Development of size-specific institutional diagnostic reference levels for computed tomography protocols in neck imaging

被引:3
|
作者
Steuwe A. [1 ]
Thomas C. [1 ]
Kraus B. [1 ]
Bethge O.T. [1 ]
Aissa J. [1 ]
Klosterkemper Y. [1 ]
Antoch G. [1 ]
Boos J. [1 ]
机构
[1] University Düsseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Düsseldorf
关键词
computed tomography; diagnostic reference levels; neck CT imaging;
D O I
10.1088/1361-6498/ab4d00
中图分类号
学科分类号
摘要
Purpose: To develop size-specific institutional diagnostic reference levels (DRLs) for computed tomography (CT) protocols used in neck CT imaging (cervical spine CT, cervical CT angiography (CTA) and cervical staging CT) and to compare institutional to national DRLs. Materials and methods: Cervical CT examinations (spine, n = 609; CTA, n = 505 and staging CT, n = 184) performed between 01/2016 and 06/2017 were included in this retrospective study. For each region and examination, the volumetric CT dose index (CTDIvol) and dose-length product (DLP) were determined and binned into size bins according to patient water-equivalent diameter (dw). Linear regression analysis was performed to calculate size-specific institutional DRLs for CTDIvol and DLP, applying the 75th percentile as the upper limit for institutional DRLs. The mean institutional CTDIvol and DLP were compared to national DRLs (CTDIvol 20 mGy for cervical spine CT (DLP 300 mGycm) and cervical CTA (DLP 600 mGycm), and CTDIvol 15 mGy for cervical staging CT (DLP 330 mGycm)). Results: The mean CTDIvol and DLP (standard deviation) were 15.2 4.1 mGy and 181.5 88.3 mGycm for cervical spine CT; 8.1 4.3 mGy and 280.2 164.3 mGycm for cervical CTA; 8.6 1.9 mGy and 162.8 85.0 mGycm for cervical staging CT. For all CT protocols, there was a linear increase in CTDIvol and DLP with increasing dw. For the CTDIvol, size-specific institutional DRLs increased with dw from 14 to 29 mGy for cervical spine CT, from 5 to 17 mGy for cervical CTA and from 8 to 13 mGy for cervical staging CT. For the DLP, size-specific institutional DRLs increased with dw from 130 to 510 mGycm for cervical spine CT, from 140 to 640 mGycm for cervical CTA and from 140 to 320 mGycm for cervical staging CT. Institutional DRLs were lower than national DRLs by 81% and 67% for cervical spine CT (dw = 17.8 cm), 43% and 51% for cervical CTA (dw = 19.5 cm) and 59% and 53% for cervical staging CT (dw = 18.8 cm) for CTDIvol and DLP, respectively. Conclusion: Size-specific institutional DRLs were generated for neck CT examinations. The mean institutional CTDIvol and DLP values were well below national DRLs. © 2019 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved..
引用
收藏
页码:68 / 82
页数:14
相关论文
共 50 条
  • [1] Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates
    Boos, Johannes
    Thomas, Christoph
    Appel, Elisabeth
    Klosterkemper, Yan
    Schleich, Christoph
    Aissa, Joel
    Bethge, Oliver Th
    Antoch, Gerald
    Kroepil, Patric
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 536 - 548
  • [2] Local Diagnostic Reference Levels and Size-Specific Patient Dose in Computed Tomography at a Greek Hospital
    Stasinou, D.
    Zoiopoulou, V.
    Antonakos, J.
    Argentos, S.
    Efstathopoulos, E.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [3] Implementation of Institutional Size-Specific Diagnostic Reference Levels for CT Angiography
    Klosterkemper, Yan
    Thomas, Christoph
    Bethge, Oliver T.
    Appel, Elisabeth
    Aissa, Joel
    Boeven, Judith
    Antoch, Gerald
    Boos, Johannes
    ACADEMIC RADIOLOGY, 2019, 26 (12) : 1661 - 1667
  • [4] Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates
    Alrehily, Faisal A.
    Alqahtani, Khalid S.
    Aljohani, Marwan H.
    Alharbi, Nawaf S.
    Alharbi, Reyan M.
    Abdulaal, Osamah M.
    Alshamrani, Abdullah F.
    Alsaedi, Abdulrahman S.
    Al-Murshedi, Sadeq H.
    Alhazmi, Fahad H.
    SAUDI MEDICAL JOURNAL, 2023, 44 (08) : 761 - 766
  • [5] Size-Specific Dose Estimates in Fetal Computed Tomography
    Kobayashi, Masanao
    Nishihara, Yusei
    Haba, Tomonobu
    Matsunaga, Yuta
    Minami, Kazuyuki
    Asada, Yasuki
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 339 - 348
  • [6] Development of size-specific dose estimates for common computed tomography examinations: a study in Ghana
    Ohene-Botwe, Benard
    Anim-Sampong, Samuel
    Nkansah, Josephine
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (01)
  • [7] Diagnostic reference levels for chest computed tomography in children as a function of patient size
    Bos, Denise
    Zensen, Sebastian
    Opitz, Marcel K.
    Haubold, Johannes
    Nassenstein, Kai
    Kinner, Sonja
    Schweiger, Bernd
    Forsting, Michael
    Wetter, Axel
    Guberina, Nika
    PEDIATRIC RADIOLOGY, 2022, 52 (08) : 1446 - 1455
  • [8] Diagnostic reference levels for paediatric computed tomography
    Vawda, Zakariya
    Pitcher, Richard
    Akudugu, John
    Groenewald, Willem
    SA JOURNAL OF RADIOLOGY, 2015, 19 (02):
  • [9] A Review of Diagnostic Reference Levels in Computed Tomography
    Dawd, Jemal Edris
    Ozsahin, Dilber Uzun
    Ozsahin, Ilker
    CURRENT MEDICAL IMAGING, 2022, 18 (06) : 623 - 632
  • [10] Diagnostic reference levels for chest computed tomography in children as a function of patient size
    Denise Bos
    Sebastian Zensen
    Marcel K. Opitz
    Johannes Haubold
    Kai Nassenstein
    Sonja Kinner
    Bernd Schweiger
    Michael Forsting
    Axel Wetter
    Nika Guberina
    Pediatric Radiology, 2022, 52 : 1446 - 1455