Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System

被引:0
|
作者
Tajima, Shunsuke [1 ,2 ]
Isoda, Haruo [3 ,4 ]
Fukunaga, Masaki [5 ]
Komori, Yoshiaki [6 ]
Naganawa, Shinji [7 ]
Sadato, Norihiro [5 ,8 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol & Med Lab Sci, Radiol Sci, Nagoya, Aichi, Japan
[2] Nagoya Univ Hosp, Dept Radiol Technol, Nagoya, Aichi, Japan
[3] Nagoya Univ, Brain & Mind Res Ctr, Nagoya, Aichi, Japan
[4] Nagoya Univ, Grad Sch Med, Dept Integrated Hlth Sci, 1-1-20 Daiko Minami,Higashi Ku, Nagoya, Aichi 4618673, Japan
[5] Natl Inst Physiol Sci, Div Cerebral Integrat, Okazaki, Aichi, Japan
[6] Siemens Healthcare KK, Tokyo, Japan
[7] Nagoya Univ, Grad Sch Med, Dept Radiol, Nagoya, Aichi, Japan
[8] Ritsumeikan Univ, Res Org Sci & Technol, Kyoto, Kyoto, Japan
关键词
hemodynamics; intracranial artery; phase-contrast MR imaging; 4D flow MRI; magnetic field strength; UNRUPTURED INTRACRANIAL ANEURYSMS; SUBARACHNOID HEMORRHAGE; SHEAR-STRESS; FLOW; VELOCITY; RUPTURE; RISK; QUANTIFICATION; QUALITY; PATIENT;
D O I
10.2463/mrms.mp.2023-0016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Hemodynamics is important in the initiation, growth, and rupture of intracranial aneurysms. Since intracranial aneurysms are small, a high -field MR system with high spatial resolution and high SNR is desirable for this hemodynamic analysis. The purpose of this study was to investigate whether the accuracy of MR fluid dynamic (MRFD) results based on 3D phase -contrast MR (3D PC MR, non-electrocardiogram[ECG]-gated 4D Flow MRI) data from a human cerebrovascular phantom and human healthy subjects obtained by a 7T MR system was superior to those by a 3T MR system. Methods: 3D PC MR and 3D time of flight MR angiography (3D TOF MRA) imaging were performed on a 3T MR system and a 7T MR system for a human cerebrovascular phantom and 10 healthy human subjects, and MRFD analysis was performed using these data. The MRFD results from each MR system were then compared with the following items based on the computational fluid dynamics (CFD) results: 3D velocity vector field; correlation coefficient (R), angular similarity index (ASI), and magnitude similarity index (MSI) of blood flow velocity vectors. Results: In the MRFD results of 3D velocity vectors of the cerebrovascular phantom, noise -like vectors were observed near the vascular wall on the 3T MR system, but no noise was observed on the 7T MR system, showing results similar to those of CFD. In the MRFD results of the cerebrovascular phantom and healthy subjects, the correlation coefficients R, ASI, and MSI of the 7T MR system were higher than those of the 3T MR system, and ASI and MSI of healthy human subjects were significantly different between the two systems. Conclusions: The accuracy of high spatial resolution MRFD using the 7T MR system exceeded that of the 3T MR system.
引用
收藏
页码:88 / 102
页数:15
相关论文
共 50 条
  • [11] Hemodynamic Changes in Patients with Arteriovenous Malformations Assessed Using High-Resolution 3D Radial Phase-Contrast MR Angiography
    Chang, W.
    Loecher, M. W.
    Wu, Y.
    Niemann, D. B.
    Ciske, B.
    Aagaard-Kienitz, B.
    Kecskemeti, S.
    Johnson, K. M.
    Wieben, O.
    Mistretta, C.
    Turski, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (08) : 1565 - 1572
  • [12] High-Resolution 3T MR Neurography of the Brachial Plexus and Its Branches, with Emphasis on 3D Imaging
    Chhabra, A.
    Thawait, G. K.
    Soldatos, T.
    Thakkar, R. S.
    Del Grande, F.
    Chalian, M.
    Carrino, J. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) : 486 - 497
  • [13] High-resolution imaging at 3T and 7T with multiring local volume coils
    Fakhereh Mirrashed
    Jonathan C. Sharp
    Iva Cheung
    Boguslaw Tomanek
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 167 - 173
  • [14] Normal Pituitary Stalk: High-Resolution MR Imaging at 3T
    Satogami, N.
    Miki, Y.
    Koyama, T.
    Kataoka, M.
    Togashi, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (02) : 355 - 359
  • [15] High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex
    von Borstel, Donald
    Wang, Michael
    Small, Kirstin
    Nozaki, Taiki
    Yoshioka, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (01) : 3 - 15
  • [16] High-resolution imaging at 3T and 7T with multiring local volume coils
    Mirrashed, F
    Sharp, JC
    Cheung, I
    Tomanek, B
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (04) : 167 - 173
  • [17] 3D sensitivity encoded ellipsoidal MR spectroscopic imaging of gliomas at 3T
    Ozturk-Isik, Esin
    Chen, Albert. P.
    Crane, Jason C.
    Bian, Wei
    Xu, Duan
    Han, Eric T.
    Chang, Susan M.
    Vigneron, Daniel B.
    Nelson, Sarah J.
    MAGNETIC RESONANCE IMAGING, 2009, 27 (09) : 1249 - 1257
  • [18] Comparing the spatial integrity of 7T and 3T MR images for image-guided radiotherapy of brain tumors
    Peerlings, J.
    Compter, I.
    Janssen, F. M.
    Wiggins, C. J.
    Mottaghy, F. M.
    Lambin, P.
    Hoffmann, A. L.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S492 - S493
  • [19] Carotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T
    Platzek, Ivan
    Sieron, Dominik
    Wiggermann, Philipp
    Laniado, Michael
    RADIOLOGY RESEARCH AND PRACTICE, 2014, 2014
  • [20] 3D MR thermometry of frozen tissue: Feasibility and accuracy during cryoablation at 3T
    Overduin, Christiaan G.
    Futterer, Jurgen J.
    Scheenen, Tom W. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (06) : 1572 - 1579