Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates

被引:4
|
作者
Alrehily, Faisal A. [1 ]
Alqahtani, Khalid S. [1 ]
Aljohani, Marwan H. [1 ]
Alharbi, Nawaf S. [1 ]
Alharbi, Reyan M. [2 ]
Abdulaal, Osamah M. [1 ]
Alshamrani, Abdullah F. [1 ]
Alsaedi, Abdulrahman S. [3 ]
Al-Murshedi, Sadeq H. [4 ,5 ]
Alhazmi, Fahad H. [1 ]
机构
[1] Taibah Univ, Dept Diag Radiol Technol, Coll Appl Med Sci, Al Madinah Al Munawwarah, Saudi Arabia
[2] King Salman bin Abdulaziz Med City, Dept Radiol, Riyadh, Saudi Arabia
[3] King Fahad Gen Hosp, Dept Nucl Med, Al Madinah Al Munawwarah, Saudi Arabia
[4] AL Zahraa Univ Women, Coll Hlth & Med Technol, Dept Radiol Tech, Karbala, Iraq
[5] Univ Babylon, Coll Educ Pure Sci, Phys Dept, Babylon, Iraq
关键词
CT; DRL; CTDIvol; DLP; SSDE; effective diameter; CT; RADIATION; WEIGHT; CANCER; CHEST;
D O I
10.15537/smj.2023.44.8.20230230
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To establish local DRL (LDRL) for computed tomography (CT) examinations based on size-specific dose estimates (SSDEs), which consider patient size. The concept of diagnostic reference level (DRL) was introduced to limit patient exposure to unnecessary radiation. However, traditional DRL values do not consider patient size. Methods: Following institutional committee approval, data were collected from CT examinations of adult patients at Madinah General Hospital, Al Madinah Al Munawwarah, Saudi Arabia from January to March 2023. The SSDE was calculated for each patient using the effective diameter (D-eff). Results: The LDRLs of the brain, cervical spine, chest, thoracic spine and kidneys, ureters, and bladder (KUB) examinations were 118 mGy, 12 mGy, 8 mGy, 17 mGy, and 7 mGy, respectively. A strong correlation was observed between SSDEs and the volume computed tomography dose index (CTDIvol) for all examinations except chest scans (p<0.05). Size-specific dose estimates were higher than the CTDIvol, with a greater difference for patients with smaller Deff (p<0.05). Conclusion: The established LDRL was within the international DRL. The use of SSDE has the potential to provide more accurate and relevant data for radiation safety practices; however, widespread adoption of SSDE in new CT scanners is necessary for promoting consistency and standardization methodologies.
引用
收藏
页码:761 / 766
页数:6
相关论文
共 50 条
  • [1] Local Diagnostic Reference Levels and Size-Specific Patient Dose in Computed Tomography at a Greek Hospital
    Stasinou, D.
    Zoiopoulou, V.
    Antonakos, J.
    Argentos, S.
    Efstathopoulos, E.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates
    Boos, Johannes
    Thomas, Christoph
    Appel, Elisabeth
    Klosterkemper, Yan
    Schleich, Christoph
    Aissa, Joel
    Bethge, Oliver Th
    Antoch, Gerald
    Kroepil, Patric
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 536 - 548
  • [3] Development of size-specific dose estimates for common computed tomography examinations: a study in Ghana
    Ohene-Botwe, Benard
    Anim-Sampong, Samuel
    Nkansah, Josephine
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (01)
  • [4] Size-Specific Dose Estimates in Fetal Computed Tomography
    Kobayashi, Masanao
    Nishihara, Yusei
    Haba, Tomonobu
    Matsunaga, Yuta
    Minami, Kazuyuki
    Asada, Yasuki
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 339 - 348
  • [5] Size-Specific Dose Estimates for Thoracic and Abdominal Computed Tomography Examinations at Two Moroccan Hospitals
    El Mansouri, M'hamed
    Choukri, Abdelmajid
    Semghouli, Slimane
    Talbi, Mohammed
    Eddaoui, Khalida
    Saga, Zouhir
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1648 - 1653
  • [6] Size-Specific Dose Estimates for Thoracic and Abdominal Computed Tomography Examinations at Two Moroccan Hospitals
    M’hamed El Mansouri
    Abdelmajid Choukri
    Slimane Semghouli
    Mohammed Talbi
    Khalida Eddaoui
    Zouhir Saga
    Journal of Digital Imaging, 2022, 35 : 1648 - 1653
  • [7] Estimation of radiation dose associated with bone SPECT/CT and establishing local diagnostic reference levels using size-specific dose estimate
    Alrehily, Faisal
    Alshamrani, Abdullah F.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (01)
  • [8] Determination of radiation dose during computed tomography examinations in southern Saudi Arabian hospitals using size-specific dose estimates
    Saeed, Mohammed K.
    Asiri, Abdullah Ali M.
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 15 (02) : 147 - 158
  • [9] Using a Somatosensory Controller to Assess Body Size for Size-Specific Dose Estimates in Computed Tomography
    Wu, Jay
    Han, Ruo-Ping
    Liu, Yan-Lin
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [10] Development of size-specific institutional diagnostic reference levels for computed tomography protocols in neck imaging
    Steuwe A.
    Thomas C.
    Kraus B.
    Bethge O.T.
    Aissa J.
    Klosterkemper Y.
    Antoch G.
    Boos J.
    Journal of Radiological Protection, 2020, 40 (01) : 68 - 82