Development of size-specific institutional diagnostic reference levels for computed tomography protocols in neck imaging

被引:3
|
作者
Steuwe A. [1 ]
Thomas C. [1 ]
Kraus B. [1 ]
Bethge O.T. [1 ]
Aissa J. [1 ]
Klosterkemper Y. [1 ]
Antoch G. [1 ]
Boos J. [1 ]
机构
[1] University Düsseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Düsseldorf
关键词
computed tomography; diagnostic reference levels; neck CT imaging;
D O I
10.1088/1361-6498/ab4d00
中图分类号
学科分类号
摘要
Purpose: To develop size-specific institutional diagnostic reference levels (DRLs) for computed tomography (CT) protocols used in neck CT imaging (cervical spine CT, cervical CT angiography (CTA) and cervical staging CT) and to compare institutional to national DRLs. Materials and methods: Cervical CT examinations (spine, n = 609; CTA, n = 505 and staging CT, n = 184) performed between 01/2016 and 06/2017 were included in this retrospective study. For each region and examination, the volumetric CT dose index (CTDIvol) and dose-length product (DLP) were determined and binned into size bins according to patient water-equivalent diameter (dw). Linear regression analysis was performed to calculate size-specific institutional DRLs for CTDIvol and DLP, applying the 75th percentile as the upper limit for institutional DRLs. The mean institutional CTDIvol and DLP were compared to national DRLs (CTDIvol 20 mGy for cervical spine CT (DLP 300 mGycm) and cervical CTA (DLP 600 mGycm), and CTDIvol 15 mGy for cervical staging CT (DLP 330 mGycm)). Results: The mean CTDIvol and DLP (standard deviation) were 15.2 4.1 mGy and 181.5 88.3 mGycm for cervical spine CT; 8.1 4.3 mGy and 280.2 164.3 mGycm for cervical CTA; 8.6 1.9 mGy and 162.8 85.0 mGycm for cervical staging CT. For all CT protocols, there was a linear increase in CTDIvol and DLP with increasing dw. For the CTDIvol, size-specific institutional DRLs increased with dw from 14 to 29 mGy for cervical spine CT, from 5 to 17 mGy for cervical CTA and from 8 to 13 mGy for cervical staging CT. For the DLP, size-specific institutional DRLs increased with dw from 130 to 510 mGycm for cervical spine CT, from 140 to 640 mGycm for cervical CTA and from 140 to 320 mGycm for cervical staging CT. Institutional DRLs were lower than national DRLs by 81% and 67% for cervical spine CT (dw = 17.8 cm), 43% and 51% for cervical CTA (dw = 19.5 cm) and 59% and 53% for cervical staging CT (dw = 18.8 cm) for CTDIvol and DLP, respectively. Conclusion: Size-specific institutional DRLs were generated for neck CT examinations. The mean institutional CTDIvol and DLP values were well below national DRLs. © 2019 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved..
引用
收藏
页码:68 / 82
页数:14
相关论文
共 50 条
  • [31] ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY
    Boos, Johannes
    Kroepil, Patric
    Bethge, Oliver Th.
    Aissa, Joel
    Schleich, Christoph
    Sawicki, Lino Morris
    Heinzler, Niklas
    Antoch, Gerald
    Thomas, Christoph
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 8 - 19
  • [32] Size-specific dose estimates (SSDEs) for computed tomography and influencing factors on it: a systematic review
    Satharasinghe, D. M.
    Jeyasugiththan, J.
    Wanninayake, W. M. N. M. B.
    Pallewatte, A. S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : R108 - R124
  • [33] Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Hanaoka, Shinsuke
    Matsubara, Kosuke
    Takata, Tadanori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 246 - 251
  • [34] Local Diagnostic Reference Levels for Adult Computed Tomography Urography Exams
    Husremovic, Faruk
    Muharemovic, Orhan
    Dedovic, Edis
    Efendic, Alma
    Musanovic, Jasmin
    Omerovic, Rifat
    Osmanovic, Hedim
    Busuladzic, Mustafa
    DIAGNOSTICS, 2024, 14 (06)
  • [35] Establishing Local Diagnostic Reference Levels for Head Computed Tomography Examinations
    Modlinska, Sandra
    Rojek, Marcin
    Bielowka, Michal
    Kufel, Jakub
    BIOMEDICINES, 2024, 12 (11)
  • [36] Paediatric computed tomography diagnostic reference levels in Africa: A systematic review
    Gyan, Emmanuel
    Subaar, Christiana
    Edusei, George
    Antwi Nyarko, Linda
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025, 72 (01) : 139 - 147
  • [37] Establishing national paediatric computed tomography diagnostic reference levels in Ghana
    Shirazu, Issahaku
    Sackey, Theophilus A.
    Edziah, Raymond
    Boateng, Yaw Mensah
    Schandorf, Cyril.
    HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1187 - 1198
  • [38] Establishing local diagnostic reference levels for adult computed tomography in Morocco
    El Mansouri, M.
    Talbi, M.
    Choukri, A.
    Nhila, O.
    Aabid, M.
    RADIOPROTECTION, 2022, 57 (01) : 61 - 66
  • [39] Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt
    Salama, Dina Husseiny
    Vassileva, Jenia
    Mahdaly, Gamal
    Shawki, Mona
    Salama, Ahmad
    Gilley, Debbie
    Rehani, Madan Mohan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 16 - 24
  • [40] 2021 NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY IN EGYPT
    Abdou, Sayed E.
    Salama, Dina H.
    Ahmad, Khaled A.
    Sallam, Abdelsattar M.
    El-Sayed, El-Sayed Mahmoud
    Talaat, M. S.
    El-Farrash, Rania A.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (07) : 423 - 433