Effect of syringe underfilling on the quality of venous blood gas analysis

被引:2
|
作者
Lippi, Giuseppe [1 ]
Pighi, Laura [2 ,3 ]
Tosi, Marco [2 ,3 ]
Vettori, Marco [2 ,3 ]
Celegon, Giovanni [2 ,3 ]
Favaloro, Emmanuel J. [4 ,5 ,6 ]
Salvagno, Gian Luca [2 ,3 ]
机构
[1] Univ Hosp Verona, Sect Clin Biochem, Piazzale LA Scuro 10, I-37134 Verona, Italy
[2] Univ Verona, Sect Clin Biochem, Verona, Italy
[3] Univ Verona, Sch Med, Verona, Italy
[4] Westmead Hosp, Inst Clin Pathol & Med Res ICPMR, Sydney Ctr Thrombosis & Haemostasis, Dept Haematol, Westmead, NSW, Australia
[5] Univ Sydney, Westmead Hosp, Fac Med & Hlth, Sch Med Sci, Westmead, NSW, Australia
[6] Charles Sturt Univ, Fac Sci & Hlth, Wagga Wagga, NSW, Australia
关键词
blood gas analysis; syringe; underfilling; errors; preanalytical variability; HEPARIN; VOLUME;
D O I
10.1515/dx-2023-0096
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives There is limited information on the influence of collecting small amounts of blood on the quality of blood gas analysis. Therefore, the purpose of this study was to investigate the effects of different degrees of underfilling of syringes on test results of venous blood gas analysis.Methods Venous blood was collected by venipuncture from 19 healthcare workers in three 1.0 mL syringes for blood gas analysis, by manually aspirating different volumes of blood (i.e., 1.0, 0.5 and 0.25 mL). Routine blood gas analysis was then immediately performed with GEM Premier 5,000. The results of the two underfilled syringes were compared with those of the reference syringe filled with appropriate blood volume.Results The values of most assayed parameters did not differ significantly in the two underfilled syringes. Statistically significant variations were found for lactate, hematocrit and total hemoglobin, the values of which gradually increased as the fill volume diminished, as well as for sodium concentration, which decreased in both insufficiently filled blood gas syringes. The bias was clinically meaningful for lactate in syringe filled with 0.25 mL of blood, and for hematocrit, total hemoglobin and sodium in both syringes containing 0.5 and 0.25 mL of blood.Conclusions Collection of smaller volumes of venous blood than the specified filling volume in blood gas syringes may have an effect on the quality of some test results, namely lactate, hematocrit, total hemoglobin and sodium. Specific indications must be given for standardizing the volume of blood to be collected within these syringes.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 50 条
  • [21] PERIPHERAL VENOUS BLOOD GAS ANALYSIS VERSUS ARTERIAL BLOOD GAS ANALYSIS FOR THE DIAGNOSIS OF RESPIRATORY FAILURE AND METABOLIC DISTURBANCE IN ADULTS
    Byrne, A.
    Bennett, M.
    Pace, N.
    Thomas, P.
    Symons, R.
    Chatterji, R.
    RESPIROLOGY, 2018, 23 : 103 - 103
  • [22] EFFECT OF SAMPLING SITE ON FEMORAL VENOUS-BLOOD GAS VALUES
    AGUSTI, AGN
    ROCA, J
    BARBERA, JA
    CASADEMONT, J
    RODRIGUEZROISIN, R
    WAGNER, PD
    JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (04) : 2018 - 2022
  • [23] Effect of therapeutic doses of optical radiation on gas composition of venous blood
    G. A. Zalesskaya
    O. V. Laskina
    Journal of Applied Spectroscopy, 2013, 80 : 265 - 270
  • [24] Mixed venous and arterial blood in bovine coccygeal vessel samples for blood gas analysis
    Tvedten, H
    Kopcia, M
    Haines, C
    VETERINARY CLINICAL PATHOLOGY, 2000, 29 (01) : 4 - 6
  • [25] INFLUENCE OF SYRINGE MATERIAL ON ARTERIAL BLOOD-GAS DETERMINATIONS
    WINKLER, JB
    HUNTINGTON, CG
    WELLS, DE
    BEFELER, B
    CHEST, 1974, 66 (05) : 518 - 521
  • [26] Correlation of arterial and venous blood gas analysis in respiratory failure in children
    Sitti Aizah Lawang
    Idham Jayaganda
    Gracia Dewi Indrawati
    Destya Maulani
    Intensive Care Medicine – Paediatric and Neonatal, 2 (1):
  • [27] Mismatch of arterial and central venous blood gas analysis during haemorrhage
    Theusinger, Oliver M.
    Thyes, Caroline
    Frascarolo, Philippe
    Schramm, Sebastian
    Seifert, Burkhardt
    Spahn, Donat R.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (10) : 890 - 896
  • [28] Prognostic value of venous blood gas analysis in patients with diabetic ketoacidosis
    Zhao, Na
    Ma, Liang
    Bai, Sen
    Gao, Lifeng
    Zhao, Hui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (11): : 13005 - 13011
  • [29] Venous Blood Gas Analysis for HFJV for Catheter Ablation of Atrial Fibrillation
    O'Neill, Daniel K.
    Aizer, Anthony
    Linton, Patrick
    Chinitz, Larry
    ANESTHESIA AND ANALGESIA, 2017, 124 : 1090 - 1091
  • [30] Arterialisation of peripheral venous blood in pregnancy - a curious venous blood gas result
    As-Sultany, S.