Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver Comparison to Conventional Free-Breathing Turbo Spin Echo

被引:10
|
作者
Ichinohe, Fumihito [1 ]
Oyama, Kazuki [1 ]
Yamada, Akira [1 ]
Hayashihara, Hayato [2 ]
Adachi, Yasuo [2 ]
Kitoh, Yoshihiro [2 ]
Kanki, Yusuke [3 ]
Maruyama, Katsuya [4 ]
Nickel, Marcel Dominik [5 ]
Fujinaga, Yasunari [1 ]
机构
[1] Shinshu Univ, Sch Med, Dept Radiol, 3-1-1 Asahi, Matsumoto 3908621, Japan
[2] Shinshu Univ Hosp, Radiol Div, Matsumoto, Japan
[3] Siemens Healthcare KK, Magnet Resonance Dept, Tokyo, Japan
[4] Siemens Healthcare KK, MR Res & Collaborat Dept, Tokyo, Japan
[5] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
关键词
magnetic resonance imaging; T2-weighted image; liver; deep learning; free-breathing; breath-hold; turbo spin echo; half Fourier single-shot turbo spin echo; BLADE TECHNIQUE; MRI; QUALITY; ABDOMEN; FEASIBILITY; ACQUISITION; SEQUENCE; HASTE; T2WI;
D O I
10.1097/RLI.0000000000000943
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the usefulness of breath-hold turbo spin echo with deep learning-based reconstruction (BH-DL-TSE) in acquiring fat-suppressed T2-weighted images (FS-T2WI) of the liver by comparing this method with conventional free-breathing turbo spin echo (FB-TSE) and breath-hold half Fourier single-shot turbo spin echo with deep learning-based reconstruction (BH-DL-HASTE).Materials and MethodsThe study cohort comprised 111 patients with suspected liver disease who underwent 3 T magnetic resonance imaging. Fifty-eight focal solid liver lesions >= 10 mm were also evaluated. Three sets of FS-T2WI were acquired using FB-TSE, prototypical BH-DL-TSE, and prototypical BH-DL-HASTE, respectively. In the qualitative analysis, 2 radiologists evaluated the image quality using a 5-point scale. In the quantitative analysis, we calculated the lesion-to-liver signal intensity ratio (LEL-SIR). Friedman test and Dunn multiple comparison test were performed to assess differences among 3 types of FS-T2WI with respect to image quality and LEL-SIR.ResultsThe mean acquisition time was 4 minutes and 43 seconds +/- 1 minute and 21 seconds (95% confidence interval, 4 minutes and 28 seconds to 4 minutes and 58 seconds) for FB-TSE, 40 seconds for BH-DL-TSE, and 20 seconds for BH-DL-HASTE. In the qualitative analysis, BH-DL-HASTE resulted in the fewest respiratory motion artifacts (P < 0.0001). BH-DL-TSE and FB-TSE exhibited significantly less motion-related signal loss and clearer intrahepatic vessels than BH-DL-HASTE (P < 0.0001). Regarding the edge sharpness of the left lobe, BH-DL-HASTE scored the highest (P < 0.0001), and BH-DL-TSE scored higher than FB-TSE (P = 0.0290). There were no significant differences among 3 types of FS-T2WI with respect to the edge sharpness of the right lobe (P = 0.1290), lesion conspicuity (P = 0.5292), and LEL-SIR (P = 0.6026).ConclusionsBH-DL-TSE provides a shorter acquisition time and comparable or better image quality than FB-TSE, and could replace FB-TSE in acquiring FS-T2WI of the liver. BH-DL-TSE and BH-DL-HASTE have their own advantages and may be used complementarily.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [31] UNSUPPRESSED FAT IN THE RIGHT ANTERIOR DIAPHRAGMATIC REGION ON FAT-SUPPRESSED T2-WEIGHTED FAST SPIN-ECHO MR-IMAGES
    YOSHIMITSU, K
    VARMA, DGK
    JACKSON, EF
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02): : 145 - 149
  • [32] Feasibility of application of sensitivity encoding to the breath-hold T2-weighted turbo spin-echo sequence for evaluation of focal hepatic tumors
    Kim, YK
    Kim, CS
    Chung, GH
    Bin Jeon, S
    Lee, JM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 497 - 504
  • [33] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182
  • [34] Usefulness of T2-Weighted Images with Deep-Learning-Based Reconstruction in Nasal Cartilage
    Gao, Yufan
    Liu, Weiyin
    Li, Liang
    Liu, Changsheng
    Zha, Yunfei
    DIAGNOSTICS, 2023, 13 (19)
  • [35] Assessment of coronary artery bypass graft patency with a 2D T2-weighted breath-hold Turbo-Spin-Echo sequence (HASTE)
    Kalden, P
    Kreitner, KF
    Wittlinger, T
    Voigtländer, T
    Krummenauer, F
    Schreiber, W
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 442 - 448
  • [36] T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences
    Masui, T
    Katayama, M
    Kobayashi, S
    Sakahara, H
    Ito, T
    Nozaki, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 930 - 937
  • [37] T2-WEIGHTED MR IMAGING OF FOCAL HEPATIC-LESIONS - COMPARISON OF VARIOUS RARE AND FAT-SUPPRESSED SPIN-ECHO SEQUENCES
    SEMELKA, RC
    SHOENUT, JP
    KROEKER, RM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02): : 323 - 327
  • [38] Image quality and focal lesion detection on T2-weighted MR imaging of the liver: Comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques
    Lee, Seung Soo
    Byun, Jae Ho
    Hong, Hye-Suk
    Park, Seong Ho
    Won, Hyung Jin
    Shin, Yong Moon
    Lee, Moon-Gyu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) : 323 - 330
  • [39] T2-weighted MR imaging of hepatic hemangiomas: Comparison of breath-hold and conventional turbo SE pulse sequences with the phased-array coil
    Choi, BI
    Wang, WC
    Kim, TK
    Han, JK
    Han, MC
    RADIOLOGY, 1996, 201 : 476 - 476
  • [40] Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences
    Augui, J
    Vignaux, O
    Argaud, C
    Coste, J
    Gouya, H
    Legmann, P
    RADIOLOGY, 2002, 223 (03) : 853 - 859