The influence of gravity on electrical impedance tomography measurements during upper body position change

被引:5
|
作者
Yang, Lin [1 ]
Gao, Zhijun [1 ]
Cao, Xinsheng [1 ]
Fu, Feng [2 ]
Moller, Knut [3 ]
Frerichs, Inez [4 ]
Dai, Meng [2 ]
Zhao, Zhanqi [3 ]
机构
[1] Fourth Mil Med Univ, Dept Aerosp Med, Xian, Peoples R China
[2] Fourth Mil Med Univ, Dept Biomed Engn, Xian, Peoples R China
[3] Furtwangen Univ, Inst Tech Med, Villingen Schwenningen, Germany
[4] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
基金
中国国家自然科学基金; 欧盟地平线“2020”;
关键词
Electrical impedance tomography; Ventilation distribution; Upper body position; Diaphragm; Gravity; VENTILATION;
D O I
10.1016/j.heliyon.2023.e15910
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: The aim of the study was to examine the influence of gravity on regional ventilation measured by electrical impedance tomography (EIT) with the standard electrode belt position at the 5th intercostal space during tilting from supine to sitting positions. Methods: A total of 30 healthy volunteers were examined prospectively in supine position during quiet tidal breathing. Subsequently, the bed was tilted so that the upper body of the subjects achieved 30, 60 and 90 degrees every 3 min. Regional ventilation distribution and end-expiratory lung impedance (EELI) were monitored with EIT throughout the whole experiment. Absolute tidal volumes were measured with spirometry and the volume-impedance ratio was calculated for each position. Results: The volume-impedance ratio did not differ statistically between the studied body positions but 11 subjects exhibited a large change in ratio at one of the positions (outside 99.3% coverage). In general, ventilation distribution became more heterogeneous and moved towards dorsal regions as the upper body was tilted to 90-degree position. EELI increased and tidal volume decreased. The lung regions identified at various positions differed significantly. Conclusion: Gravity has non-negligible influence on EIT data, as the upper body tilted from supine to sitting positions. The standard electrode belt position might be reconsidered if ventilation distribution is to be compared between supine and sitting positions.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Accurate position estimation methods based on electrical impedance tomography measurements
    Vergara, Samuel
    Sbarbaro, Daniel
    Johansen, T. A.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (08)
  • [2] Influence of changing peripheral geometry on electrical impedance tomography measurements
    Gersing, E
    Hofmann, B
    Osypka, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (05) : 359 - 361
  • [3] Influence of changing peripheral geometry on electrical impedance tomography measurements
    Gersing, E.
    Hofmann, B.
    Osypka, M.
    Medical and Biological Engineering and Computing, 1996, 34 (05): : 359 - 361
  • [4] Oxygen Therapy Delivery and Body Position Effects Measured With Electrical Impedance Tomography
    Yuan, Zhiyong
    Han, Xiaoning
    Wang, Lisha
    Xue, Ping
    Sun, Yunbo
    Frerichs, Inez
    Moeller, Knut
    Xing, Jinyan
    Zhao, Zhanqi
    RESPIRATORY CARE, 2020, 65 (03) : 281 - 287
  • [5] The influence of body position on bioelectrical impedance spectroscopy measurements in young children
    Jaz Lyons-Reid
    Leigh C. Ward
    Mya-Thway Tint
    Timothy Kenealy
    Keith M. Godfrey
    Shiao-Yng Chan
    Wayne S. Cutfield
    Scientific Reports, 11
  • [6] The influence of body position on bioelectrical impedance spectroscopy measurements in young children
    Lyons-Reid, Jaz
    Ward, Leigh C.
    Tint, Mya-Thway
    Kenealy, Timothy
    Godfrey, Keith M.
    Chan, Shiao-Yng
    Cutfield, Wayne S.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [7] INFLUENCE OF BODY DIMENSIONS IN THE ANALYSIS OF PULMONARY PULSATILITY BY ELECTRICAL IMPEDANCE TOMOGRAPHY
    da Silva Ramos, F. J.
    Azevedo, L. C. P.
    Schettino, G. P. P.
    Amato, M. B. P.
    Costa, E. L. V.
    INTENSIVE CARE MEDICINE, 2012, 38 : S66 - S66
  • [8] Radio Frequency Measurements for Electrical Impedance Tomography
    Battistel, Alberto
    Wilkie, Jack
    Chen, Rongqing
    Karime, Ahmad
    Moeller, Knut
    IFAC PAPERSONLINE, 2024, 58 (24): : 608 - 613
  • [9] The influence of an electrical impedance tomography belt on lung function determined by spirometry in sitting position
    Zhang, Na
    Jiang, Hongying
    Zhang, Chenxi
    Li, Qing
    Li, Yi
    Zhang, Bin
    Deng, Jia
    Niu, Guangyu
    Yang, Bo
    Frerichs, Inez
    Moeller, Knut
    Fu, Feng
    Zhao, Zhanqi
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (04)
  • [10] Body electrical impedance measurements: Body fat or body fluid?
    Patterson, RP
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1746 - 1747