Intravascular imaging modalities in coronary intervention: Insights from 3D-printed phantom coronary models

被引:1
|
作者
Oliveira, Catarina [1 ]
Brito, Joana [1 ]
Rodrigues, Tiago [1 ]
Santiago, Helena [1 ]
Ricardo, Daniela [1 ]
Cardoso, Pedro [1 ,2 ]
Pinto, Fausto J. [1 ,2 ]
Marques, Joao Silva [1 ,2 ]
机构
[1] CHULN Hosp Santa Maria, Dept Coracao & Vasos, Serv Cardiol, Lisbon, Portugal
[2] Univ Lisbon, Ctr Cardiovasc Univ Lisboa CCUL RISE, Fac Med, Struct & Coronary Heart Dis Unit, Lisbon, Portugal
关键词
IVUS; OCT; Percutaneous coronary intervention; 3D-printing; OPTICAL-COHERENCE-TOMOGRAPHY; STENT IMPLANTATION; ULTRASOUND; IVUS;
D O I
10.1016/j.repc.2023.03.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: Several studies comparing optical coherence tomography (OCT) and intravascular ultrasound (IVUS) have revealed that OCT consistently provides smaller area and diameter measurements. However, comparative assessment in clinical practice is difficult. Three-dimensional (3D) printing offers a unique opportunity to assess intravascular imaging modalities.We aim to compare intravascular imaging modalities using a 3D-printed coronary artery in a realistic simulator and to assess whether OCT underestimates intravascular dimensions, exploring potential corrections.Methods: A standard realistic left main anatomy with an ostial left anterior descending artery lesion was replicated using 3D printing. After provisional stenting and optimization, IVI was obtained. Modalities included 20 MHz digital IVUS, 60 MHz rotational IVUS (HD-IVUS) and OCT. We assessed luminal area and diameters at standard locations.Results: Considering all coregistered measurements, OCT significantly underestimated area, minimal diameter and maximal diameter measurements in comparison to IVUS and HD-IVUS (p<0.001). No significant differences were found between IVUS and HD-IVUS.A significant systematic dimensional error was found in OCT auto-calibration by comparing known reference diameter of guiding catheter (1.8 mm) to measured mean diameter (1.68 mm & PLUSMN;0.04 mm). By applying a correction factor based on the reference guiding catheter area to OCT, the luminal areas and diameters were not significantly different compared to IVUS and HD-IVUS.Conclusion: Our findings suggest that automatic spectral calibration method for OCT is inaccurate, with a systematic underestimation of luminal dimensions. When guiding catheter correction is applied the performance of OCT is significantly improved. These results may be clinically relevant and need to be validated.& COPY; 2023 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espan & SIM;a, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/).
引用
收藏
页码:629 / 639
页数:11
相关论文
共 50 条
  • [1] Quantification of the uncertainty in coronary CTA plaque measurements using dynamic cardiac phantom and 3D-printed plaque models
    Richards, Taylor
    Sturgeon, Gregory M.
    Ramirez-Giraldo, Juan Carlos
    Rubin, Geoffrey
    Segars, Paul
    Samei, Ehsan
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [2] 3D-Printed Coronary Implants Are Effective for Percutaneous Creation of Swine Models with Focal Coronary Stenosis
    Caroline M. Colbert
    Jiaxin Shao
    John J. Hollowed
    Jesse W. Currier
    Olujimi A. Ajijola
    Gregory A. Fishbein
    Sandra M. Duarte-Vogel
    Rohan Dharmakumar
    Peng Hu
    Kim-Lien Nguyen
    Journal of Cardiovascular Translational Research, 2020, 13 : 1033 - 1043
  • [3] 3D-Printed Coronary Implants Are Effective for Percutaneous Creation of Swine Models with Focal Coronary Stenosis
    Colbert, Caroline M.
    Shao, Jiaxin
    Hollowed, John J.
    Currier, Jesse W.
    Ajijola, Olujimi A.
    Fishbein, Gregory A.
    Duarte-Vogel, Sandra M.
    Dharmakumar, Rohan
    Hu, Peng
    Nguyen, Kim-Lien
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2020, 13 (06) : 1033 - 1043
  • [4] Characterization of coronary atherosclerosis by intravascular imaging modalities
    Honda, Satoshi
    Kataoka, Yu
    Kanaya, Tomoaki
    Noguchi, Teruo
    Ogawa, Hisao
    Yasuda, Satoshi
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2016, 6 (04) : 368 - 381
  • [5] Prediction of postpercutaneous coronary intervention myocardial infarction: insights from intravascular imaging, coronary flow, and biomarker evaluation
    Hoole, Stephen P.
    Hernandez-Sanchez, Jules
    Brown, Adam J.
    Giblett, Joel P.
    Bennett, Martin R.
    West, Nick E. J.
    CORONARY ARTERY DISEASE, 2018, 29 (03) : 246 - 253
  • [6] Intravascular imaging in percutaneous coronary intervention
    Lee, Zhong Shiun
    Ryan, Nicola
    LANCET, 2024, 403 (10429): : 783 - 785
  • [7] Intravascular Imaging for Complex Coronary Intervention
    Guner, Ahmet
    Akturk, Ibrahim Faruk
    Cizgici, Ahmet Yasar
    Uzun, Fatih
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (21) : e207 - e207
  • [8] Evaluation of an integrated 3D-printed phantom for coronary CT angiography using iterative reconstruction algorithm
    Abdullah, Kamarul A.
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (03) : 170 - 176
  • [9] Coronary artery aneurysm following stent implantation: insights from serial multiple intravascular imaging modalities
    Mattesini, Alessio
    Valente, Serafina
    Foin, Nicolas
    Di Mario, Carlo
    Meucci, Francesco
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (04) : 467 - 467
  • [10] Personalized 3D printed coronary models in coronary stenting
    Sun, Zhonghua
    Jansen, Shirley
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (08) : 1356 - 1367