Development of size-specific dose estimates for common computed tomography examinations: a study in Ghana

被引:1
|
作者
Ohene-Botwe, Benard [1 ,2 ]
Anim-Sampong, Samuel [2 ]
Nkansah, Josephine [2 ]
机构
[1] City Univ London, Sch Hlth & Psychol Sci, Dept Midwifery & Radiog, Northampton Sq, London EC1V 0HB, England
[2] Univ Ghana, Dept Radiog, Box KB 143, Accra, Ghana
关键词
computed tomography; dose index; size-specific dose estimate; antero-posterior diameter; lateral diameter; effective diameter; CT;
D O I
10.1088/1361-6498/acb5aa
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study determined the size-specific dose estimate (SSDE) of computed tomography (CT) examinations and derived mathematical expressions for dose output estimation and optimization in a teaching hospital in Ghana. Demographic and scanner output indices, including CT dose index (CTDIvol) and dose length product for adult head, chest and abdominopelvic (ABP) CT examinations carried out at the hospital from 2018 to 2020, were retrieved from the picture archiving and communication system of the CT scanner machine. Other indices such as the antero-posterior diameter (D (AP)), lateral diameter (D (L)) and diagonal diameter (D (dia)) of the patients' bodies were measured on the mid-slice axial image using a digital caliper. The effective diameter (D (eff)) was then calculated as the square root of the product of the D (AP) and D (L). The SSDEs were calculated as the product of the CTDIvol and the size-specific conversion factors obtained from Report 204 of the American Association of Physicists in Medicine. Regression analyses were performed to find the relationship between SSDE and the various parameters to derive mathematical equations for the dose estimations. There were more female samples (n= 468, 56.3%) than male samples (n = 364, 43.7%) for each CT procedure. The SSDEs and size-specific diagnostic reference levels (SSDRLs) were: head (83.9 mGy; 86.9 mGy), chest (8.1 mGy; 8.7 mGy) and ABP (8.4 mGy; 9.2 mGy). The variations between CTDIvol and SSDEs for head (2.50%), chest (25.9%), and ABP (26.2%) showed an underestimation of radiation dose to patients, especially in chest and ABP examinations, if CTDIvol is used to report patient doses. The SSDEs of the chest and ABP CT examinations showed linear correlations with the CTDIvol. The estimated values could be used to optimize radiation doses in the CT facility. The SSDE and SSDRLs for head, chest and ABP CT examinations have been developed at a teaching hospital in Ghana. The SSDEs of chest and ABP examinations showed linear correlations with the CTDIvol and hence can be calculated using the mathematically derived equations in the study.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Size-Specific Dose Estimates in Fetal Computed Tomography
    Kobayashi, Masanao
    Nishihara, Yusei
    Haba, Tomonobu
    Matsunaga, Yuta
    Minami, Kazuyuki
    Asada, Yasuki
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 339 - 348
  • [2] Size-Specific Dose Estimates for Thoracic and Abdominal Computed Tomography Examinations at Two Moroccan Hospitals
    El Mansouri, M'hamed
    Choukri, Abdelmajid
    Semghouli, Slimane
    Talbi, Mohammed
    Eddaoui, Khalida
    Saga, Zouhir
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1648 - 1653
  • [3] Size-Specific Dose Estimates for Thoracic and Abdominal Computed Tomography Examinations at Two Moroccan Hospitals
    M’hamed El Mansouri
    Abdelmajid Choukri
    Slimane Semghouli
    Mohammed Talbi
    Khalida Eddaoui
    Zouhir Saga
    Journal of Digital Imaging, 2022, 35 : 1648 - 1653
  • [4] Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates
    Alrehily, Faisal A.
    Alqahtani, Khalid S.
    Aljohani, Marwan H.
    Alharbi, Nawaf S.
    Alharbi, Reyan M.
    Abdulaal, Osamah M.
    Alshamrani, Abdullah F.
    Alsaedi, Abdulrahman S.
    Al-Murshedi, Sadeq H.
    Alhazmi, Fahad H.
    SAUDI MEDICAL JOURNAL, 2023, 44 (08) : 761 - 766
  • [5] Size-specific dose estimates: Localizer or transverse abdominal computed tomography images?
    Pourjabbar, Sarvenaz
    Singh, Sarabjeet
    Padole, Atul
    Saini, Akshay
    Blake, Michael A.
    Kalra, Mannudeep K.
    WORLD JOURNAL OF RADIOLOGY, 2014, 6 (05): : 210 - 217
  • [6] Determination of radiation dose during computed tomography examinations in southern Saudi Arabian hospitals using size-specific dose estimates
    Saeed, Mohammed K.
    Asiri, Abdullah Ali M.
    MAEJO INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 15 (02) : 147 - 158
  • [7] Determining Size-Specific Dose Estimates for Head CT Examinations
    Hardy, A.
    Bostani, M.
    Zankl, M.
    McCollough, C.
    Cagnon, C.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3314 - 3315
  • [8] Using a Somatosensory Controller to Assess Body Size for Size-Specific Dose Estimates in Computed Tomography
    Wu, Jay
    Han, Ruo-Ping
    Liu, Yan-Lin
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [9] Multivariate Analysis of Effective Dose and Size-Specific Dose Estimates for Thorax and Abdominal Computed Tomography
    Shah, Mudasir Ashraf
    Ahmad, Mehtab
    Khalid, Saifullah
    Qaseem, Syed M. Danish
    Siddiqui, Shaista
    Talib, Sayema
    Rather, Sajad Ahmed
    Firdous, Arfat
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (02) : 210 - 218
  • [10] Size-specific dose estimates (SSDEs) for computed tomography and influencing factors on it: a systematic review
    Satharasinghe, D. M.
    Jeyasugiththan, J.
    Wanninayake, W. M. N. M. B.
    Pallewatte, A. S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : R108 - R124