Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver Comparison to Conventional Free-Breathing Turbo Spin Echo

被引:10
|
作者
Ichinohe, Fumihito [1 ]
Oyama, Kazuki [1 ]
Yamada, Akira [1 ]
Hayashihara, Hayato [2 ]
Adachi, Yasuo [2 ]
Kitoh, Yoshihiro [2 ]
Kanki, Yusuke [3 ]
Maruyama, Katsuya [4 ]
Nickel, Marcel Dominik [5 ]
Fujinaga, Yasunari [1 ]
机构
[1] Shinshu Univ, Sch Med, Dept Radiol, 3-1-1 Asahi, Matsumoto 3908621, Japan
[2] Shinshu Univ Hosp, Radiol Div, Matsumoto, Japan
[3] Siemens Healthcare KK, Magnet Resonance Dept, Tokyo, Japan
[4] Siemens Healthcare KK, MR Res & Collaborat Dept, Tokyo, Japan
[5] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
关键词
magnetic resonance imaging; T2-weighted image; liver; deep learning; free-breathing; breath-hold; turbo spin echo; half Fourier single-shot turbo spin echo; BLADE TECHNIQUE; MRI; QUALITY; ABDOMEN; FEASIBILITY; ACQUISITION; SEQUENCE; HASTE; T2WI;
D O I
10.1097/RLI.0000000000000943
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the usefulness of breath-hold turbo spin echo with deep learning-based reconstruction (BH-DL-TSE) in acquiring fat-suppressed T2-weighted images (FS-T2WI) of the liver by comparing this method with conventional free-breathing turbo spin echo (FB-TSE) and breath-hold half Fourier single-shot turbo spin echo with deep learning-based reconstruction (BH-DL-HASTE).Materials and MethodsThe study cohort comprised 111 patients with suspected liver disease who underwent 3 T magnetic resonance imaging. Fifty-eight focal solid liver lesions >= 10 mm were also evaluated. Three sets of FS-T2WI were acquired using FB-TSE, prototypical BH-DL-TSE, and prototypical BH-DL-HASTE, respectively. In the qualitative analysis, 2 radiologists evaluated the image quality using a 5-point scale. In the quantitative analysis, we calculated the lesion-to-liver signal intensity ratio (LEL-SIR). Friedman test and Dunn multiple comparison test were performed to assess differences among 3 types of FS-T2WI with respect to image quality and LEL-SIR.ResultsThe mean acquisition time was 4 minutes and 43 seconds +/- 1 minute and 21 seconds (95% confidence interval, 4 minutes and 28 seconds to 4 minutes and 58 seconds) for FB-TSE, 40 seconds for BH-DL-TSE, and 20 seconds for BH-DL-HASTE. In the qualitative analysis, BH-DL-HASTE resulted in the fewest respiratory motion artifacts (P < 0.0001). BH-DL-TSE and FB-TSE exhibited significantly less motion-related signal loss and clearer intrahepatic vessels than BH-DL-HASTE (P < 0.0001). Regarding the edge sharpness of the left lobe, BH-DL-HASTE scored the highest (P < 0.0001), and BH-DL-TSE scored higher than FB-TSE (P = 0.0290). There were no significant differences among 3 types of FS-T2WI with respect to the edge sharpness of the right lobe (P = 0.1290), lesion conspicuity (P = 0.5292), and LEL-SIR (P = 0.6026).ConclusionsBH-DL-TSE provides a shorter acquisition time and comparable or better image quality than FB-TSE, and could replace FB-TSE in acquiring FS-T2WI of the liver. BH-DL-TSE and BH-DL-HASTE have their own advantages and may be used complementarily.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [21] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    Lee, MG
    Jeong, YK
    Kim, JC
    Kang, EM
    Kim, PN
    Auh, YH
    Chien, D
    Laub, G
    ABDOMINAL IMAGING, 2000, 25 (01): : 93 - 99
  • [22] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    M.-G. Lee
    Y. K. Jeong
    J. C. Kim
    E. M. Kang
    P. N. Kim
    Y. H. Auh
    D. Chien
    G. Laub
    Abdominal Imaging, 2000, 25 : 93 - 99
  • [23] Free-breathing BLADE fat-suppressed T2 weighted turbo spin echo sequence for distinguishing lung cancer from benign pulmonary nodules or masses: A pilot study
    Dang, Shan
    Ma, Guangming
    Duan, Haifeng
    Han, Dong
    Yang, Qi
    Yu, Nan
    Yu, Yong
    Duan, Xiaoyi
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 79 - 85
  • [25] Fast breath-hold T2-weighted MRI of the kidney by means of half-Fourier single-shot turbo spin echo: Comparison with high resolution turbo spin echo sequence
    Nakayama, Y
    Yamashita, Y
    Matsuno, Y
    Tang, Y
    Namimoto, T
    Kadota, M
    Mitsuzaki, K
    Abe, Y
    Katahira, K
    Arakawa, A
    Takahashi, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (01) : 55 - 60
  • [26] Detection and characterization of focal hepatic lesions by T2-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences
    Lee, Ho Yun
    Lee, Jeong Min
    Kim, Se Hyung
    Shin, Kyung Sook
    Lee, Jae Young
    Han, Joon Koo
    Choi, Byung Ihn
    CLINICAL IMAGING, 2009, 33 (04) : 281 - 288
  • [27] Fat-suppressed T2-weighted MR imaging of hepatocellular carcinoma and metastases: Comparison of conventional spin-echo, fast spin-echo, and echoplanar pulse sequences
    Kanematsu, M
    Hoshi, H
    Murakami, T
    Itoh, K
    Hori, M
    Inaba, Y
    Kondo, H
    Yokoyama, R
    Nakamura, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (01): : 25 - 32
  • [28] T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
    T. K. Kim
    W. C. Wang
    J. K. Han
    S. G. Cho
    B. I. Choi
    Abdominal Imaging, 1998, 23 : 422 - 426
  • [29] T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
    Kim, TK
    Wang, WC
    Han, JK
    Cho, SG
    Choi, BI
    ABDOMINAL IMAGING, 1998, 23 (04): : 422 - 426
  • [30] Comparison of breath-hold multishot echo-planar and respiratory triggered fast-spin-echo sequences for T2-weighted MRI of liver lesions
    Yamakado, K
    Sakuma, H
    Murashima, S
    Nakatsuka, A
    Matsumura, K
    Takeda, K
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 432 - 437