Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System

被引:0
|
作者
Tajima, Shunsuke [1 ,2 ]
Isoda, Haruo [3 ,4 ]
Fukunaga, Masaki [5 ]
Komori, Yoshiaki [6 ]
Naganawa, Shinji [7 ]
Sadato, Norihiro [5 ,8 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol & Med Lab Sci, Radiol Sci, Nagoya, Aichi, Japan
[2] Nagoya Univ Hosp, Dept Radiol Technol, Nagoya, Aichi, Japan
[3] Nagoya Univ, Brain & Mind Res Ctr, Nagoya, Aichi, Japan
[4] Nagoya Univ, Grad Sch Med, Dept Integrated Hlth Sci, 1-1-20 Daiko Minami,Higashi Ku, Nagoya, Aichi 4618673, Japan
[5] Natl Inst Physiol Sci, Div Cerebral Integrat, Okazaki, Aichi, Japan
[6] Siemens Healthcare KK, Tokyo, Japan
[7] Nagoya Univ, Grad Sch Med, Dept Radiol, Nagoya, Aichi, Japan
[8] Ritsumeikan Univ, Res Org Sci & Technol, Kyoto, Kyoto, Japan
关键词
hemodynamics; intracranial artery; phase-contrast MR imaging; 4D flow MRI; magnetic field strength; UNRUPTURED INTRACRANIAL ANEURYSMS; SUBARACHNOID HEMORRHAGE; SHEAR-STRESS; FLOW; VELOCITY; RUPTURE; RISK; QUANTIFICATION; QUALITY; PATIENT;
D O I
10.2463/mrms.mp.2023-0016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Hemodynamics is important in the initiation, growth, and rupture of intracranial aneurysms. Since intracranial aneurysms are small, a high -field MR system with high spatial resolution and high SNR is desirable for this hemodynamic analysis. The purpose of this study was to investigate whether the accuracy of MR fluid dynamic (MRFD) results based on 3D phase -contrast MR (3D PC MR, non-electrocardiogram[ECG]-gated 4D Flow MRI) data from a human cerebrovascular phantom and human healthy subjects obtained by a 7T MR system was superior to those by a 3T MR system. Methods: 3D PC MR and 3D time of flight MR angiography (3D TOF MRA) imaging were performed on a 3T MR system and a 7T MR system for a human cerebrovascular phantom and 10 healthy human subjects, and MRFD analysis was performed using these data. The MRFD results from each MR system were then compared with the following items based on the computational fluid dynamics (CFD) results: 3D velocity vector field; correlation coefficient (R), angular similarity index (ASI), and magnitude similarity index (MSI) of blood flow velocity vectors. Results: In the MRFD results of 3D velocity vectors of the cerebrovascular phantom, noise -like vectors were observed near the vascular wall on the 3T MR system, but no noise was observed on the 7T MR system, showing results similar to those of CFD. In the MRFD results of the cerebrovascular phantom and healthy subjects, the correlation coefficients R, ASI, and MSI of the 7T MR system were higher than those of the 3T MR system, and ASI and MSI of healthy human subjects were significantly different between the two systems. Conclusions: The accuracy of high spatial resolution MRFD using the 7T MR system exceeded that of the 3T MR system.
引用
收藏
页码:88 / 102
页数:15
相关论文
共 50 条
  • [31] Feasibility of 3D T1W sequences in contrast-material enhanced MR cisternography at 3T
    Algin, Oktay
    Koc, Ural
    Ayberk, Giyas
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2022, 52 (06) : 1943 - 1949
  • [32] Atherosclerosis of middle cerebral artery: Evaluation with high-resolution MR imaging at 3T
    Li, Ming-li
    Xu, Wei-hai
    Song, Lan
    Feng, Feng
    You, Hui
    Ni, Jun
    Gao, Shan
    Cui, Li-ying
    Jin, Zheng-yu
    ATHEROSCLEROSIS, 2009, 204 (02) : 447 - 452
  • [33] Susceptibility-weighted MR imaging of radiation therapy-induced cerebral microbleeds in patients with glioma: a comparison between 3T and 7T
    Bian, Wei
    Hess, Christopher P.
    Chang, Susan M.
    Nelson, Sarah J.
    Lupo, Janine M.
    NEURORADIOLOGY, 2014, 56 (02) : 91 - 96
  • [34] Multimodal imaging: Simultaneous EEG in a 3T Hybrid MR-PET system
    Neuner, I.
    Warbrick, T.
    Tellmann, L.
    Kops, E. Rota
    Arrubla, J.
    Boers, F.
    Herzog, H.
    Shah, N. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 37 - 38
  • [35] Susceptibility-weighted MR imaging of radiation therapy-induced cerebral microbleeds in patients with glioma: a comparison between 3T and 7T
    Wei Bian
    Christopher P. Hess
    Susan M. Chang
    Sarah J. Nelson
    Janine M. Lupo
    Neuroradiology, 2014, 56 : 91 - 96
  • [36] Simultaneous Head and Spine MR Imaging in Children Using a Dedicated Multichannel Receiver System at 3T
    Li, Nan
    Zheng, Hui
    Xu, Guangzu
    Gui, Ting
    Yin, Qiufeng
    Chen, Qiaoyan
    Lee, Jo
    Xin, Yang
    Zhang, Shuheng
    He, Qiang
    Zhang, Xiaoliang
    Liu, Xin
    Zheng, Hairong
    Wang, Dengbin
    Li, Ye
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (12) : 3659 - 3670
  • [37] High-Resolution Uniform MR Imaging of Finger Joints Using a Dedicated RF Coil at 3T
    Kwok, Wingchi E.
    You, Zhigang
    Monu, Johnny
    Seo, Gwysuk
    Ritchlin, Christopher
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 240 - 247
  • [38] Phased array 3D MR spectroscopic imaging of the brain at 7 T
    Xu, Duan
    Cunningham, Charles H.
    Chen, Albert P.
    Li, Yan
    Kelley, Douglas A. C.
    Mukherjee, Pratik
    Pauly, John M.
    Nelson, Sarah J.
    Vigneron, Daniel B.
    MAGNETIC RESONANCE IMAGING, 2008, 26 (09) : 1201 - 1206
  • [39] Iterative denoising accelerated 3D SPACE FLAIR sequence for brain MR imaging at 3T
    Eliezer, Michael
    Vaussy, Alexis
    Toupin, Solenn
    Barbe, Remy
    Kannengiesser, Stephan
    Stemmer, Alto
    Houdart, Emmanuel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 13 - 20
  • [40] Intracranial vascular stenosis and occlusion: comparison of 3D time-of-flight and 3D phase-contrast MR angiography
    Oelerich, M
    Lentschig, MG
    Zunker, P
    Reimer, P
    Rummeny, EJ
    Schuierer, G
    NEURORADIOLOGY, 1998, 40 (09) : 567 - 573