Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt

被引:62
|
作者
Salama, Dina Husseiny [1 ]
Vassileva, Jenia [2 ]
Mahdaly, Gamal [3 ]
Shawki, Mona [4 ]
Salama, Ahmad [5 ]
Gilley, Debbie [2 ]
Rehani, Madan Mohan [6 ,7 ]
机构
[1] Egyptian Atom Energy Author, Cairo, Egypt
[2] IAEA, Vienna, Austria
[3] Experta Med, Cairo, Egypt
[4] Alexandria Fac Med, Alexandria, Egypt
[5] Ain Shams Fac Med, Cairo, Egypt
[6] Massachusetts Gen Hosp, Boston, MA 02114 USA
[7] Harvard Med Sch, Boston, MA USA
关键词
DRLs in Egypt; Computed tomography (CT) DRLs; Patient doses African country; National dose survey Egypt; CT EXAMINATIONS;
D O I
10.1016/j.ejmp.2017.05.050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To establish national diagnostic reference levels (DRLs) in Egypt for computed tomography (CT) examinations of adults and identify the potential for optimization. Methods: Data from 3762 individual patient's undergoing CT scans of head, chest (high resolution), abdomen, abdomen-pelvis, chest-abdomen-pelvis and CT angiography (aorta and both lower limbs) examinations in 50 CT facilities were collected. This represents 20% of facilities in the country and all of the 27 Governorates. Results were compared with DRLs of UK, USA, Canada, Japan, Australia and France. Results: The Egyptian DRLs for CTDIvol in mGy are for head: 30, chest (high resolution): 22, abdomen (liver metastasis): 31, abdomen-pelvis: 31, chest-abdomen-pelvis: 33 and CT angiography (aorta and lower limbs): 37. The corresponding DRLs for DLP in mGy. cm are 1360, 420, 1425, 1325, 1320 and 1320. For head CT, the Egyptian DRL for CTDIvol is 2-3 times lower than the DRLs from other countries. However, the DRL in terms of DLP is in the same range or higher as compared to others. The Egyptian DRL for chest CT (high resolution) is similar to others for DLP but higher for CTDIvol. For abdomen and abdomen-pelvis DRLs for CTDIvol are higher than others. For DLP, the DRLs for abdomen are higher than DRL in UK and lower than those in Japan, while for abdomen-pelvis they are higher than other countries. Conclusion: Despite lower DRLs for CTDIvol, an important consistent problem appears to be higher scan range as DRLs for DLP are higher. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 50 条
  • [1] Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
    Radaideh, Khaldoon
    Al-Radaideh, Ali
    Ramli, Ramzun Maizan
    Saleh, Abdallah
    Alshayeb, Rasha
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 26 - 34
  • [2] Establishing national paediatric computed tomography diagnostic reference levels in Ghana
    Shirazu, Issahaku
    Sackey, Theophilus A.
    Edziah, Raymond
    Boateng, Yaw Mensah
    Schandorf, Cyril.
    [J]. HEALTH AND TECHNOLOGY, 2024,
  • [3] 2021 NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY IN EGYPT
    Abdou, Sayed E.
    Salama, Dina H.
    Ahmad, Khaled A.
    Sallam, Abdelsattar M.
    El-Sayed, El-Sayed Mahmoud
    Talaat, M. S.
    El-Farrash, Rania A.
    Vassileva, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2022, 198 (07) : 423 - 433
  • [4] Establishment of national diagnostic reference levels (DRLs) for radiotherapy localisation computer tomography of the head and neck
    Clerkin, Celine
    Brennan, Sinead
    Mullaney, Laura M.
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (05) : 407 - 412
  • [5] Establishing local diagnostic reference levels for adult computed tomography in Morocco
    El Mansouri, M.
    Talbi, M.
    Choukri, A.
    Nhila, O.
    Aabid, M.
    [J]. RADIOPROTECTION, 2022, 57 (01) : 61 - 66
  • [6] Canadian Computed Tomography Survey: National Diagnostic Reference Levels
    Wardlaw, Graeme M.
    Martel, Narine
    [J]. MEDICAL PHYSICS, 2016, 43 (08) : 4932 - 4933
  • [7] ESTABLISHING DIAGNOSTIC REFERENCE LEVELS FOR CARDIAC COMPUTED TOMOGRAPHY ANGIOGRAPHY IN SAUDI ARABIA
    Alhailiy, Ali B.
    Kench, Peter L.
    McEntee, Mark F.
    Brennan, Patrick C.
    Ryan, Elaine A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 181 (02) : 129 - 134
  • [8] Diagnostic reference levels (DRLs) for chest radiography, non-contrast head computed tomography and mammography examinations in Nigeria: review of national data
    Kenneth Chukwudi Eze
    Felix Uduma
    Olubukola Abeni Omidiji
    Nkemakolam Kenneth Ibekwe
    Ahmed Ahidjo
    Philip Oluleke Ibinaiye
    Ismail Anas
    Ukamaka Dorothy Itanyi
    Blessing Ose-Emenim Igbinedion
    Godwin Inalegwu Ogbole
    Gbolahan Olusegun Awosanya
    [J]. Chinese Journal of Academic Radiology, 2022, 5 : 99 - 106
  • [9] Diagnostic reference levels (DRLs) for chest radiography, non-contrast head computed tomography and mammography examinations in Nigeria: review of national data
    Eze, Kenneth Chukwudi
    Uduma, Felix
    Omidiji, Olubukola Abeni
    Ibekwe, Nkemakolam Kenneth
    Ahidjo, Ahmed
    Ibinaiye, Philip Oluleke
    Anas, Ismail
    Itanyi, Ukamaka Dorothy
    Igbinedion, Blessing Ose-Emenim
    Ogbole, Godwin Inalegwu
    Awosanya, Gbolahan Olusegun
    [J]. CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2022, 5 (02) : 99 - 106
  • [10] Mammography Diagnostic Reference Levels (DRLs) in Ghana
    Dzidzornu, E.
    Angmorterh, S. K.
    Ofori-Manteaw, B. B.
    Aboagye, S.
    Dzefi-Tettey, K.
    Ofori, E. K.
    [J]. RADIOGRAPHY, 2021, 27 (02) : 611 - 616