Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates

被引:4
|
作者
Alrehily, Faisal A. [1 ]
Alqahtani, Khalid S. [1 ]
Aljohani, Marwan H. [1 ]
Alharbi, Nawaf S. [1 ]
Alharbi, Reyan M. [2 ]
Abdulaal, Osamah M. [1 ]
Alshamrani, Abdullah F. [1 ]
Alsaedi, Abdulrahman S. [3 ]
Al-Murshedi, Sadeq H. [4 ,5 ]
Alhazmi, Fahad H. [1 ]
机构
[1] Taibah Univ, Dept Diag Radiol Technol, Coll Appl Med Sci, Al Madinah Al Munawwarah, Saudi Arabia
[2] King Salman bin Abdulaziz Med City, Dept Radiol, Riyadh, Saudi Arabia
[3] King Fahad Gen Hosp, Dept Nucl Med, Al Madinah Al Munawwarah, Saudi Arabia
[4] AL Zahraa Univ Women, Coll Hlth & Med Technol, Dept Radiol Tech, Karbala, Iraq
[5] Univ Babylon, Coll Educ Pure Sci, Phys Dept, Babylon, Iraq
关键词
CT; DRL; CTDIvol; DLP; SSDE; effective diameter; CT; RADIATION; WEIGHT; CANCER; CHEST;
D O I
10.15537/smj.2023.44.8.20230230
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To establish local DRL (LDRL) for computed tomography (CT) examinations based on size-specific dose estimates (SSDEs), which consider patient size. The concept of diagnostic reference level (DRL) was introduced to limit patient exposure to unnecessary radiation. However, traditional DRL values do not consider patient size. Methods: Following institutional committee approval, data were collected from CT examinations of adult patients at Madinah General Hospital, Al Madinah Al Munawwarah, Saudi Arabia from January to March 2023. The SSDE was calculated for each patient using the effective diameter (D-eff). Results: The LDRLs of the brain, cervical spine, chest, thoracic spine and kidneys, ureters, and bladder (KUB) examinations were 118 mGy, 12 mGy, 8 mGy, 17 mGy, and 7 mGy, respectively. A strong correlation was observed between SSDEs and the volume computed tomography dose index (CTDIvol) for all examinations except chest scans (p<0.05). Size-specific dose estimates were higher than the CTDIvol, with a greater difference for patients with smaller Deff (p<0.05). Conclusion: The established LDRL was within the international DRL. The use of SSDE has the potential to provide more accurate and relevant data for radiation safety practices; however, widespread adoption of SSDE in new CT scanners is necessary for promoting consistency and standardization methodologies.
引用
收藏
页码:761 / 766
页数:6
相关论文
共 50 条
  • [21] Advancing size-specific dose estimates in CT examinations: Dose estimates at longitudinal positions of scans
    Li, Xinhua
    Marschall, Theodore A.
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2022, 49 (02) : 1303 - 1311
  • [22] Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Hanaoka, Shinsuke
    Matsubara, Kosuke
    Takata, Tadanori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 246 - 251
  • [23] SIMPLE METHOD OF SIZE-SPECIFIC DOSE ESTIMATES CALCULATION FROM PATIENT WEIGHT ON COMPUTED TOMOGRAPHY
    Iriuchijima, Akiko
    Fukushima, Yasuhiro
    Nakajima, Takahito
    Tsushima, Yoshito
    Ogura, Akio
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (02) : 208 - 212
  • [24] Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations
    Hamza Sulemana
    Abdul Nashirudeen Mumuni
    Izre-deen Osman Mohammed Abubakari
    Egyptian Journal of Radiology and Nuclear Medicine, 55 (1):
  • [25] Novel method for calculating the effective dose using size-specific dose estimates conversion factors in abdomen–pelvis computed tomography
    Kentaro Funashima
    Shigeru Abiko
    Kazuhiro Sato
    Radiological Physics and Technology, 2023, 16 (4) : 506 - 515
  • [26] ESTABLISHING LOCAL DIAGNOSTIC REFERENCE LEVELS FOR ROUTINE COMPUTED TOMOGRAPHY EXAMINATIONS IN JIMMA UNIVERSITY MEDICAL CENTER SOUTH WEST ETHIOPIA
    Zewdu, Mesfin
    Kadir, Elias
    Tesfaye, Million
    Berhane, Melkamu
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (3-4) : 200 - 206
  • [27] RADIATION DOSE DETERMINATION IN ABDOMINAL CT EXAMINATIONS OF CHILDREN AT SUDANESE HOSPITALS USING SIZE-SPECIFIC DOSE ESTIMATES
    Bashier, Einas H.
    Suliman, I. I.
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) : 444 - 449
  • [28] Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
    Radaideh, Khaldoon
    Al-Radaideh, Ali
    Ramli, Ramzun Maizan
    Saleh, Abdallah
    Alshayeb, Rasha
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 26 - 34
  • [29] Novel method for calculating the effective dose using size-specific dose estimates conversion factors in abdomen-pelvis computed tomography
    Funashima, Kentaro
    Abiko, Shigeru
    Sato, Kazuhiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (04) : 506 - 515
  • [30] DERIVATION OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON ADULT COMPUTED TOMOGRAPHY EXAMINATIONS IN MOROCCAN HOSPITAL
    Benmessaoud, M.
    Housni, A.
    Elmabrouki, M.
    Essasnaoui, F.
    Sadiki, N.
    Dadouch, A.
    Labzour, A.
    RADIATION PROTECTION DOSIMETRY, 2021, 194 (04) : 208 - 213