Effect of syringe underfilling on the quality of venous blood gas analysis

被引:2
|
作者
Lippi, Giuseppe [1 ]
Pighi, Laura [2 ,3 ]
Tosi, Marco [2 ,3 ]
Vettori, Marco [2 ,3 ]
Celegon, Giovanni [2 ,3 ]
Favaloro, Emmanuel J. [4 ,5 ,6 ]
Salvagno, Gian Luca [2 ,3 ]
机构
[1] Univ Hosp Verona, Sect Clin Biochem, Piazzale LA Scuro 10, I-37134 Verona, Italy
[2] Univ Verona, Sect Clin Biochem, Verona, Italy
[3] Univ Verona, Sch Med, Verona, Italy
[4] Westmead Hosp, Inst Clin Pathol & Med Res ICPMR, Sydney Ctr Thrombosis & Haemostasis, Dept Haematol, Westmead, NSW, Australia
[5] Univ Sydney, Westmead Hosp, Fac Med & Hlth, Sch Med Sci, Westmead, NSW, Australia
[6] Charles Sturt Univ, Fac Sci & Hlth, Wagga Wagga, NSW, Australia
关键词
blood gas analysis; syringe; underfilling; errors; preanalytical variability; HEPARIN; VOLUME;
D O I
10.1515/dx-2023-0096
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives There is limited information on the influence of collecting small amounts of blood on the quality of blood gas analysis. Therefore, the purpose of this study was to investigate the effects of different degrees of underfilling of syringes on test results of venous blood gas analysis.Methods Venous blood was collected by venipuncture from 19 healthcare workers in three 1.0 mL syringes for blood gas analysis, by manually aspirating different volumes of blood (i.e., 1.0, 0.5 and 0.25 mL). Routine blood gas analysis was then immediately performed with GEM Premier 5,000. The results of the two underfilled syringes were compared with those of the reference syringe filled with appropriate blood volume.Results The values of most assayed parameters did not differ significantly in the two underfilled syringes. Statistically significant variations were found for lactate, hematocrit and total hemoglobin, the values of which gradually increased as the fill volume diminished, as well as for sodium concentration, which decreased in both insufficiently filled blood gas syringes. The bias was clinically meaningful for lactate in syringe filled with 0.25 mL of blood, and for hematocrit, total hemoglobin and sodium in both syringes containing 0.5 and 0.25 mL of blood.Conclusions Collection of smaller volumes of venous blood than the specified filling volume in blood gas syringes may have an effect on the quality of some test results, namely lactate, hematocrit, total hemoglobin and sodium. Specific indications must be given for standardizing the volume of blood to be collected within these syringes.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 50 条
  • [41] EFFECT OF HEPARIN ON BLOOD-GAS ANALYSIS
    不详
    MEDICAL JOURNAL OF AUSTRALIA, 1979, 1 (06) : 221 - 221
  • [42] INHALATION OF OXYGEN AND CARBON DIOXIDE GAS - EFFECT ON COMPOSITION OF CEREBRAL VENOUS BLOOD
    MEYER, JS
    GOTOH, F
    TAKAGI, Y
    ARCHIVES OF INTERNAL MEDICINE, 1967, 119 (01) : 4 - &
  • [43] Gas analysis with an all glass syringe for pneumonia tents
    Henderson, Y
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1931, 96 : 1474 - 1475
  • [44] COMPARISON OF CONVENTIONAL BLOOD-GAS ANALYSIS AND AN ON-DEMAND BEDSIDE BLOOD-GAS MONITOR IN THE DETERMINATION OF MIXED VENOUS-BLOOD GAS VALUES
    PERUZZI, WT
    FRANKLIN, ML
    SHAPIRO, BA
    MOEN, SG
    ANESTHESIOLOGY, 1994, 81 (3A) : A620 - A620
  • [45] Costs of intermittent measurement of central venous oxygen saturations by blood gas analysis
    Frank Bloos
    Florian Rissner
    Martin Specht
    Konrad Reinhart
    Gernot Marx
    Intensive Care Medicine, 2009, 35 : 1316 - 1317
  • [46] Costs of intermittent measurement of central venous oxygen saturations by blood gas analysis
    Bloos, Frank
    Rissner, Florian
    Specht, Martin
    Reinhart, Konrad
    Marx, Gernot
    INTENSIVE CARE MEDICINE, 2009, 35 (07) : 1316 - 1317
  • [47] COMPARISON OF ARTERIAL AND MIXED VENOUS BLOOD GAS ANALYSIS IN CRITICALLY ILL PATIENTS
    Ji, Wonjun
    Kwon, Byoung Soo
    Moon, Do Sik
    Ahn, Jee Hwan
    Woo, Ala
    Oh, Dong Kyu
    Huh, Jin Won
    Hong, Sang-Bum
    Koh, Younsuck
    Lim, Chae-Man
    CRITICAL CARE MEDICINE, 2019, 47
  • [48] Heparin Concentration in Evacuated Tubes and Its Effect on pH, Ionized Calcium, Lactate, and Potassium in Venous Blood Gas Analysis
    Mahler, Katherine
    Kerlin, Rae
    Jones, Joanna
    Li, Jieli
    LABORATORY MEDICINE, 2023, 54 (05) : E157 - E160
  • [49] BLOOD-GAS ANALYSIS - INSTRUMENTATION AND QUALITY-CONTROL
    DEVGUN, MS
    FAIRWEATHER, GW
    MEDICAL LABORATORY SCIENCES, 1983, 40 (03): : 219 - 222
  • [50] STANDARDIZED QUALITY-CONTROL OF BLOOD-GAS ANALYSIS
    WITEK, F
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 1978, 128 (09) : 272 - 276