Intravascular imaging modalities in coronary intervention: Insights from 3D-printed phantom coronary models

被引:1
|
作者
Oliveira, Catarina [1 ]
Brito, Joana [1 ]
Rodrigues, Tiago [1 ]
Santiago, Helena [1 ]
Ricardo, Daniela [1 ]
Cardoso, Pedro [1 ,2 ]
Pinto, Fausto J. [1 ,2 ]
Marques, Joao Silva [1 ,2 ]
机构
[1] CHULN Hosp Santa Maria, Dept Coracao & Vasos, Serv Cardiol, Lisbon, Portugal
[2] Univ Lisbon, Ctr Cardiovasc Univ Lisboa CCUL RISE, Fac Med, Struct & Coronary Heart Dis Unit, Lisbon, Portugal
关键词
IVUS; OCT; Percutaneous coronary intervention; 3D-printing; OPTICAL-COHERENCE-TOMOGRAPHY; STENT IMPLANTATION; ULTRASOUND; IVUS;
D O I
10.1016/j.repc.2023.03.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: Several studies comparing optical coherence tomography (OCT) and intravascular ultrasound (IVUS) have revealed that OCT consistently provides smaller area and diameter measurements. However, comparative assessment in clinical practice is difficult. Three-dimensional (3D) printing offers a unique opportunity to assess intravascular imaging modalities.We aim to compare intravascular imaging modalities using a 3D-printed coronary artery in a realistic simulator and to assess whether OCT underestimates intravascular dimensions, exploring potential corrections.Methods: A standard realistic left main anatomy with an ostial left anterior descending artery lesion was replicated using 3D printing. After provisional stenting and optimization, IVI was obtained. Modalities included 20 MHz digital IVUS, 60 MHz rotational IVUS (HD-IVUS) and OCT. We assessed luminal area and diameters at standard locations.Results: Considering all coregistered measurements, OCT significantly underestimated area, minimal diameter and maximal diameter measurements in comparison to IVUS and HD-IVUS (p<0.001). No significant differences were found between IVUS and HD-IVUS.A significant systematic dimensional error was found in OCT auto-calibration by comparing known reference diameter of guiding catheter (1.8 mm) to measured mean diameter (1.68 mm & PLUSMN;0.04 mm). By applying a correction factor based on the reference guiding catheter area to OCT, the luminal areas and diameters were not significantly different compared to IVUS and HD-IVUS.Conclusion: Our findings suggest that automatic spectral calibration method for OCT is inaccurate, with a systematic underestimation of luminal dimensions. When guiding catheter correction is applied the performance of OCT is significantly improved. These results may be clinically relevant and need to be validated.& COPY; 2023 Sociedade Portuguesa de Cardiologia. Published by Elsevier Espan & SIM;a, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/).
引用
收藏
页码:629 / 639
页数:11
相关论文
共 50 条
  • [31] Intensive lipid lowering agents and coronary atherosclerosis: Insights from intravascular imaging
    Di Giovanni, Giuseppe
    Nicholls, Stephen J.
    AMERICAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2022, 11
  • [32] Development of 3D-Printed Heterogeneous Tumour Phantom for Quantitative Analysis in PET/CT Imaging
    Tang, Ming Zhao
    Choo, Hui Leng
    Yeong, Chai Hong
    Wong, Yin How
    14TH INTERNATIONAL ENGINEERING AND COMPUTING RESEARCH CONFERENCE SHAPING THE FUTURE THROUGH MULTIDISCIPLINARY RESEARCH (EURECA 2020), 2021, 335
  • [33] 3D-printed breast phantom for multi-purpose and multi-modality imaging
    He, Yaoyao
    Liu, Yulin
    Dyer, Brandon A.
    Boone, John M.
    Liu, Shanshan
    Chen, Tiao
    Zheng, Fenglian
    Zhu, Ye
    Sun, Yong
    Rong, Yi
    Qiu, Jianfeng
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (01) : 63 - 74
  • [34] Diffusion-weighted imaging evaluation using a 3D-printed phantom for Stereotactic Radiosurgery
    Torfeh, T.
    Hammoud, R.
    Arunachalam, Y.
    Aouadi, S.
    Al-Hammadi, N.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S692 - S692
  • [35] Insights from CTA with Comparison to Modalities of Intravascular Ultrasound Imaging
    Burke B.
    Budoff M.J.
    Current Cardiovascular Imaging Reports, 2011, 4 (4) : 309 - 316
  • [36] Use of Intravascular Imaging During Chronic Total Occlusion Percutaneous Coronary Intervention: Insights from a Contemporary Multicenter Registry
    Karacsonyi, Judit
    Alaswad, Khaldoon
    Jaffer, Farouc
    Yeh, Robert
    Patel, Mitul
    Bahadorani, John
    Danek, Barbara Anna
    Karatasakis, Aris
    Doing, Anthony
    Grantham, J. Aaron
    Karmpaliotis, Dimitri
    Moses, Jeffrey
    Kirtane, Ajay
    Parikh, Manish
    Ali, Ziad
    Lombardi, William
    Kandzari, David
    Lembo, Nicholas
    Garcia, Santiago
    Wyman, R. Michael
    Alame, Aya
    Martinez-Parachini, Jose Roberto
    Phuong-Khanh Nguyen-Trong
    Resendes, Erica
    Kalsaria, Pratik
    Rangan, Bavana
    Ungi, Imre
    Thompson, Craig
    Banerjee, Subhash
    Brilakis, Emmanouil
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B231 - B231
  • [37] Use of Intravascular Imaging During Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From a Contemporary Multicenter Registry
    Karacsonyi, Judit
    Alaswad, Khaldoon
    Jaffer, Farouc A.
    Yeh, Robert W.
    Patel, Mitul
    Bahadorani, John
    Karatasakis, Aris
    Danek, Barbara A.
    Doing, Anthony
    Grantham, J. Aaron
    Karmpaliotis, Dimitri
    Moses, Jeffrey W.
    Kirtane, Ajay
    Parikh, Manish
    Ali, Ziad
    Lombardi, William L.
    Kandzari, David E.
    Lembo, Nicholas
    Garcia, Santiago
    Wyman, Michael R.
    Alame, Aya
    Nguyen-Trong, Phuong-Khanh J.
    Resendes, Erica
    Kalsaria, Pratik
    Rangan, Bavana V.
    Ungi, Imre
    Thompson, Craig A.
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (08):
  • [39] Comparison of Intravascular Imaging, Functional, or Angiographically Guided Coronary Intervention
    Kuno, Toshiki
    Kiyohara, Yuko
    Maehara, Akiko
    Ueyama, Hiroki A.
    Kampaktsis, Polydoros N.
    Takagi, Hisato
    Mehran, Roxana
    Stone, Gregg W.
    Bhatt, Deepak L.
    Mintz, Gary S.
    Bangalore, Sripal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (23) : 2167 - 2176
  • [40] Intravascular Imaging to Guide Percutaneous Coronary Intervention Will Be Mandatory Soon
    Maehara, Akiko
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (06)