Personalized 3D printed coronary models in coronary stenting

被引:28
|
作者
Sun, Zhonghua [1 ]
Jansen, Shirley [2 ,3 ,4 ,5 ]
机构
[1] Curtin Univ, Sch Mol & Life Sci, Discipline Med Radiat Sci, GPO Box U1987, Perth, WA 6845, Australia
[2] Sir Charles Gairdner Hosp, Dept Vasc & Endovasc Surg, Perth, WA 6009, Australia
[3] Curtin Univ, Curtin Med Sch, Perth, WA 6845, Australia
[4] Univ Western Australia, Fac Hlth & Med Sci, Crawley, WA 6009, Australia
[5] Harry Perkins Inst Med Res, Heart & Vasc Res Inst, Perth, WA 6009, Australia
关键词
Coronary stent; diameter; kernel; lumen; model; three-dimensional (3D) printing; visibility; visualization; VIRTUAL INTRAVASCULAR ENDOSCOPY; CT ANGIOGRAPHY; CARDIOVASCULAR-DISEASE; COMPUTED-TOMOGRAPHY; TRANSFORMATION; RESTENOSIS; DIAGNOSIS;
D O I
10.21037/qims.2019.06.21
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: 3D printing has shown great promise in cardiovascular disease, with reports mainly focusing on pre-surgical planning and medical education. Research on utilization of 3D printed models in simulating coronary stenting has not been reported. In this study, we presented our experience of placing coronary stents into personalized 3D printed coronary models with the aim of determining stent lumen visibility with images reconstructed with different postprocessing views and algorithms. Methods: A total of six coronary stents with diameter ranging from 2.5 to 4.0 mm were placed into 3 patient-specific 3D printed coronary models for simulation of coronary stenting. The 3D printed models were placed in a plastic container and scanned on a 192-slice third generation dual-source CT scanner with images reconstructed with soft (Bv36) and sharp (Bv59) kernel algorithms. Thick and thin slab maximum-intensity projection (MIP) images were also generated from the original CT data for comparison of stent lumen visibility. Stent lumen diameter was measured on 2D axial and MIP images, while stent diameter was measured on 3D volume rendering images. 3D virtual intravascular endoscopy (VIE) images were generated to provide intraluminal views of the coronary wall and stent appearances. Results: All of these stents were successfully placed into the right and left coronary arteries but 2 of them did not obtain wall apposition along the complete length. The stent lumen visibility ranged from 54 to 97%, depending on the stent location in the coronary arteries. The mean stent lumen diameters measured on 2D axial, thin and thick slab MIP images were found to be significantly smaller than the actual size (P<0.01). Thick slab MIP images resulted in measured stent lumen diameters smaller than those from thin slab MIP images, with significant differences noticed in most of the measurements (4 out of 6 stents) (P<0.05), and no significant differences in the remaining 2 stents (P=0.19-0.38). In contrast, 3D volume rendering images allowed for more accurate measurements with measured stent diameters close to the actual dimensions in most of these coronary stents, except for the stent placed at the right coronary artery in one of the models due to insufficient expansion of the stent. Images reconstructed with sharp kernel Bv59 significantly improved stent lumen visibility when compared to the smooth Bv36 kernel (P=0.01). 3D VIE was successfully generated in all of the datasets with clear visualization of intraluminal views of the stents in relation to the coronary wall. Conclusions: This preliminary report shows the feasibility of using 3D printed coronary artery models in coronary stenting for investigation of optimal coronary CT angiography protocols. Future studies should focus on placement of more stents with a range of stent diameters in the quest to reduce the need for invasive angiography for surveillance.
引用
收藏
页码:1356 / 1367
页数:12
相关论文
共 50 条
  • [1] 3D Printed Coronary Models Offer Potential Value in Visualising Coronary Anatomy and Coronary Stents for Investigation of Coronary CT Protocols
    Sun, Zhonghua
    CURRENT MEDICAL IMAGING, 2020, 16 (06) : 625 - 628
  • [2] Method to simulate distal flow resistance in coronary arteries in 3D printed patient specific coronary models
    Sommer, Kelsey N.
    Iyer, Vijay
    Kumamaru, Kanako Kunishima
    Rava, Ryan A.
    Ionita, Ciprian N.
    3D PRINTING IN MEDICINE, 2020, 6 (01)
  • [3] Method to simulate distal flow resistance in coronary arteries in 3D printed patient specific coronary models
    Kelsey N. Sommer
    Vijay Iyer
    Kanako Kunishima Kumamaru
    Ryan A. Rava
    Ciprian N. Ionita
    3D Printing in Medicine, 6
  • [4] 3D printed coronary models offer new opportunities for developing optimal coronary CT angiography protocols in imaging coronary stents
    Sun, Zhonghua
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (08) : 1350 - 1355
  • [5] 3D printed personalized, heparinized and biodegradable coronary artery stents for rabbit abdominal aorta implantation
    Shen, Yihong
    Tang, Chaojie
    Sun, Binbin
    Zhang, Yang
    Sun, Xiaolin
    EL-Newehy, Mohamed
    EL-Hamshary, Hany
    Morsi, Yosry
    Gu, Hongbing
    Wang, Wu
    Mo, Xiumei
    CHEMICAL ENGINEERING JOURNAL, 2022, 450
  • [6] Use of personalized 3D printed kidney models for partial nephrectomy
    Michiels, C.
    de Hauteclocque, A. Boulenger
    Sarrazin, J.
    Cornelis, F.
    Ricard, S.
    Faessel, M.
    Grenier, N.
    Bos, F.
    Bernhard, J. C.
    PROGRES EN UROLOGIE, 2020, 30 (15): : 970 - 975
  • [7] 3D printed models in patients with coronary artery fistulae: anatomical assessment and interventional planning
    Forte, Mari Nieves Velasco
    Byrne, Nick
    Perez, Israel Valverde
    Bell, Aaron
    Gomez-Ciriza, Gorka
    Krasemann, Thomas
    Sievert, Horst
    Simpson, John
    Pushparajah, Kuberan
    Razavi, Reza
    Qureshi, Shakeel
    Hussain, Tarique
    EUROINTERVENTION, 2017, 13 (09) : 1080 - 1083
  • [8] Desktop 3D printed anatomic models for minimally invasive direct coronary artery bypass
    Ravi, Prashanth
    Burch, Michael B.
    Giannopoulos, Andreas A.
    Liu, Isabella
    Kondor, Shayne
    Chepelev, Leonid L.
    Danesi, Tommaso H.
    Rybicki, Frank J.
    Panza, Antonio
    3D PRINTING IN MEDICINE, 2024, 10 (01)
  • [9] The Effect Of Stenting On Coronary Bifurcation Geometry- A 3D Analysis
    Behan, Miles W. H.
    Hassoon, Milad
    Haworth, Peter
    Hildick-Smith, David
    deBelder, Adam
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 83I - 84I
  • [10] 3D printed, personalized hydrocortisone for hypocortisolemia
    Ayyoubi, Sejad
    van den Akker, Erica
    Feelders, Richard
    Ruijgrok, Liesbeth
    HORMONE RESEARCH IN PAEDIATRICS, 2024, 97 : 47 - 47