    Bingchang Zhang
    Yurong Qiu
    Yanan Wu
    Qishui Ou
    Xianzhang Huang
    Lanlan Wang
    Scientific Reports, 7
  • [10] Evaluation of the Elecsys syphilis immunoassay for routine screening of serum samples in China
    Tao, Chuanmin
    Hao, Xiaoke
    Xu, Wei
    Zhang, Jie
    Pan, Shiyang
    Tao, Zhihua
    Li, Xiaofei
    Chen, Junmei
    Zhang, Bingchang
    Qiu, Yurong
    Wu, Yanan
    Ou, Qishui
    Huang, Xianzhang
    Wang, Lanlan
    SCIENTIFIC REPORTS, 2017, 7