Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver Comparison to Conventional Free-Breathing Turbo Spin Echo

被引:10
|
作者
Ichinohe, Fumihito [1 ]
Oyama, Kazuki [1 ]
Yamada, Akira [1 ]
Hayashihara, Hayato [2 ]
Adachi, Yasuo [2 ]
Kitoh, Yoshihiro [2 ]
Kanki, Yusuke [3 ]
Maruyama, Katsuya [4 ]
Nickel, Marcel Dominik [5 ]
Fujinaga, Yasunari [1 ]
机构
[1] Shinshu Univ, Sch Med, Dept Radiol, 3-1-1 Asahi, Matsumoto 3908621, Japan
[2] Shinshu Univ Hosp, Radiol Div, Matsumoto, Japan
[3] Siemens Healthcare KK, Magnet Resonance Dept, Tokyo, Japan
[4] Siemens Healthcare KK, MR Res & Collaborat Dept, Tokyo, Japan
[5] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
关键词
magnetic resonance imaging; T2-weighted image; liver; deep learning; free-breathing; breath-hold; turbo spin echo; half Fourier single-shot turbo spin echo; BLADE TECHNIQUE; MRI; QUALITY; ABDOMEN; FEASIBILITY; ACQUISITION; SEQUENCE; HASTE; T2WI;
D O I
10.1097/RLI.0000000000000943
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the usefulness of breath-hold turbo spin echo with deep learning-based reconstruction (BH-DL-TSE) in acquiring fat-suppressed T2-weighted images (FS-T2WI) of the liver by comparing this method with conventional free-breathing turbo spin echo (FB-TSE) and breath-hold half Fourier single-shot turbo spin echo with deep learning-based reconstruction (BH-DL-HASTE).Materials and MethodsThe study cohort comprised 111 patients with suspected liver disease who underwent 3 T magnetic resonance imaging. Fifty-eight focal solid liver lesions >= 10 mm were also evaluated. Three sets of FS-T2WI were acquired using FB-TSE, prototypical BH-DL-TSE, and prototypical BH-DL-HASTE, respectively. In the qualitative analysis, 2 radiologists evaluated the image quality using a 5-point scale. In the quantitative analysis, we calculated the lesion-to-liver signal intensity ratio (LEL-SIR). Friedman test and Dunn multiple comparison test were performed to assess differences among 3 types of FS-T2WI with respect to image quality and LEL-SIR.ResultsThe mean acquisition time was 4 minutes and 43 seconds +/- 1 minute and 21 seconds (95% confidence interval, 4 minutes and 28 seconds to 4 minutes and 58 seconds) for FB-TSE, 40 seconds for BH-DL-TSE, and 20 seconds for BH-DL-HASTE. In the qualitative analysis, BH-DL-HASTE resulted in the fewest respiratory motion artifacts (P < 0.0001). BH-DL-TSE and FB-TSE exhibited significantly less motion-related signal loss and clearer intrahepatic vessels than BH-DL-HASTE (P < 0.0001). Regarding the edge sharpness of the left lobe, BH-DL-HASTE scored the highest (P < 0.0001), and BH-DL-TSE scored higher than FB-TSE (P = 0.0290). There were no significant differences among 3 types of FS-T2WI with respect to the edge sharpness of the right lobe (P = 0.1290), lesion conspicuity (P = 0.5292), and LEL-SIR (P = 0.6026).ConclusionsBH-DL-TSE provides a shorter acquisition time and comparable or better image quality than FB-TSE, and could replace FB-TSE in acquiring FS-T2WI of the liver. BH-DL-TSE and BH-DL-HASTE have their own advantages and may be used complementarily.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [41] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [42] Comparison Between Isotropic 3-Dimensional Fat-Suppressed T2-Weighted Fast Spin Echo (FSE) and Conventional 2-Dimensional Fat-Suppressed Proton-Weighted FSE Shoulder Magnetic Resonance Imaging at 3-T in Patients With Shoulder Pain
    Horiuchi, Saya
    Nozaki, Taiki
    Tasaki, Atsushi
    Ohde, Sachiko
    Deshpande, Gautam A.
    Starkey, Jay
    Hara, Takeshi
    Kitamura, Nobuto
    Yoshioka, Hiroshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (04) : 559 - 565
  • [43] Comparison of dual spin echo echo planar imaging (SE_EPI), turbo spin echo with fat suppression and conventional dual spin echo sequences for T2-weighted MR imaging of focal liver lesions
    Papanikolaou, N
    Moulopoulos, LA
    Gouliamos, A
    Ispanopoulou, S
    Vlahos, L
    MAGNETIC RESONANCE IMAGING, 2000, 18 (06) : 715 - 719
  • [44] Comparison of fat-suppressed T2-weighted fast spin-echo sequence and modified STIR sequence in the evaluation of the rotator cuff tendon.
    Kijowski, R
    Farber, JM
    Medina, J
    Morrison, W
    Ying, J
    Buckwalter, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (02) : 371 - 378
  • [45] Fat-suppressed fast spin-echo mid-TE (TE[effective]=34) MR images: comparison with fast spin-echo T2-weighted images for the diagnosis of tears and anatomic variants of the glenoid labrum
    Tuite, MJ
    Shinners, TJ
    Hollister, MC
    Orwin, JF
    SKELETAL RADIOLOGY, 1999, 28 (12) : 685 - 690
  • [46] Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction
    Asbach, P
    Klessen, C
    Kroencke, TJ
    Kluner, C
    Stemmer, A
    Hamm, B
    Taupitz, M
    MAGNETIC RESONANCE IMAGING, 2005, 23 (09) : 939 - 945
  • [47] Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction
    Klessen, C
    Asbach, P
    Kroencke, TJ
    Fischer, T
    Warmuth, C
    Stemmer, A
    Hamm, B
    Taupitz, M
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 576 - 582
  • [48] Fat-suppressed fast spin-echo mid-TE (TE[effective]=34) MR images: comparison with fast spin-echo T2-weighted images for the diagnosis of tears and anatomic variants of the glenoid labrum
    Michael J. Tuite
    Theodore J. Shinners
    Mark C. Hollister
    John F. Orwin
    Skeletal Radiology, 1999, 28 : 685 - 690
  • [49] Single-breath-hold T2WI liver MRI with deep learning-based reconstruction: A clinical feasibility study in comparison to conventional multi-breath-hold T2WI liver MRI
    Sheng, Ruo-fan
    Zheng, Li-yun
    Jin, Kai-pu
    Sun, Wei
    Liao, Shu
    Zeng, Meng-su
    Dai, Yong-ming
    MAGNETIC RESONANCE IMAGING, 2021, 81 : 75 - 81
  • [50] Comparison of model-based versus deep learning-based image reconstruction for thin-slice T2-weighted spin-echo prostate MRI
    Riederer, Stephen J.
    Borisch, Eric A.
    Froemming, Adam T.
    Kawashima, Akira
    Takahashi, Naoki
    ABDOMINAL RADIOLOGY, 2024, 49 (08) : 2921 - 2931